• United States

Research Output 1974 2020

161 Citations (Scopus)

Design Strategies and Applications of Tissue Bioadhesives

Mehdizadeh, M. & Yang, J., Mar 1 2013, In : Macromolecular Bioscience. 13, 3, p. 271-288 18 p.

Research output: Contribution to journalArticle

Tissue Adhesives
Tissue
Adhesives
Regenerative Medicine
Sealants
48 Citations (Scopus)

Design strategies for fluorescent biodegradable polymeric biomaterials

Zhang, Y. & Yang, J., Jan 14 2013, In : Journal of Materials Chemistry B. 1, 2, p. 132-148 17 p.

Research output: Contribution to journalArticle

Biodegradable polymers
Biocompatible Materials
Biomaterials
Polymers
Imaging techniques
87 Citations (Scopus)

Desorption - Ionization mass spectrometry using deposited nanostructured silicon films

Cuiffi, J. D., Hayes, D. J., Fonash, S. J., Brown, K. N. & Jones, A. D., Mar 15 2001, In : Analytical chemistry. 73, 6, p. 1292-1295 4 p.

Research output: Contribution to journalArticle

Silicon
Ionization
Mass spectrometry
Desorption
Purification
28 Citations (Scopus)
Pulsatile Flow
Embolism
Cardiopulmonary Bypass
Flow rate
Pumps
2 Citations (Scopus)

Detection of culture-negative sepsis in clinical blood samples using a microfluidic assay for combined CD64 and CD69 cell capture

Zhou, Y., Zhang, Y., Johnson, A., Venable, A., Griswold, J. & Pappas, D., Jul 25 2019, In : Analytica Chimica Acta. 1062, p. 110-117 8 p.

Research output: Contribution to journalArticle

Microfluidics
Assays
Sepsis
Blood
blood
1 Citation (Scopus)

Detection of plasma proteins in multicomponent protein films by atomic force microscopy

Siedlecki, C., Agnihotri, A., Rice, Z. & Soman, P., Aug 1 2006, In : Microscopy and Microanalysis. 12, SUPPL. 2, p. 34-35 2 p.

Research output: Contribution to journalArticle

Atomic force microscopy
fibrinogen
atomic force microscopy
proteins
Proteins
10 Citations (Scopus)

Detection of sepsis in patient blood samples using CD64 expression in a microfluidic cell separation device

Zhang, Y., Li, W., Zhou, Y., Johnson, A., Venable, A., Hassan, A., Griswold, J. & Pappas, D., Jan 7 2018, In : Analyst. 143, 1, p. 241-249 9 p.

Research output: Contribution to journalArticle

Open Access
Microfluidics
Cell Separation
Sepsis
Blood
blood

Detection of simulated microemboli using a diffraction grating ultrasound probe and spectral energy criteria

Ballakur, S. G., Blebea, J., Hazard, S. W., Zickler, R. & Weiss, W., 2002, Bioengineering, Proceedings of the Northeast Conference. Moxon, K., Sherif, D. E. & Kanakasabai, S. (eds.). p. 163-164 2 p.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Diffraction gratings
Linear regression
Ultrasonics

Detection of simulated microemboli using a diffraction grating ultrasound probe and spectral energy criteria

Ballakur, S. G., Blebea, J., Hazard, S. W., Zickler, R. & Weiss, W., Jan 1 2002, Proceedings of the IEEE 28th Annual Northeast Bioengineering Conference, NEBC 2002. El-Sherif, D., Moxon, K. & Kanakasabai, S. (eds.). Institute of Electrical and Electronics Engineers Inc., p. 163-164 2 p. 999516. (Proceedings of the IEEE Annual Northeast Bioengineering Conference, NEBEC; vol. 2002-January).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Diffraction gratings
Signal processing
Ultrasonics
5 Citations (Scopus)

Determinants of microvascular blood flow.

Lipowsky, H. H., Aug 1 1982, In : Physiologist. 25, 4, p. 357-363 7 p.

Research output: Contribution to journalArticle

Microcirculation
Blood Viscosity
Blood Flow Velocity
Hematocrit
Vascular Resistance

Determination and pharmacokinetics and bioavailability of O-demethyl nuciferine in mice by UPLC–MS/MS

Wu, H., Lu, M., He, J., Huang, M., Zheng, A., Zhang, M., Wen, C. & Ye, J., Jan 1 2019, In : Acta Chromatographica. 31, 3, p. 222-227 6 p.

