• 4465 Citations
  • 33 h-Index
19962019
If you made any changes in Pure, your changes will be visible here soon.

Research Output 1996 2019

Filter
Article
2019
Extracorporeal Membrane Oxygenation
Pediatrics
Health
Registries
Networks (circuits)
3 Citations (Scopus)

Effects of Pulsatile Control Algorithms for Diagonal Pump on Hemodynamic Performance and Hemolysis

Wang, S., Force, M., Moroi, M. K., Patel, S., Kunselman, A. & Undar, A., Jan 1 2019, In : Artificial organs. 43, 1, p. 60-75 16 p.

Research output: Contribution to journalArticle

Hemodynamics
Hemolysis
Pumps
Pediatrics
Oxygenators
1 Citation (Scopus)
Extracorporeal Membrane Oxygenation
Pediatrics
Oxygenation
Hemodynamics
Blood
1 Citation (Scopus)
Pulsatile Flow
Pulsatile flow
Extracorporeal Membrane Oxygenation
Hemodynamics
Thigh
4 Citations (Scopus)

Hemodynamic Evaluation of Avalon Elite Bi-Caval Dual Lumen Cannulas and Femoral Arterial Cannulas

Wang, S., Force, M., Kunselman, A., Palanzo, D., Brehm, C. & Undar, A., Jan 1 2019, In : Artificial organs. 43, 1, p. 41-53 13 p.

Research output: Contribution to journalArticle

Venae Cavae
Hemodynamics
Thigh
Networks (circuits)
Extracorporeal Membrane Oxygenation
1 Citation (Scopus)

Impact of cannula size and line length on venous line pressure in pediatric VA-/VV-ECLS circuits

Wang, S., Kunselman, A. & Undar, A., Jan 1 2019, In : Artificial organs. 43, 8, p. E165-E177

Research output: Contribution to journalArticle

Pediatrics
Venous Pressure
Extracorporeal Membrane Oxygenation
Networks (circuits)
Tubing

Impact of Heart Rate on Pulsatile Hemodynamic Performance in a Neonatal ECG-Synchronized ECLS System

Wang, S., Moroi, M. K., Force, M., Kunselman, A. & Undar, A., Jan 1 2019, In : Artificial organs. 43, 1, p. 81-89 9 p.

Research output: Contribution to journalArticle

Hemodynamics
Pulsatile Flow
Pulsatile flow
Electrocardiography
Heart Rate
1 Citation (Scopus)
Oxygenators
Vascular Access Devices
Vacuum
Cardiopulmonary Bypass
Drainage
2018
5 Citations (Scopus)

Evaluation and Comparison of Hemodynamic Performance of Three ECLS Systems in a Simulated Adult Cardiogenic Shock Model

Undar, A., Wang, S., Moroi, M., Kunselman, A. & Brehm, C., Aug 1 2018, In : Artificial organs. 42, 8, p. 776-785 10 p.

Research output: Contribution to journalArticle

Oxygenators
Cardiogenic Shock
Hemodynamics
Pulsatile Flow
Pulsatile flow
2 Citations (Scopus)

Evaluation of Combined Extracorporeal Life Support and Continuous Renal Replacement Therapy on Hemodynamic Performance and Gaseous Microemboli Handling Ability in a Simulated Neonatal ECLS System

Shank, K. R., Profeta, E., Wang, S., O'Connor, C., Kunselman, A., Woitas, K., Myers, J. & Undar, A., Apr 1 2018, In : Artificial Organs. 42, 4, p. 365-376 12 p.

Research output: Contribution to journalArticle

Life Support Systems
Extracorporeal Membrane Oxygenation
Renal Replacement Therapy
Hemodynamics
Oxygenators
6 Citations (Scopus)

Evaluation of Hemodynamic Performance of a Combined ECLS and CRRT Circuit in Seven Positions With a Simulated Neonatal Patient

Profeta, E., Shank, K., Wang, S., O'Connor, C., Kunselman, A., Woitas, K., Myers, J. & Undar, A., Feb 1 2018, In : Artificial Organs. 42, 2, p. 155-165 11 p.

Research output: Contribution to journalArticle

Extracorporeal Membrane Oxygenation
Renal Replacement Therapy
Hemodynamics
Networks (circuits)
Electron energy levels
2 Citations (Scopus)

Functional performance of different venous limb options in simulated neonatal/pediatric cardiopulmonary bypass circuits

Caneo, L. F., Matte, G. S., Guimarães, D. P., Viotto, G., Mazzeto, M., Cestari, I., Neirotti, R. A., Jatene, M. B., Wang, S., Undar, A., Chang Junior, J. & Jatene, F. B., May 1 2018, In : Brazilian Journal of Cardiovascular Surgery. 33, 3, p. 224-232 9 p.

