    This paper describes a general technique for fitting a spatial kinematic model to an in-vivo anatomical joint under typical physiological loading conditions. The method employs a nonlinear least squares algorithm to minimize the aggregate deviation between postulated model motion and experimentally measured anatomical joint motion over multiple joint positions. Estimation of the parameters of a universal joint with skew-oblique revolutes to best reproduce wrist motion was used as an example. Experimental motion data from the right wrists of five subjects were analyzed. The technique performed very well and produced repeatable results consistent with previous biomechanical wrist findings.

    Original languageEnglish (US)
    Pages (from-to)311-317
    Number of pages7
    JournalJournal of Biomechanical Engineering
    Volume102
    Issue number4
    DOIs
    StatePublished - Jan 1 1980

    Fingerprint

    Biomechanical Phenomena
    Kinematics
    Joints
    Wrist
    Universal joints
    Least-Squares Analysis

    All Science Journal Classification (ASJC) codes

    • Biomedical Engineering
    • Physiology (medical)

    Cite this

    @article{c47d4a1e0a544fce96b290f48cd310a8,
    title = "A technique for kinematic modeling of anatomical joints",
    abstract = "This paper describes a general technique for fitting a spatial kinematic model to an in-vivo anatomical joint under typical physiological loading conditions. The method employs a nonlinear least squares algorithm to minimize the aggregate deviation between postulated model motion and experimentally measured anatomical joint motion over multiple joint positions. Estimation of the parameters of a universal joint with skew-oblique revolutes to best reproduce wrist motion was used as an example. Experimental motion data from the right wrists of five subjects were analyzed. The technique performed very well and produced repeatable results consistent with previous biomechanical wrist findings.",
    author = "{Sommer, III}, {Henry Joseph} and Miller, {N. R.}",
    year = "1980",
    month = "1",
    day = "1",
    doi = "10.1115/1.3138228",
    language = "English (US)",
    volume = "102",
    pages = "311--317",
    journal = "Journal of Biomechanical Engineering",
    issn = "0148-0731",
    publisher = "American Society of Mechanical Engineers(ASME)",
    number = "4",

    }

    A technique for kinematic modeling of anatomical joints. / Sommer, III, Henry Joseph; Miller, N. R.

    In: Journal of Biomechanical Engineering, Vol. 102, No. 4, 01.01.1980, p. 311-317.

    Research output: Contribution to journalArticle

    TY - JOUR

    T1 - A technique for kinematic modeling of anatomical joints

    AU - Sommer, III, Henry Joseph

    AU - Miller, N. R.

    PY - 1980/1/1

    Y1 - 1980/1/1

    N2 - This paper describes a general technique for fitting a spatial kinematic model to an in-vivo anatomical joint under typical physiological loading conditions. The method employs a nonlinear least squares algorithm to minimize the aggregate deviation between postulated model motion and experimentally measured anatomical joint motion over multiple joint positions. Estimation of the parameters of a universal joint with skew-oblique revolutes to best reproduce wrist motion was used as an example. Experimental motion data from the right wrists of five subjects were analyzed. The technique performed very well and produced repeatable results consistent with previous biomechanical wrist findings.

    AB - This paper describes a general technique for fitting a spatial kinematic model to an in-vivo anatomical joint under typical physiological loading conditions. The method employs a nonlinear least squares algorithm to minimize the aggregate deviation between postulated model motion and experimentally measured anatomical joint motion over multiple joint positions. Estimation of the parameters of a universal joint with skew-oblique revolutes to best reproduce wrist motion was used as an example. Experimental motion data from the right wrists of five subjects were analyzed. The technique performed very well and produced repeatable results consistent with previous biomechanical wrist findings.

    UR - http://www.scopus.com/inward/record.url?scp=0019083629&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=0019083629&partnerID=8YFLogxK

    U2 - 10.1115/1.3138228

    DO - 10.1115/1.3138228

    M3 - Article

    C2 - 6965194

    AN - SCOPUS:0019083629

    VL - 102

    SP - 311

    EP - 317

    JO - Journal of Biomechanical Engineering

    JF - Journal of Biomechanical Engineering

    SN - 0148-0731

    IS - 4

    ER -