Research output: Contribution to journalArticle

Open Access
Pharmacokinetics
formic acid
Blood
Mass spectrometers
Diazepam

Determination of hematocrit from mean transit time of red blood cells and plasma in cremaster muscle of the rat

Cram, L. & Lipowsky, H. H., 1990, Bioengineering, Proceedings of the Northeast Conference. Gaumond, R. P. (ed.). Publ by IEEE, p. 147-148 2 p.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Muscle
Rats
Blood
Cells
Plasmas
2 Citations (Scopus)

Determination of Reynolds Shear Stress Level for Hemolysis

Jhun, C. S., Stauffer, M. A., Reibson, J. D., Yeager, E. E., Newswanger, R. K., Taylor, J. O., Manning, K. B., Weiss, W. J. & Rosenberg, G., Jan 1 2018, In : ASAIO journal (American Society for Artificial Internal Organs : 1992). 64, 1, p. 63-69 7 p.

Research output: Contribution to journalArticle

Hemolysis
Shear stress
Hemoglobin
Hemoglobins
Blood
10 Citations (Scopus)

Determining arterial pressure, left atrial pressure and cardiac output from the left pneumatic drive line of the total artificial heart

Rosenberg, G., Landis, D. L., Phillips, W. M., Stallsmith, J. & Pierce, W. S., Jan 1 1978, In : Transactions - American Society for Artificial Internal Organs. 24, 1, p. 341-344 4 p.

Research output: Contribution to journalArticle

Artificial Heart
Atrial Pressure
Cardiac Output
Arterial Pressure
Blood Pressure
24 Citations (Scopus)

Determining β 2-integrin and intercellular adhesion molecule 1 binding kinetics in tumor cell adhesion to leukocytes and endothelial cells by a gas-driven micropipette assay

Fu, C., Tong, C., Wang, M., Gao, Y., Zhang, Y., Lü, S., Liang, S., Dong, C. & Long, M., Oct 7 2011, In : Journal of Biological Chemistry. 286, 40, p. 34777-34787 11 p.

Research output: Contribution to journalArticle

Cell adhesion
Endothelial cells
Intercellular Adhesion Molecule-1
Cell Adhesion
Integrins
38 Citations (Scopus)

Determinstic lateral displacement MEMS device for continuous blood cell separation

Zheng, S., Yung, R., Tai, Y. C. & Kasdan, H., Oct 25 2005, In : Proceedings of the IEEE International Conference on Micro Electro Mechanical Systems (MEMS). p. 851-854 4 p.

Research output: Contribution to journalConference article

blood cells
leukocytes
microelectromechanical systems
MEMS
Blood
58 Citations (Scopus)

Development and Application of Stable Phantoms for the Evaluation of Photoacoustic Imaging Instruments

Bohndiek, S. E., Bodapati, S., Van De Sompel, D., Kothapalli, S. R. & Gambhir, S. S., Sep 25 2013, In : PloS one. 8, 9, e75533.

Research output: Contribution to journalArticle

Photoacoustic effect
image analysis
Imaging techniques
Quality Control
Imaging Phantoms
5 Citations (Scopus)

Development and Current Status of a Total Artificial Heart

Magovern, J. A., Rosenberg, G. & Pierce, W. S., Jan 1 1986, In : Artificial organs. 10, 5, p. 357-363 7 p.

Research output: Contribution to journalArticle

Artificial heart
Artificial Heart
Electricity
Hemodynamics
Goats
3 Citations (Scopus)
Compliance
38 Citations (Scopus)

Development and validation of a computational fluid dynamics methodology for simulation of pulsatile left ventricular assist devices

Medvitz, R. B., Kreider, J. W., Manning, K. B., Fontaine, A. A., Deutsch, S. & Paterson, E. G., Mar 1 2007, In : ASAIO Journal. 53, 2, p. 122-131 10 p.

Research output: Contribution to journalArticle

Left ventricular assist devices
Heart-Assist Devices
Hydrodynamics
Velocity measurement
Pulsatile flow
1 Citation (Scopus)

DEVELOPMENT AND VERIFICATION OF EVAD/MOCK LOOP SYSTEM MODEL.

