• 500 University Dr.

    17033 Hershey

    United States

Research Output 1975 2020

Filter
Conference contribution
1988
2 Citations (Scopus)

Permanent left ventricular assist device: In vivo testing

Rosenberg, G., Snyder, A. J., Weiss, W., Cleary, T. J. & Pierce, W. S., Nov 1988, IEEE/Engineering in Medicine and Biology Society Annual Conference. pt 1 ed. Publ by IEEE, Vol. 10. p. 65-67 3 p.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Left ventricular assist devices
Animals
Blood
Brushless DC motors
Polysulfones
1987

POWER REQUIREMENTS FOR AN ELECTRIC MOTOR-DRIVEN TOTAL ARTIFICIAL HEART.

Rosenberg, G., Snyder, A. J., Weiss, W., Pierce, W. S. & Geselowitz, D. B., 1987, IEEE/Engineering in Medicine and Biology Society Annual Conference. IEEE, p. 188-189 2 p.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Artificial heart
Electric motors
Pumps
Blood
Rollers (machine components)
1 Citation (Scopus)

TELEMETRY SYSTEM FOR THE IMPLANTED TOTAL ARTIFICIAL HEART AND VENTRICULAR ASSIST DEVICE.

Weiss, W., Gibbons, P. J., Gaumond, R. P., Snyder, A. J., Rosenberg, G. & Pierce, W. S., 1987, IEEE/Engineering in Medicine and Biology Society Annual Conference. IEEE, p. 186-187 2 p.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Artificial heart
Telemetering
Electric motors
Power transmission
Clocks
1986
1 Citation (Scopus)

DRIVE SYSTEM TO POWER PNEUMATIC BLOOD PUMPS.

Waldhausen, G., Weiss, W., Rosenberg, G., Landis, D., Cleary, T. & Pierce, W. S., 1986, Unknown Host Publication Title. ASME, p. 174-175 2 p.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Pneumatics
Blood
Pumps
Artificial heart
Control systems

MODIFICATION OF A SERIES-TUNED TRANSCUTANEOUS ENERGY TRANSMISSION SYSTEM.

Gaumond, R. P., Geselowitz, D. B., Gibbons, P., Trumble, D. & Weiss, W., 1986, Unknown Host Publication Title. IEEE, p. 3-6 4 p.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Shielding
Telecommunication links
Control systems

TESTING AND CHARACTERIZING A PORTABLE POWER SOURCE FOR THE ELECTRIC ARTIFICIAL HEART.

Kloss, D. A., Roehm, E. A., Snyder, A. J., Rosenberg, G. & Pierce, W. S., 1986, IEEE/Engineering in Medicine and Biology Society Annual Conference. IEEE, p. 65-68 4 p.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Artificial heart
Testing
1985
1 Citation (Scopus)

FLOW OF NEWTONIAN AND NON-NEWTONIAN BLOOD ANALOGS IN A TAH.

Mann, K. A., Deutsch, S., Tarbell, J. M., Geselowitz, D. B., Rosenberg, G. & Pierce, W. S., 1985, IEEE/Engineering in Medicine and Biology Society Annual Conference. Lin, J. C. & Feinberg, B. N. (eds.). IEEE, p. 790-793 4 p.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Artificial heart
Velocimeters
Flow structure
Polymer solutions
Glycerol

MICROPROCESSOR-BASED FEEDBACK CONTROL SYSTEM FOR THE PENN STATE EVAD.

Hanson, K. L., Tsach, U., Kern, S. E., Geselowitz, D. B., Rosenberg, G. & Pierce, W. S., 1985, IEEE/Engineering in Medicine and Biology Society Annual Conference. Lin, J. C. & Feinberg, B. N. (eds.). IEEE, p. 786-789 4 p.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Feedback control
Microprocessor chips
Control systems
Velocity control
Controllers

TRANSMISSION OF WATER THROUGH A BIOCOMPATIBLE POLYURETHANE - APPLICATION TO CIRCULATORY ASSIST DEVICES.

Reid, J., Rosenberg, G. & Pierce, W. S., 1985, Transactions of the Annual Meeting of the Society for Biomaterials in conjunction with the Interna. Soc for Biomaterials, Vol. 8. p. 56 1 p.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Polyurethanes
Water
Blood
Left ventricular assist devices
Artificial heart
2 Citations (Scopus)

USE OF AN OBSERVER FOR CONTROL OF A TAH.

Kern, S. E., Tsach, U., Hanson, K. L., Geselowitz, D. B., Rosenberg, G. & Pierce, W. S., 1985, IEEE/Engineering in Medicine and Biology Society Annual Conference. Lin, J. C. & Feinberg, B. N. (eds.). IEEE, p. 799-803 5 p.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Artificial heart
Pumps
Velocity control
Computer simulation
1984
1 Citation (Scopus)

DEVELOPMENT AND VERIFICATION OF EVAD/MOCK LOOP SYSTEM MODEL.

Fikse, T. H., Rosenberg, G., Snyder, A. J., Landis, D. L., Hanson, K. L., Kern, S. E., Geselowitz, D. B. & Pierce, W. S., 1984, IEEE/Engineering in Medicine and Biology Society Annual Conference. Semmlow, J. L. & Welkowitz, W. (eds.). IEEE, p. 33-37 5 p.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Electric motors
Mechanical drives
Blood
Hydraulics
Pumps
1983

IN VIVO EXPERIENCE USING A MOTOR-DRIVEN HEART ASSIST PUMP WITH IMPLANTED COMPLIANCE CHAMBER.

Rosenberg, G., Weiss, W., Landis, D. L., Donachy, J. H., Snyder, A. J., Wisman, C. B., Geselowitz, D. B. & Pierce, W. S., 1983, Unknown Host Publication Title. Gerhard, G. C. & Miller, W. T. (eds.). IEEE, p. 438-441 4 p.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Pumps
Compliance
1982
3 Citations (Scopus)

ELECTRIC POWER DRIVEN TOTAL ARTIFICIAL HEART.

Rosenberg, G., Snyder, A. J., Weiss, W., Landis, D. L., Pierce, W. S., Greathouse, S. L., Ostroff, A. H. & Geselowitz, D. B., 1982, IEEE/Engineering in Medicine and Biology Society Annual Conference. IEEE, p. 111-116 6 p.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Artificial heart