Research output: Contribution to journalArticle

Cardiopulmonary Bypass
Extremities
Pediatrics
Oxygenators
Hemodilution
5 Citations (Scopus)

Impact of Different Perfusion Modalities on Coronary and Carotid Blood Flow Velocities in an Adult ECLS Swine Model

Wang, S., Patel, S., Izer, J., Clark, J., Kunselman, A., Wilson, R. & Undar, A., Sep 1 2018, In : Artificial organs. 42, 9, p. 918-921 4 p.

Research output: Contribution to journalArticle

Blood Flow Velocity
Flow velocity
Coronary Vessels
Blood
Swine
3 Citations (Scopus)
Oxygenators
Pediatrics
Hemodynamics
Pulsatile Flow
Pulsatile flow
2 Citations (Scopus)
Centrifugal pumps
Hemodynamics
Networks (circuits)
Pressure
Pumps
5 Citations (Scopus)

In Vitro Evaluation of ECG-Synchronized Pulsatile Flow Using the i-cor Diagonal Pump in Neonatal and Pediatric ECLS Systems

Moroi, M., Force, M., Wang, S., Kunselman, A. & Undar, A., Jul 1 2018, In : Artificial organs. 42, 7, p. E127-E140

Research output: Contribution to journalArticle

Life Support Systems
Pulsatile Flow
Pulsatile flow
Extracorporeal Membrane Oxygenation
Pediatrics
2 Citations (Scopus)

In Vitro Hemodynamic Evaluation of an Adult Pulsatile Extracorporeal Membrane Oxygenation System

Wang, S., Moroi, M., Brehm, C., Kunselman, A. & Undar, A., Sep 1 2018, In : Artificial Organs. 42, 9, p. E234-E245

Research output: Contribution to journalArticle

Extracorporeal Membrane Oxygenation
Oxygenation
Hemodynamics
Membranes
Pulsatile Flow
3 Citations (Scopus)
Pulsatile Flow
Pulsatile flow
Pediatrics
Hemodynamics
Electrocardiography
2017
5 Citations (Scopus)
Oxygenators
Extracorporeal Membrane Oxygenation
Hemodynamics
Pumps
Technology
3 Citations (Scopus)

Does an Open Recirculation Line Affect the Flow Rate and Pressure in a Neonatal Extracorporeal Life Support Circuit With a Centrifugal or Roller Pump?

Wang, S., Spencer, S. B., Woitas, K., Glass, K., Kunselman, A. & Undar, A., Jan 1 2017, In : Artificial organs. 41, 1, p. 70-75 6 p.

Research output: Contribution to journalArticle

Extracorporeal Membrane Oxygenation
Flow rate
Pumps
Pressure
Networks (circuits)
2 Citations (Scopus)

Does Flexible Arterial Tubing Retain More Hemodynamic Energy During Pediatric Pulsatile Extracorporeal Life Support?

Wang, S., Kunselman, A. & Undar, A., Jan 1 2017, In : Artificial organs. 41, 1, p. 47-54 8 p.

Research output: Contribution to journalArticle

Extracorporeal Membrane Oxygenation
Pediatrics
Hemodynamics
Tubing
Latexes

Dr. Yves Durandy, February 20, 1947-October 6, 2016

Undar, A. & Rubatti, M., Jan 1 2017, In : Artificial Organs. 41, 1, p. 5-6 2 p.

Research output: Contribution to journalArticle

Pediatrics
7 Citations (Scopus)

Impact of Translational Research on Optimization of Neonatal Cardiopulmonary Bypass Circuits and Techniques—The Penn State Health Approach

Undar, A., Wang, S., Palanzo, D. A., Wise, R., Woitas, K., Baer, L. D., Kunselman, A., Clark, J. B. & Myers, J., Mar 1 2017, In : Artificial organs. 41, 3, p. 218-223 6 p.

Research output: Contribution to journalArticle

Oxygenators
Health
Networks (circuits)
7 Citations (Scopus)

In Vitro Evaluation of an Alternative Neonatal Extracorporeal Life Support Circuit on Hemodynamic Performance and Bubble Trap

Spencer, S. B., Wang, S., Woitas, K., Glass, K., Kunselman, A. & Undar, A., Jan 1 2017, In : Artificial Organs. 41, 1, p. 17-24 8 p.

Research output: Contribution to journalArticle

Extracorporeal Membrane Oxygenation
Hemodynamics
Urinary Bladder
Networks (circuits)
Centrifugal pumps
4 Citations (Scopus)

In Vitro Evaluation of Pediatric Hollow-Fiber Membrane Oxygenators on Hemodynamic Performance and Gaseous Microemboli Handling: An International Multicenter/Multidisciplinary Approach

Wang, S., Caneo, L. F., Jatene, M. B., Jatene, F. B., Cestari, I. A., Kunselman, A. & Undar, A., Sep 1 2017, In : Artificial Organs. 41, 9, p. 865-874 10 p.