Fikse, T. H., Rosenberg, G., Snyder, A. J., Landis, D. L., Hanson, K. L., Kern, S. E., Geselowitz, D. B. & Pierce, W. S., 1984, IEEE/Engineering in Medicine and Biology Society Annual Conference. Semmlow, J. L. & Welkowitz, W. (eds.). IEEE, p. 33-37 5 p.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Electric motors
Mechanical drives
Blood
Hydraulics
Pumps
98 Citations (Scopus)

Development of 17O NMR approach for fast imaging of cerebral metabolic rate of oxygen in rat brain at high field

Zhu, X. H., Zhang, Y., Tian, R. X., Lei, H., Zhang, N., Zhang, X., Merkle, H., Ugurbil, K. & Chen, W., Oct 1 2002, In : Proceedings of the National Academy of Sciences of the United States of America. 99, 20, p. 13194-13199 6 p.

Research output: Contribution to journalArticle

Magnetic Resonance Imaging
Oxygen
Brain
Inhalation
Chloralose
Stroke
Acute
Computational Model
Cohesive Zone
Cohesive Zone Model
19 Citations (Scopus)

Development of a computational model for macroscopic predictions of device-induced thrombosis

Taylor, J. O., Meyer, R. S., Deutsch, S. & Manning, K. B., Dec 1 2016, In : Biomechanics and Modeling in Mechanobiology. 15, 6, p. 1713-1731 19 p.

Research output: Contribution to journalArticle

Thrombosis
Computational Model
Equipment and Supplies
Wall Shear Stress
Prediction
19 Citations (Scopus)

Development of a device for measuring adherence of skin grafts to the wound surface

Dong, C., Mead, E., Skalak, R., Fung, Y. C., Debes, J. C., Zapata-Sirvent, R. L., Andree, C., Greenleaf, G., Cooper, M. & Hansbrough, J. F., Jan 1 1993, In : Annals of Biomedical Engineering. 21, 1, p. 51-55 5 p.

Research output: Contribution to journalArticle

Grafts
Skin
Peeling
Substrates
Adhesives
8 Citations (Scopus)

Development of a Dual-Functional Hydrogel Using RGD and Anti-VEGF Aptamer

Zhao, N., Battig, M. R., Xu, M., Wang, X., Xiong, N. & Wang, Y., Nov 2017, In : Macromolecular Bioscience. 17, 11, 1700201.

Research output: Contribution to journalArticle

Hydrogel
Biocompatible Materials
Biomaterials
Hydrogels
Vascular Endothelial Growth Factor A

Development of a long-term electric motor left ventricular assist system

Gaines, W. E., Rosenberg, G., Pennock, J. L. & Pierce, W. S., Jan 1 1984, In : Heart Transplantation. 3, 4, p. 323-328 6 p.

Research output: Contribution to journalArticle

1 Citation (Scopus)

Development of an artificial organ design course

Zapanta, C. & Manning, K. B., Jan 1 2006, In : ASEE Annual Conference and Exposition, Conference Proceedings.

Research output: Contribution to journalConference article

Artificial organs
Neural prostheses
Heart valve prostheses
Oxygenators
Codes (standards)

Development of an implantable electric motor artificial heart

Richenbacher, W. E., Rosenberg, G. & Landis, D. L., Jan 1 1983, In : Surgical Forum. VOL. 34, p. 250-252 3 p.

Research output: Contribution to journalArticle

Artificial Heart
17 Citations (Scopus)

Development of an inlet pressure sensor for control in a left ventricular assist device

Fritz, B., Cysyk, J., Newswanger, R., Weiss, W. & Rosenberg, G., May 1 2010, In : ASAIO Journal. 56, 3, p. 180-185 6 p.

Research output: Contribution to journalArticle

Left ventricular assist devices
Heart-Assist Devices
Pressure sensors
Pressure
Step response
10 Citations (Scopus)

Development of a novel pretargeting system with bifunctional nucleic acid molecules

Zhou, J., Soontornworajit, B., Snipes, M. P. & Wang, Y., Aug 28 2009, In : Biochemical and Biophysical Research Communications. 386, 3, p. 521-525 5 p.

