A novel over-the-scope deployment method for enteral stent placement

Eric Pauli, Steve J. Schomisch, Jeffrey A. Blatnik, David M. Krpata, Juan S. Sanabria, Jeffrey M. Marks

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

Background: Over the last two decades, self-expanding enteral stents have gained popularity and shown therapeutic potential for strictures, obstructions, fistulae, and perforations of the gastrointestinal (GI) tract. Currently available stent delivery systems make deployment in many locations in the GI tract difficult due to the inability to traverse curves or impossible due to the size requirements of the deployment systems. Methods: A 67-year-old male presented to our hospital with severe gallstone pancreatitis, requiring a prolonged intensive care unit course. Two days after discharge to a rehabilitation facility he developed acute abdominal pain and pneumoperitoneum. Operative exploration failed to identify a perforation. Subsequently, a left-upper-quadrant abscess developed that was drained percutaneously, yielding coliform bacteria. The drain produced several hundred milliliters of stool a day. A barium enema demonstrated a perforation in the descending colon from an old colo-colic anastomosis site. We proposed a novel over-the-scope (OTS) stent deployment method. Utilizing a heat-activated polymer sheath, the stent was affixed to the endoscope. A modified speed-banding attachment was created to permit release of the polymer sheath once endoscopic and fluoroscopic confirmation of the correct position was obtained. Results: Utilizing this method of OTS stent deployment, a fully covered 23 × 155 mm self-expanding metal stent (WallFlex, Boston Scientific, Natick, MA) was placed in the colon. Endoscopic and fluoroscopic evaluation following stent placement confirmed stent coverage of the perforation with no ongoing evidence of leak. The patient was discharged to his home state 2 weeks after stent placement in stable condition. Conclusion: We have developed a novel method of OTS stent placement that permits deployment of a variety of enteral stents on any available endoscope. This method permits placement of fully covered stents in locations in the GI tract not reachable with currently available delivery systems.

Original languageEnglish (US)
Pages (from-to)1410-1411
Number of pages2
JournalSurgical Endoscopy
Volume27
Issue number4
DOIs
StatePublished - Jan 1 2013

Fingerprint

Small Intestine
Stents
Gastrointestinal Tract
Endoscopes
Polymers
Descending Colon
Pneumoperitoneum
Colic
Acute Pain
Gallstones
Pancreatitis
Abscess
Abdominal Pain
Fistula
Intensive Care Units
Pathologic Constriction
Colon
Rehabilitation
Hot Temperature
Metals

All Science Journal Classification (ASJC) codes

  • Surgery

Cite this

Pauli, E., Schomisch, S. J., Blatnik, J. A., Krpata, D. M., Sanabria, J. S., & Marks, J. M. (2013). A novel over-the-scope deployment method for enteral stent placement. Surgical Endoscopy, 27(4), 1410-1411. https://doi.org/10.1007/s00464-012-2564-1
Pauli, Eric ; Schomisch, Steve J. ; Blatnik, Jeffrey A. ; Krpata, David M. ; Sanabria, Juan S. ; Marks, Jeffrey M. / A novel over-the-scope deployment method for enteral stent placement. In: Surgical Endoscopy. 2013 ; Vol. 27, No. 4. pp. 1410-1411.
@article{8135b1c52d4543b49a2853bfc0120d23,
title = "A novel over-the-scope deployment method for enteral stent placement",
abstract = "Background: Over the last two decades, self-expanding enteral stents have gained popularity and shown therapeutic potential for strictures, obstructions, fistulae, and perforations of the gastrointestinal (GI) tract. Currently available stent delivery systems make deployment in many locations in the GI tract difficult due to the inability to traverse curves or impossible due to the size requirements of the deployment systems. Methods: A 67-year-old male presented to our hospital with severe gallstone pancreatitis, requiring a prolonged intensive care unit course. Two days after discharge to a rehabilitation facility he developed acute abdominal pain and pneumoperitoneum. Operative exploration failed to identify a perforation. Subsequently, a left-upper-quadrant abscess developed that was drained percutaneously, yielding coliform bacteria. The drain produced several hundred milliliters of stool a day. A barium enema demonstrated a perforation in the descending colon from an old colo-colic anastomosis site. We proposed a novel over-the-scope (OTS) stent deployment method. Utilizing a heat-activated polymer sheath, the stent was affixed to the endoscope. A modified speed-banding attachment was created to permit release of the polymer sheath once endoscopic and fluoroscopic confirmation of the correct position was obtained. Results: Utilizing this method of OTS stent deployment, a fully covered 23 × 155 mm self-expanding metal stent (WallFlex, Boston Scientific, Natick, MA) was placed in the colon. Endoscopic and fluoroscopic evaluation following stent placement confirmed stent coverage of the perforation with no ongoing evidence of leak. The patient was discharged to his home state 2 weeks after stent placement in stable condition. Conclusion: We have developed a novel method of OTS stent placement that permits deployment of a variety of enteral stents on any available endoscope. This method permits placement of fully covered stents in locations in the GI tract not reachable with currently available delivery systems.",
author = "Eric Pauli and Schomisch, {Steve J.} and Blatnik, {Jeffrey A.} and Krpata, {David M.} and Sanabria, {Juan S.} and Marks, {Jeffrey M.}",
year = "2013",
month = "1",
day = "1",
doi = "10.1007/s00464-012-2564-1",
language = "English (US)",
volume = "27",
pages = "1410--1411",
journal = "Surgical Endoscopy",
issn = "0930-2794",
publisher = "Springer New York",
number = "4",

}

Pauli, E, Schomisch, SJ, Blatnik, JA, Krpata, DM, Sanabria, JS & Marks, JM 2013, 'A novel over-the-scope deployment method for enteral stent placement', Surgical Endoscopy, vol. 27, no. 4, pp. 1410-1411. https://doi.org/10.1007/s00464-012-2564-1

A novel over-the-scope deployment method for enteral stent placement. / Pauli, Eric; Schomisch, Steve J.; Blatnik, Jeffrey A.; Krpata, David M.; Sanabria, Juan S.; Marks, Jeffrey M.