Research output: Contribution to journalArticle

Oxygenators
Membrane Oxygenators
Pediatrics
Hemodynamics
Membranes
6 Citations (Scopus)

Novel ECG-Synchronized Pulsatile ECLS System With Various Heart Rates and Cardiac Arrhythmias: An In Vitro Study

Wang, S., Spencer, S. B., Kunselman, A. & Undar, A., Jan 1 2017, In : Artificial organs. 41, 1, p. 55-65 11 p.

Research output: Contribution to journalArticle

Life Support Systems
Extracorporeal Membrane Oxygenation
Hemodynamics
Electrocardiography
Pulsatile Flow
3 Citations (Scopus)

Ultrasound-guided vessel catheterization in adult Yorkshire cross-bred pigs

Izer, J., Wilson, R., Hernon, K. & Undar, A., Jan 1 2017, In : Veterinary Anaesthesia and Analgesia. 44, 1, p. 133-137 5 p.

Research output: Contribution to journalArticle

Yorkshire (swine breed)
catheters
Catheterization
crossbreds
Swine
2016
3 Citations (Scopus)

Are perioperative near-infrared spectroscopy values correlated with clinical and biochemical parameters in cyanotic and acyanotic infants following corrective cardiac surgery?

Ersoy, C., Özyüksel, A., Alkan Bozkaya, T., Karaaslan, P., Örmeci, T., Undar, A., Akçevin, A. & Türkoʇlu, H., Mar 1 2016, In : Perfusion (United Kingdom). 31, 2, p. 125-130 6 p.

Research output: Contribution to journalArticle

Near infrared spectroscopy
Near-Infrared Spectroscopy
Surgery
surgery
Thoracic Surgery
14 Citations (Scopus)

Effect of the Pulsatile Extracorporeal Membrane Oxygenation on Hemodynamic Energy and Systemic Microcirculation in a Piglet Model of Acute Cardiac Failure

Itoh, H., Ichiba, S., Ujike, Y., Douguchi, T., Obata, H., Inamori, S., Iwasaki, T., Kasahara, S., Sano, S. & Undar, A., Jan 1 2016, In : Artificial organs. 40, 1, p. 19-26 8 p.

Research output: Contribution to journalArticle

Microcirculation
Extracorporeal Membrane Oxygenation
Oxygenation
Hemodynamics
Heart Failure
5 Citations (Scopus)
Oxygenators
Membrane Oxygenators
Cardiopulmonary Bypass
Membranes
Networks (circuits)
4 Citations (Scopus)
Oxygenators
Cardiopulmonary Bypass
Hemodynamics
Embolism
Air
5 Citations (Scopus)

In Vitro Hemodynamic Evaluation of Five 6 Fr and 8 Fr Arterial Cannulae in Simulated Neonatal Cardiopulmonary Bypass Circuits

Wang, S., Palanzo, D., Kunselman, A. & Undar, A., Jan 1 2016, In : Artificial organs. 40, 1, p. 56-64 9 p.

Research output: Contribution to journalArticle

Hemodynamics
Cardiopulmonary Bypass
Tubing
Pressure
Pressure drop
4 Citations (Scopus)

Potential Danger of Pre-Pump Clamping on Negative Pressure-Associated Gaseous Microemboli Generation During Extracorporeal Life Support-An In Vitro Study

Wang, S., Chin, B. J., Gentile, F., Kunselman, A., Palanzo, D. & Undar, A., Jan 1 2016, In : Artificial organs. 40, 1, p. 89-94 6 p.

Research output: Contribution to journalArticle

Extracorporeal Membrane Oxygenation
Oxygenators
Constriction
Pumps
Tubing
9 Citations (Scopus)

The Clinical Importance of Pulsatile Flow in Extracorporeal Life Support: The Penn State Health Approach

Undar, A., Wang, S., Izer, J., Clark, J., Kunselman, A., Patel, S., Shank, K., Profeta, E., Wilson, R. & Ostadal, P., Dec 1 2016, In : Artificial Organs. 40, 12, p. 1101-1104 4 p.

Research output: Contribution to journalArticle

Pulsatile Flow
Pulsatile flow
Extracorporeal Membrane Oxygenation
Left Ventricular Function
Respiratory Insufficiency
2015
6 Citations (Scopus)

Apolipoprotein E levels in pediatric patients undergoing cardiopulmonary bypass

Aĝirbaşli, M., Song, J., Lei, F., Wang, S., Kunselman, A., Clark, J., Myers, J. & Undar, A., Jan 1 2015, In : Artificial Organs. 39, 1, p. 28-33 6 p.

