Analysis of bioglass fixation of hip prostheses

L. L. Hench, Carlo G. Pantano, P. J. Buscemi, D. C. Greenspan

Research output: Contribution to journalArticle

54 Citations (Scopus)

Abstract

The analysis of the bonding interface between hip prostheses and bone after functional use in animals was carried out. Scanning electron microscopy (SEM) with energy dispersive analysis (EDX), and Auger electron spectroscopy were used to evaluate the bonding interface. Various methods of postsacrifice sample preparation were used to evaluate the effect of such different methods on the analysis of the bonding interface. Comparison of the results with several rat tibia implant experiments is also presented.

Original languageEnglish (US)
Pages (from-to)267-282
Number of pages16
JournalJournal of Biomedical Materials Research
Volume11
Issue number2
DOIs
StatePublished - Jan 1 1977

Fingerprint

Hip prostheses
Bioactive glass
Auger electron spectroscopy
Rats
Energy dispersive spectroscopy
Bone
Animals
Scanning electron microscopy
Bioglass
Experiments

All Science Journal Classification (ASJC) codes

  • Biomaterials
  • Biomedical Engineering

Cite this

Hench, L. L., Pantano, C. G., Buscemi, P. J., & Greenspan, D. C. (1977). Analysis of bioglass fixation of hip prostheses. Journal of Biomedical Materials Research, 11(2), 267-282. https://doi.org/10.1002/jbm.820110211
Hench, L. L. ; Pantano, Carlo G. ; Buscemi, P. J. ; Greenspan, D. C. / Analysis of bioglass fixation of hip prostheses. In: Journal of Biomedical Materials Research. 1977 ; Vol. 11, No. 2. pp. 267-282.
@article{b299338c84e943ba96dd7f33d5e9f6df,
title = "Analysis of bioglass fixation of hip prostheses",
abstract = "The analysis of the bonding interface between hip prostheses and bone after functional use in animals was carried out. Scanning electron microscopy (SEM) with energy dispersive analysis (EDX), and Auger electron spectroscopy were used to evaluate the bonding interface. Various methods of postsacrifice sample preparation were used to evaluate the effect of such different methods on the analysis of the bonding interface. Comparison of the results with several rat tibia implant experiments is also presented.",
author = "Hench, {L. L.} and Pantano, {Carlo G.} and Buscemi, {P. J.} and Greenspan, {D. C.}",
year = "1977",
month = "1",
day = "1",
doi = "10.1002/jbm.820110211",
language = "English (US)",
volume = "11",
pages = "267--282",
journal = "Journal of Biomedical Materials Research",
issn = "0021-9304",
publisher = "Heterocorporation",
number = "2",

}

Hench, LL, Pantano, CG, Buscemi, PJ & Greenspan, DC 1977, 'Analysis of bioglass fixation of hip prostheses', Journal of Biomedical Materials Research, vol. 11, no. 2, pp. 267-282. https://doi.org/10.1002/jbm.820110211

Analysis of bioglass fixation of hip prostheses. / Hench, L. L.; Pantano, Carlo G.; Buscemi, P. J.; Greenspan, D. C.

In: Journal of Biomedical Materials Research, Vol. 11, No. 2, 01.01.1977, p. 267-282.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Analysis of bioglass fixation of hip prostheses

AU - Hench, L. L.

AU - Pantano, Carlo G.

AU - Buscemi, P. J.

AU - Greenspan, D. C.

PY - 1977/1/1

Y1 - 1977/1/1

N2 - The analysis of the bonding interface between hip prostheses and bone after functional use in animals was carried out. Scanning electron microscopy (SEM) with energy dispersive analysis (EDX), and Auger electron spectroscopy were used to evaluate the bonding interface. Various methods of postsacrifice sample preparation were used to evaluate the effect of such different methods on the analysis of the bonding interface. Comparison of the results with several rat tibia implant experiments is also presented.

AB - The analysis of the bonding interface between hip prostheses and bone after functional use in animals was carried out. Scanning electron microscopy (SEM) with energy dispersive analysis (EDX), and Auger electron spectroscopy were used to evaluate the bonding interface. Various methods of postsacrifice sample preparation were used to evaluate the effect of such different methods on the analysis of the bonding interface. Comparison of the results with several rat tibia implant experiments is also presented.

UR - http://www.scopus.com/inward/record.url?scp=0017462005&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0017462005&partnerID=8YFLogxK

U2 - 10.1002/jbm.820110211

DO - 10.1002/jbm.820110211

M3 - Article

C2 - 404298

AN - SCOPUS:0017462005

VL - 11

SP - 267

EP - 282

JO - Journal of Biomedical Materials Research

JF - Journal of Biomedical Materials Research

SN - 0021-9304

IS - 2

ER -