Research output: Contribution to journalArticle

Nucleic Acids
Molecules
Oligonucleotides
Labeling

Development of a Pain Scoring System for Use in Sheep Surgically Implanted with Ventricular Assist Devices

Izer, J. M., LaFleur, R. A., Weiss, W. J. & Wilson, R. P., Nov 17 2019, In : Journal of Investigative Surgery. 32, 8, p. 706-715 10 p.

Research output: Contribution to journalArticle

Heart-Assist Devices
Sheep
Pain
Postoperative Pain
Biomedical Research
5 Citations (Scopus)

Development of a platelet adhesion transport equation for a computational thrombosis model

Taylor, J. O., Yang, L., Deutsch, S. & Manning, K. B., Jan 4 2017, In : Journal of Biomechanics. 50, p. 114-120 7 p.

Research output: Contribution to journalArticle

Platelets
Thrombosis
Blood Platelets
Adhesion
Biocompatible Materials
40 Citations (Scopus)

Development of a side-view chamber for studying cell-surface adhesion under flow conditions

Cao, J., Usami, S. & Dong, C., Jan 1 1997, In : Annals of Biomedical Engineering. 25, 3, p. 573-580 8 p.

Research output: Contribution to journalArticle

Adhesion
Channel flow
Adhesives
Molecules
Bond strength (materials)

Development of a wavelet analytical tool for isolating and evaluating cavitation-induced hemolysis generated during mechanical heart valve closure

Herbertson, L. H., Deutsch, S. & Manning, K. B., Dec 1 2007, Proceedings of the ASME Summer Bioengineering Conference 2007, SBC 2007. p. 139-140 2 p. (Proceedings of the ASME Summer Bioengineering Conference 2007, SBC 2007).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Cavitation
Hydrophones
Wavelet analysis
Blood
Acoustics

Development of brain-wide connectivity architecture in awake rats

Ma, Z., Ma, Y. & Zhang, N., Aug 1 2018, In : NeuroImage. 176, p. 380-389 10 p.

Research output: Contribution to journalArticle

Brain
Communication
Cerebral Dominance
Neuroanatomy
Cluster Analysis
6 Citations (Scopus)

Development of Citrate-Based Dual-Imaging Enabled Biodegradable Electroactive Polymers

Shan, D., Kothapalli, S. R., Ravnic, D. J., Gerhard, E., Kim, J. P., Guo, J., Ma, C., Guo, J., Gui, L., Sun, L., Lu, D. & Yang, J., Aug 22 2018, In : Advanced Functional Materials. 28, 34, 1801787.

Research output: Contribution to journalArticle

electroactive polymers
citrates
Citric Acid
Polymers
Photoacoustic effect
4 Citations (Scopus)
Artificial heart
Artificial Heart
Rheology
Velocity measurement
Flow fields
19 Citations (Scopus)

Development of injectable citrate-based bioadhesive bone implants

Xie, D., Guo, J., Mehdizadeh, M. R., Tran, R. T., Chen, R., Sun, D., Qian, G., Jin, D., Bai, X. & Yang, J., Jan 21 2015, In : Journal of Materials Chemistry B. 3, 3, p. 387-398 12 p.

Research output: Contribution to journalArticle

Citric Acid
Bone
Durapatite
Hydroxyapatite
Tissue
40 Citations (Scopus)

Development of intrinsically photoluminescent and photostable polylactones

Xie, Z., Zhang, Y., Liu, L., Weng, H., Mason, R. P., Tang, L., Nguyen, K. T., Hsieh, J. T. & Yang, J., Jul 9 2014, In : Advanced Materials. 26, 26, p. 4491-4496 6 p.

Research output: Contribution to journalArticle

Biodegradable polymers
Drug delivery
Nanoparticles
Imaging techniques
Degradation
1 Citation (Scopus)

Development of microwave and impedance spectroscopy methods for in-situ nondestructive evaluation of alkali silica reaction in concrete

Heifetz, A., Bakhtiari, S., Lu, J., Aranson, I. S., Vinokur, V. M. & Bentivegna, A. F., Feb 16 2017, 43rd Annual Review of Progress in Quantitative Nondestructive Evaluation, Volume 36. Bond, L. J. & Chimenti, D. E. (eds.). American Institute of Physics Inc., 120003. (AIP Conference Proceedings; vol. 1806).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

alkalies
impedance
silicon dioxide
microwaves
evaluation
10 Citations (Scopus)

Development of novel submicron textured polyether(urethane urea) for decreasing platelet adhesion

Milner, K. R., Siedlecki, C. & Snyder, A. J., Sep 1 2005, In : ASAIO Journal. 51, 5, p. 578-584 7 p.

