Actuator fault detection and isolation in nonlinear systems using LMI's and LME's

Edwin Engin Yaz, Asad Azemi

Research output: Chapter in Book/Report/Conference proceedingConference contribution

28 Scopus citations

Abstract

An actuator fault detection and isolation scheme for a class of continuous-time nonlinear systems is presented. A bank of unknown-input observers is used for this purpose. Only linear matrix equations and inequalities are used in the design which makes it particularly attractive from a computational viewpoint.

Original languageEnglish (US)
Title of host publicationProceedings of the 1998 American Control Conference, ACC 1998
Pages1590-1594
Number of pages5
DOIs
StatePublished - Dec 1 1998
Event1998 American Control Conference, ACC 1998 - Philadelphia, PA, United States
Duration: Jun 24 1998Jun 26 1998

Publication series

NameProceedings of the American Control Conference
Volume3
ISSN (Print)0743-1619

Other

Other1998 American Control Conference, ACC 1998
CountryUnited States
CityPhiladelphia, PA
Period6/24/986/26/98

    Fingerprint

All Science Journal Classification (ASJC) codes

  • Electrical and Electronic Engineering

Cite this

Yaz, E. E., & Azemi, A. (1998). Actuator fault detection and isolation in nonlinear systems using LMI's and LME's. In Proceedings of the 1998 American Control Conference, ACC 1998 (pp. 1590-1594). [707274] (Proceedings of the American Control Conference; Vol. 3). https://doi.org/10.1109/ACC.1998.707274