An apparatus to measure flexor tendon excursion and angular motion of the distal interphalangeal joint in a rabbit model

Edward W. Younger, Neil Sharkey, Robert M. Szabo

Research output: Contribution to journalArticle

7 Citations (Scopus)

Abstract

Investigators evaluating flexor tendon adhesions have utilized visual, histological, and gross mechanical methods in reporting their results. We have developed a device to measure tendon excursion and distal interphalangeal joint motion for a small animal model. The device was tested for accuracy and reproducibility using the rabbit hindfoot. There was no statistical difference between the right and the left in 30 paris of feet. This device provides an accurate method to quantify tendon excursion and relative adhesion formation in a rabbit model without destroying the specimen.

Original languageEnglish (US)
Pages (from-to)462-464
Number of pages3
JournalJournal of Orthopaedic Research
Volume6
Issue number3
DOIs
StatePublished - Jan 1 1988

Fingerprint

Tendons
Joints
Rabbits
Equipment and Supplies
Paris
Foot
Animal Models
Research Personnel

All Science Journal Classification (ASJC) codes

  • Orthopedics and Sports Medicine

Cite this

@article{443fcc06a7b64666a199764197098266,
title = "An apparatus to measure flexor tendon excursion and angular motion of the distal interphalangeal joint in a rabbit model",
abstract = "Investigators evaluating flexor tendon adhesions have utilized visual, histological, and gross mechanical methods in reporting their results. We have developed a device to measure tendon excursion and distal interphalangeal joint motion for a small animal model. The device was tested for accuracy and reproducibility using the rabbit hindfoot. There was no statistical difference between the right and the left in 30 paris of feet. This device provides an accurate method to quantify tendon excursion and relative adhesion formation in a rabbit model without destroying the specimen.",
author = "Younger, {Edward W.} and Neil Sharkey and Szabo, {Robert M.}",
year = "1988",
month = "1",
day = "1",
doi = "10.1002/jor.1100060318",
language = "English (US)",
volume = "6",
pages = "462--464",
journal = "Journal of Orthopaedic Research",
issn = "0736-0266",
publisher = "John Wiley and Sons Inc.",
number = "3",

}

An apparatus to measure flexor tendon excursion and angular motion of the distal interphalangeal joint in a rabbit model. / Younger, Edward W.; Sharkey, Neil; Szabo, Robert M.

In: Journal of Orthopaedic Research, Vol. 6, No. 3, 01.01.1988, p. 462-464.

Research output: Contribution to journalArticle

TY - JOUR

T1 - An apparatus to measure flexor tendon excursion and angular motion of the distal interphalangeal joint in a rabbit model

AU - Younger, Edward W.

AU - Sharkey, Neil

AU - Szabo, Robert M.

PY - 1988/1/1

Y1 - 1988/1/1

N2 - Investigators evaluating flexor tendon adhesions have utilized visual, histological, and gross mechanical methods in reporting their results. We have developed a device to measure tendon excursion and distal interphalangeal joint motion for a small animal model. The device was tested for accuracy and reproducibility using the rabbit hindfoot. There was no statistical difference between the right and the left in 30 paris of feet. This device provides an accurate method to quantify tendon excursion and relative adhesion formation in a rabbit model without destroying the specimen.

AB - Investigators evaluating flexor tendon adhesions have utilized visual, histological, and gross mechanical methods in reporting their results. We have developed a device to measure tendon excursion and distal interphalangeal joint motion for a small animal model. The device was tested for accuracy and reproducibility using the rabbit hindfoot. There was no statistical difference between the right and the left in 30 paris of feet. This device provides an accurate method to quantify tendon excursion and relative adhesion formation in a rabbit model without destroying the specimen.

UR - http://www.scopus.com/inward/record.url?scp=0023897591&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0023897591&partnerID=8YFLogxK

U2 - 10.1002/jor.1100060318

DO - 10.1002/jor.1100060318

M3 - Article

C2 - 3357094

AN - SCOPUS:0023897591

VL - 6

SP - 462

EP - 464

JO - Journal of Orthopaedic Research

JF - Journal of Orthopaedic Research

SN - 0736-0266

IS - 3

ER -