A DANTE tagging sequence for the evaluation of translational sample motion

Timothy J. Mosher, Michael B. Smith

Research output: Contribution to journalArticle

146 Citations (Scopus)

Abstract

A magnetic resonance imaging sequence that is sensitive to translational motion such as that seen with cardiac contraction is presented. The sequence employs DANTE radiofrequency excitation with a continuous magnetic field gradient to generate a grid pattern of lines. There is improved line resolution and reduced eddy‐current formation over Current techniques. © 1990 Academic Press, Inc.

Original languageEnglish (US)
Pages (from-to)334-339
Number of pages6
JournalMagnetic Resonance in Medicine
Volume15
Issue number2
DOIs
StatePublished - Aug 1990

Fingerprint

Magnetic Fields
Magnetic Resonance Imaging

All Science Journal Classification (ASJC) codes

  • Radiology Nuclear Medicine and imaging

Cite this

@article{84339122312945fba7154de648092746,
title = "A DANTE tagging sequence for the evaluation of translational sample motion",
abstract = "A magnetic resonance imaging sequence that is sensitive to translational motion such as that seen with cardiac contraction is presented. The sequence employs DANTE radiofrequency excitation with a continuous magnetic field gradient to generate a grid pattern of lines. There is improved line resolution and reduced eddy‐current formation over Current techniques. {\circledC} 1990 Academic Press, Inc.",
author = "Mosher, {Timothy J.} and Smith, {Michael B.}",
year = "1990",
month = "8",
doi = "10.1002/mrm.1910150215",
language = "English (US)",
volume = "15",
pages = "334--339",
journal = "Magnetic Resonance in Medicine",
issn = "0740-3194",
publisher = "John Wiley and Sons Inc.",
number = "2",

}

A DANTE tagging sequence for the evaluation of translational sample motion. / Mosher, Timothy J.; Smith, Michael B.

In: Magnetic Resonance in Medicine, Vol. 15, No. 2, 08.1990, p. 334-339.

Research output: Contribution to journalArticle

TY - JOUR

T1 - A DANTE tagging sequence for the evaluation of translational sample motion

AU - Mosher, Timothy J.

AU - Smith, Michael B.

PY - 1990/8

Y1 - 1990/8

N2 - A magnetic resonance imaging sequence that is sensitive to translational motion such as that seen with cardiac contraction is presented. The sequence employs DANTE radiofrequency excitation with a continuous magnetic field gradient to generate a grid pattern of lines. There is improved line resolution and reduced eddy‐current formation over Current techniques. © 1990 Academic Press, Inc.

AB - A magnetic resonance imaging sequence that is sensitive to translational motion such as that seen with cardiac contraction is presented. The sequence employs DANTE radiofrequency excitation with a continuous magnetic field gradient to generate a grid pattern of lines. There is improved line resolution and reduced eddy‐current formation over Current techniques. © 1990 Academic Press, Inc.

UR - http://www.scopus.com/inward/record.url?scp=0024987905&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0024987905&partnerID=8YFLogxK

U2 - 10.1002/mrm.1910150215

DO - 10.1002/mrm.1910150215

M3 - Article

C2 - 2392056

AN - SCOPUS:0024987905

VL - 15

SP - 334

EP - 339

JO - Magnetic Resonance in Medicine

JF - Magnetic Resonance in Medicine

SN - 0740-3194

IS - 2

ER -