Research output: Contribution to journalArticle

Polyethers
Platelets
Urea
Blood Platelets
Adhesion
1 Citation (Scopus)

Development of osteopromotive poly (octamethylene citrate glycerophosphate) for enhanced bone regeneration

He, Y., Li, Q., Ma, C., Xie, D., Li, L., Zhao, Y., Shan, D., Chomos, S. K., Dong, C., Tierney, J. W., Sun, L., Lu, D., Gui, L. & Yang, J., Jul 15 2019, In : Acta Biomaterialia. 93, p. 180-191 12 p.

Research output: Contribution to journalArticle

Glycerophosphates
Bone Regeneration
Citric Acid
Durapatite
Hydroxyapatite
3 Citations (Scopus)

Development of Photoactivated Fluorescent N-Hydroxyoxindoles and Their Application for Cell-Selective Imaging

Lai, J., Yu, A., Yang, L., Zhang, Y., Shah, B. P. & Lee, K. B., Apr 25 2016, In : Chemistry - A European Journal. 22, 18, p. 6361-6367 7 p.

Research output: Contribution to journalArticle

Ethanol
Fluorophores
Imaging techniques
Stem cells
Fluorescence
17 Citations (Scopus)

Development of tannin-inspired antimicrobial bioadhesives

Guo, J., Sun, W., Kim, J. P., Lu, X., Li, Q., Lin, M., Mrowczynski, O., Rizk, E. B., Cheng, J., Qian, G. & Yang, J., May 2018, In : Acta Biomaterialia. 72, p. 35-44 10 p.

Research output: Contribution to journalArticle

Tannins
Tissue
Acids
Silver
Gelatin
1 Citation (Scopus)

Device specific aortic outflow cannula jets studied using 2D PIV and high-performance 3D CFD simulation

Menon, P. G., Teslovich, N., Chen, C. Y., Sotiropoulos, F., Undar, A. & Pekkan, K., Dec 1 2012, ASME 2012 Summer Bioengineering Conference, SBC 2012. p. 67-68 2 p. (ASME 2012 Summer Bioengineering Conference, SBC 2012).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Computational fluid dynamics
Acrylonitrile
Pediatrics
Styrene
Butadiene
19 Citations (Scopus)

Diaphragm Motion Affects Flow Patterns in an Artificial Heart

Hochareon, P., Manning, K. B., Fontaine, A. A., Deutsch, S. & Tarbell, J. M., Dec 1 2003, In : Artificial organs. 27, 12, p. 1102-1109 8 p.

Research output: Contribution to journalArticle

Artificial heart
Artificial Heart
Diaphragms
Diaphragm
Flow patterns
2 Citations (Scopus)

Diazeniumdiolation of protamine sulfate reverses mitogenic effects on smooth muscle cells and fibroblasts

Van Lith, R., Yang, J. & Ameer, G. A., May 2015, In : Free Radical Biology and Medicine. 82, p. 13-21 9 p.

Research output: Contribution to journalArticle

Protamines
Fibroblasts
Smooth Muscle Myocytes
Muscle
Cells
2 Citations (Scopus)
Pulsatile Flow
Pulsatile flow
Blood pressure
Terminology
Coronary Artery Bypass
90 Citations (Scopus)

Dielectrophoretic assembly and integration of nanowire devices with functional CMOS operating circuitry

Evoy, S., DiLello, N., Deshpande, V., Narayanan, A., Liu, H., Riegelman, M., Martin, B. R., Hailer, B., Bradley, J. C., Weiss, W., Mayer, T. S., Gogotsi, Y., Bau, H. H., Mallouk, T. E. & Raman, S., Jul 1 2004, In : Microelectronic Engineering. 75, 1, p. 31-42 12 p.

Research output: Contribution to journalConference article

Nanowires
CMOS
nanowires
assembly
Nanosensors