Advances in the accuracy, stability, and reliability of the PTB primary fountain clocks

S. Weyers, V. Gerginov, M. Kazda, J. Rahm, B. Lipphardt, G. Dobrev, K. Gibble

Research output: Contribution to journalArticle

9 Citations (Scopus)

Abstract

Improvements of the systematic uncertainty, frequency instability, and long-term reliability of the two caesium fountain primary frequency standards CSF1 and CSF2 at PTB (Physikalisch-Technische Bundesanstalt) are described. We have further investigated many of the systematic effects and made a number of modifications of the fountains. With an optically stabilized microwave oscillator, the quantum projection noise limited frequency instabilities are improved to 7.2 × 10-14(τ/1 s)-1/2 for CSF1 and 2.5 × 10-14(τ/1 s)-1/2 for CSF2 at high atom density. The systematic uncertainties of CSF1 and CSF2 are reduced to 2.74 × 10-16 and 1.71 × 10-16, respectively. Both fountain clocks regularly calibrate the scale unit of International Atomic Time (TAI) and the local realization of Coordinated Universal Time, UTC(PTB), and serve as references to measure the frequencies of local and remote optical frequency standards.

Original languageEnglish (US)
Article number789
JournalMetrologia
Volume55
Issue number6
DOIs
StatePublished - Oct 19 2018

Fingerprint

Fountains
Clocks
Frequency standards
Microwave oscillators
Cesium
Atoms
Uncertainty

All Science Journal Classification (ASJC) codes

  • Engineering(all)

Cite this

Weyers, S. ; Gerginov, V. ; Kazda, M. ; Rahm, J. ; Lipphardt, B. ; Dobrev, G. ; Gibble, K. / Advances in the accuracy, stability, and reliability of the PTB primary fountain clocks. In: Metrologia. 2018 ; Vol. 55, No. 6.
@article{0401e210472f4241a4ea4e84dd60807a,
title = "Advances in the accuracy, stability, and reliability of the PTB primary fountain clocks",
abstract = "Improvements of the systematic uncertainty, frequency instability, and long-term reliability of the two caesium fountain primary frequency standards CSF1 and CSF2 at PTB (Physikalisch-Technische Bundesanstalt) are described. We have further investigated many of the systematic effects and made a number of modifications of the fountains. With an optically stabilized microwave oscillator, the quantum projection noise limited frequency instabilities are improved to 7.2 × 10-14(τ/1 s)-1/2 for CSF1 and 2.5 × 10-14(τ/1 s)-1/2 for CSF2 at high atom density. The systematic uncertainties of CSF1 and CSF2 are reduced to 2.74 × 10-16 and 1.71 × 10-16, respectively. Both fountain clocks regularly calibrate the scale unit of International Atomic Time (TAI) and the local realization of Coordinated Universal Time, UTC(PTB), and serve as references to measure the frequencies of local and remote optical frequency standards.",
author = "S. Weyers and V. Gerginov and M. Kazda and J. Rahm and B. Lipphardt and G. Dobrev and K. Gibble",
year = "2018",
month = "10",
day = "19",
doi = "10.1088/1681-7575/aae008",
language = "English (US)",
volume = "55",
journal = "Metrologia",
issn = "0026-1394",
publisher = "IOP Publishing Ltd.",
number = "6",

}

Weyers, S, Gerginov, V, Kazda, M, Rahm, J, Lipphardt, B, Dobrev, G & Gibble, K 2018, 'Advances in the accuracy, stability, and reliability of the PTB primary fountain clocks', Metrologia, vol. 55, no. 6, 789. https://doi.org/10.1088/1681-7575/aae008

Advances in the accuracy, stability, and reliability of the PTB primary fountain clocks. / Weyers, S.; Gerginov, V.; Kazda, M.; Rahm, J.; Lipphardt, B.; Dobrev, G.; Gibble, K.

In: Metrologia, Vol. 55, No. 6, 789, 19.10.2018.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Advances in the accuracy, stability, and reliability of the PTB primary fountain clocks

AU - Weyers, S.

AU - Gerginov, V.

AU - Kazda, M.

AU - Rahm, J.

AU - Lipphardt, B.

AU - Dobrev, G.

AU - Gibble, K.

PY - 2018/10/19

Y1 - 2018/10/19

N2 - Improvements of the systematic uncertainty, frequency instability, and long-term reliability of the two caesium fountain primary frequency standards CSF1 and CSF2 at PTB (Physikalisch-Technische Bundesanstalt) are described. We have further investigated many of the systematic effects and made a number of modifications of the fountains. With an optically stabilized microwave oscillator, the quantum projection noise limited frequency instabilities are improved to 7.2 × 10-14(τ/1 s)-1/2 for CSF1 and 2.5 × 10-14(τ/1 s)-1/2 for CSF2 at high atom density. The systematic uncertainties of CSF1 and CSF2 are reduced to 2.74 × 10-16 and 1.71 × 10-16, respectively. Both fountain clocks regularly calibrate the scale unit of International Atomic Time (TAI) and the local realization of Coordinated Universal Time, UTC(PTB), and serve as references to measure the frequencies of local and remote optical frequency standards.

AB - Improvements of the systematic uncertainty, frequency instability, and long-term reliability of the two caesium fountain primary frequency standards CSF1 and CSF2 at PTB (Physikalisch-Technische Bundesanstalt) are described. We have further investigated many of the systematic effects and made a number of modifications of the fountains. With an optically stabilized microwave oscillator, the quantum projection noise limited frequency instabilities are improved to 7.2 × 10-14(τ/1 s)-1/2 for CSF1 and 2.5 × 10-14(τ/1 s)-1/2 for CSF2 at high atom density. The systematic uncertainties of CSF1 and CSF2 are reduced to 2.74 × 10-16 and 1.71 × 10-16, respectively. Both fountain clocks regularly calibrate the scale unit of International Atomic Time (TAI) and the local realization of Coordinated Universal Time, UTC(PTB), and serve as references to measure the frequencies of local and remote optical frequency standards.

UR - http://www.scopus.com/inward/record.url?scp=85056750162&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85056750162&partnerID=8YFLogxK

U2 - 10.1088/1681-7575/aae008

DO - 10.1088/1681-7575/aae008

M3 - Article

AN - SCOPUS:85056750162

VL - 55

JO - Metrologia

JF - Metrologia

SN - 0026-1394

IS - 6

M1 - 789

ER -