Research output: Contribution to journalArticle

Pediatrics
Apolipoproteins E
Cardiopulmonary Bypass
Clamping devices
Surgery
6 Citations (Scopus)

Computational Modeling of Neonatal Cardiopulmonary Bypass Hemodynamics With Full Circle of Willis Anatomy

Piskin, S., Undar, A. & Pekkan, K., Jan 1 2015, In : Artificial Organs. 39, 10, p. E164-E175

Research output: Contribution to journalArticle

Circle of Willis
Hemodynamics
Arches
Cardiopulmonary Bypass
Anatomy
8 Citations (Scopus)

Correlation between cerebral-renal near-infrared spectroscopy and ipsilateral renal perfusion parameters as clinical outcome predictors after open heart surgery in neonates and infants

Örmeci, T., Alkan-Bozkaya, T., Özyüksel, A., Ersoy, C., Undar, A., Akçevin, A. & Türkoğlu, H., Jan 1 2015, In : Artificial Organs. 39, 1, p. 53-58 6 p.

Research output: Contribution to journalArticle

Near infrared spectroscopy
Near-Infrared Spectroscopy
Surgery
Thoracic Surgery
Ultrasonography
17 Citations (Scopus)
Life Support Systems
Extracorporeal Membrane Oxygenation
Hemodynamics
Pulsatile flow
Pulsatile Flow
13 Citations (Scopus)
Life Support Systems
Extracorporeal Membrane Oxygenation
Pediatrics
Hemodynamics
Oxygenators
9 Citations (Scopus)

Evaluation of different diameter arterial tubing and arterial cannulae in simulated neonatal/pediatric cardiopulmonary bypass circuits

Wang, S., Rosenthal, T., Kunselman, A. & Undar, A., Jan 1 2015, In : Artificial organs. 39, 1, p. 43-52 10 p.

Research output: Contribution to journalArticle

Pediatrics
Tubing
Cardiopulmonary Bypass
Pressure drop
Pressure
17 Citations (Scopus)

Impact of Pulsatility and Flow Rates on Hemodynamic Energy Transmission in an Adult Extracorporeal Life Support System

Wolfe, R., Strother, A., Wang, S., Kunselman, A. & Undar, A., Jul 1 2015, In : Artificial organs. 39, 7, p. E127-E137

Research output: Contribution to journalArticle

Life Support Systems
Extracorporeal Membrane Oxygenation
Hemodynamics
Flow rate
Pulsatile Flow
19 Citations (Scopus)
Life Support Systems
Extracorporeal Membrane Oxygenation
Hemodynamics
Energy dissipation
Pulsatile Flow
21 Citations (Scopus)
Life Support Systems
Extracorporeal Membrane Oxygenation
Hemodynamics
Electrocardiography
Swine
24 Citations (Scopus)

Laboratory Evaluation of Hemolysis and Systemic Inflammatory Response in Neonatal Nonpulsatile and Pulsatile Extracorporeal Life Support Systems

Wang, S., Krawiec, C., Patel, S., Kunselman, A., Song, J., Lei, F., Baer, L. D. & Undar, A., Jan 1 2015, In : Artificial Organs. 39, 9, p. 774-781 8 p.

Research output: Contribution to journalArticle

Life Support Systems
Extracorporeal Membrane Oxygenation
Hemolysis
Pumps
Pulsatile Flow
2014
5 Citations (Scopus)

An original versatile nonocclusive pressure-regulated blood roller pump for extracorporeal perfusion

Durandy, Y., Wang, S. & Undar, A., Jan 1 2014, In : Artificial organs. 38, 6, p. 469-473 5 p.

Research output: Contribution to journalArticle

Infusion Pumps
Blood pressure
Pumps
Blood Pressure
Lung
14 Citations (Scopus)

Comparative Effects of Pulsatile and Nonpulsatile Flow on Plasma Fibrinolytic Balance in Pediatric Patients Undergoing Cardiopulmonary Bypass

Aĝirbaşli, M. A., Song, J., Lei, F., Wang, S., Kunselman, A., Clark, J., Myers, J. & Undar, A., Jan 1 2014, In : Artificial Organs. 38, 1, p. 28-33 6 p.

Research output: Contribution to journalArticle

Pulsatile Flow
Pediatrics
Plasminogen Activator Inhibitor 1
Tissue Plasminogen Activator
Cardiopulmonary Bypass
15 Citations (Scopus)
Life Support Systems
Pulsatile Flow
Pulsatile flow
Extracorporeal Membrane Oxygenation
Pediatrics
10 Citations (Scopus)
Life Support Systems
Pulsatile Flow
Extracorporeal Membrane Oxygenation
Hemodynamics
Pediatrics
4 Citations (Scopus)
Hemodynamics
Cardiopulmonary Bypass
Pumps
Oxygenators
Pediatrics
8 Citations (Scopus)
Pediatrics
Cardiovascular System
Pumps
Hemodynamics
Pulsatile Flow