• United States

Fingerprint Dive into the research topics where Children's Heart Group is active. These topic labels come from the works of this organization's members. Together they form a unique fingerprint.

Pediatrics Engineering & Materials Science
Pulsatile Flow Medicine & Life Sciences
Cardiopulmonary Bypass Medicine & Life Sciences
Hemodynamics Medicine & Life Sciences
Extracorporeal Membrane Oxygenation Medicine & Life Sciences
Perfusion Medicine & Life Sciences
Pulsatile flow Engineering & Materials Science
Pumps Engineering & Materials Science

Network Recent external collaboration on country level. Dive into details by clicking on the dots.

Research Output 1985 2019

1 Citation (Scopus)

Chronic In Vivo Test of a Right Heart Replacement Blood Pump for Failed Fontan Circulation

Cysyk, J., Clark, J. B., Newswanger, R., Jhun, C-S., Izer, J., Finicle, H., Reibson, J., Doxtater, B., Weiss, W. & Rosenberg, G., Aug 1 2019, In : ASAIO journal (American Society for Artificial Internal Organs : 1992). 65, 6, p. 593-600 8 p.

Research output: Contribution to journalArticle

Superior Vena Cava
Venous Pressure
Inferior Vena Cava
Blood
Right Heart Bypass

Chronic Ovine Studies Demonstrate Low Thromboembolic Risk in the Penn State Infant Ventricular Assist Device

Lukic, B., Clark, J., Izer, J., Cooper, T. K., Finicle, H. A., Cysyk, J., Doxtater, B., Yeager, E., Reibson, J., Newswanger, R. K., Leibich, P., Bletcher, K. & Weiss, W., May 1 2019, In : ASAIO journal (American Society for Artificial Internal Organs : 1992). 65, 4, p. 371-379 9 p.

Research output: Contribution to journalArticle

Heart-Assist Devices
Sheep
Animals
Equipment and Supplies
Left ventricular assist devices
Extracorporeal Membrane Oxygenation
Pediatrics
Health
Registries
Networks (circuits)
Pulmonary Valve Insufficiency
Aortic Valve
Pediatrics
3 Citations (Scopus)

Effects of Pulsatile Control Algorithms for Diagonal Pump on Hemodynamic Performance and Hemolysis

Wang, S., Force, M., Moroi, M. K., Patel, S., Kunselman, A. & Undar, A., Jan 1 2019, In : Artificial organs. 43, 1, p. 60-75 16 p.

Research output: Contribution to journalArticle

Hemodynamics
Hemolysis
Pumps
Pediatrics
Oxygenators
1 Citation (Scopus)
Pulsatile Flow
Pulsatile flow
Extracorporeal Membrane Oxygenation
Hemodynamics
Thigh
4 Citations (Scopus)

Hemodynamic Evaluation of Avalon Elite Bi-Caval Dual Lumen Cannulas and Femoral Arterial Cannulas

Wang, S., Force, M., Kunselman, A., Palanzo, D., Brehm, C. & Undar, A., Jan 1 2019, In : Artificial organs. 43, 1, p. 41-53 13 p.

Research output: Contribution to journalArticle

Venae Cavae
Hemodynamics
Thigh
Networks (circuits)
Extracorporeal Membrane Oxygenation
1 Citation (Scopus)

Impact of cannula size and line length on venous line pressure in pediatric VA-/VV-ECLS circuits

Wang, S., Kunselman, A. & Undar, A., Jan 1 2019, In : Artificial organs. 43, 8, p. E165-E177

Research output: Contribution to journalArticle

Pediatrics
Venous Pressure
Extracorporeal Membrane Oxygenation
Networks (circuits)
Tubing

Impact of Heart Rate on Pulsatile Hemodynamic Performance in a Neonatal ECG-Synchronized ECLS System

Wang, S., Moroi, M. K., Force, M., Kunselman, A. & Undar, A., Jan 1 2019, In : Artificial organs. 43, 1, p. 81-89 9 p.

Research output: Contribution to journalArticle

Hemodynamics
Pulsatile Flow
Pulsatile flow
Electrocardiography
Heart Rate