In: Surgical Endoscopy, Vol. 27, No. 4, 01.01.2013, p. 1410-1411.

Research output: Contribution to journalArticle

TY - JOUR

T1 - A novel over-the-scope deployment method for enteral stent placement

AU - Pauli, Eric

AU - Schomisch, Steve J.

AU - Blatnik, Jeffrey A.

AU - Krpata, David M.

AU - Sanabria, Juan S.

AU - Marks, Jeffrey M.

PY - 2013/1/1

Y1 - 2013/1/1

N2 - Background: Over the last two decades, self-expanding enteral stents have gained popularity and shown therapeutic potential for strictures, obstructions, fistulae, and perforations of the gastrointestinal (GI) tract. Currently available stent delivery systems make deployment in many locations in the GI tract difficult due to the inability to traverse curves or impossible due to the size requirements of the deployment systems. Methods: A 67-year-old male presented to our hospital with severe gallstone pancreatitis, requiring a prolonged intensive care unit course. Two days after discharge to a rehabilitation facility he developed acute abdominal pain and pneumoperitoneum. Operative exploration failed to identify a perforation. Subsequently, a left-upper-quadrant abscess developed that was drained percutaneously, yielding coliform bacteria. The drain produced several hundred milliliters of stool a day. A barium enema demonstrated a perforation in the descending colon from an old colo-colic anastomosis site. We proposed a novel over-the-scope (OTS) stent deployment method. Utilizing a heat-activated polymer sheath, the stent was affixed to the endoscope. A modified speed-banding attachment was created to permit release of the polymer sheath once endoscopic and fluoroscopic confirmation of the correct position was obtained. Results: Utilizing this method of OTS stent deployment, a fully covered 23 × 155 mm self-expanding metal stent (WallFlex, Boston Scientific, Natick, MA) was placed in the colon. Endoscopic and fluoroscopic evaluation following stent placement confirmed stent coverage of the perforation with no ongoing evidence of leak. The patient was discharged to his home state 2 weeks after stent placement in stable condition. Conclusion: We have developed a novel method of OTS stent placement that permits deployment of a variety of enteral stents on any available endoscope. This method permits placement of fully covered stents in locations in the GI tract not reachable with currently available delivery systems.

AB - Background: Over the last two decades, self-expanding enteral stents have gained popularity and shown therapeutic potential for strictures, obstructions, fistulae, and perforations of the gastrointestinal (GI) tract. Currently available stent delivery systems make deployment in many locations in the GI tract difficult due to the inability to traverse curves or impossible due to the size requirements of the deployment systems. Methods: A 67-year-old male presented to our hospital with severe gallstone pancreatitis, requiring a prolonged intensive care unit course. Two days after discharge to a rehabilitation facility he developed acute abdominal pain and pneumoperitoneum. Operative exploration failed to identify a perforation. Subsequently, a left-upper-quadrant abscess developed that was drained percutaneously, yielding coliform bacteria. The drain produced several hundred milliliters of stool a day. A barium enema demonstrated a perforation in the descending colon from an old colo-colic anastomosis site. We proposed a novel over-the-scope (OTS) stent deployment method. Utilizing a heat-activated polymer sheath, the stent was affixed to the endoscope. A modified speed-banding attachment was created to permit release of the polymer sheath once endoscopic and fluoroscopic confirmation of the correct position was obtained. Results: Utilizing this method of OTS stent deployment, a fully covered 23 × 155 mm self-expanding metal stent (WallFlex, Boston Scientific, Natick, MA) was placed in the colon. Endoscopic and fluoroscopic evaluation following stent placement confirmed stent coverage of the perforation with no ongoing evidence of leak. The patient was discharged to his home state 2 weeks after stent placement in stable condition. Conclusion: We have developed a novel method of OTS stent placement that permits deployment of a variety of enteral stents on any available endoscope. This method permits placement of fully covered stents in locations in the GI tract not reachable with currently available delivery systems.

UR - http://www.scopus.com/inward/record.url?scp=84876296279&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84876296279&partnerID=8YFLogxK

U2 - 10.1007/s00464-012-2564-1

DO - 10.1007/s00464-012-2564-1

M3 - Article

C2 - 23052538

AN - SCOPUS:84876296279

VL - 27

SP - 1410

EP - 1411

JO - Surgical Endoscopy

JF - Surgical Endoscopy

SN - 0930-2794

IS - 4

ER -

Pauli E, Schomisch SJ, Blatnik JA, Krpata DM, Sanabria JS, Marks JM. A novel over-the-scope deployment method for enteral stent placement. Surgical Endoscopy. 2013 Jan 1;27(4):1410-1411. https://doi.org/10.1007/s00464-012-2564-1