Abstract

Recent statistical work is applied to measuring imbalance in a single plane, often referred to as static imbalance, for a rigid rotor. The two-dimensional repeatability and reproducibility of imbalance measurement are estimated by circles constructed from MANOVA-based method-of-moments and the results are compared to those of one-dimensional repeatability and reproducibility using the same measurement data. The results of both the one-dimensional and the two-dimensional repeatability and reproducibility are interpreted in terms of capability or how the measurement variation relates to rotor imbalance specification or tolerance.

Original languageEnglish (US)
Pages (from-to)29-37
Number of pages9
JournalQuality Engineering
Volume19
Issue number1
DOIs
StatePublished - Jan 1 2007

Fingerprint

Gages
Rigid rotors
Method of moments
Rotors
Specifications

All Science Journal Classification (ASJC) codes

  • Safety, Risk, Reliability and Quality
  • Industrial and Manufacturing Engineering

Cite this

@article{6f41e1a17b5b443589541b4e7ceae3b3,
title = "Analysis of two-dimensional gage repeatability and reproducibility",
abstract = "Recent statistical work is applied to measuring imbalance in a single plane, often referred to as static imbalance, for a rigid rotor. The two-dimensional repeatability and reproducibility of imbalance measurement are estimated by circles constructed from MANOVA-based method-of-moments and the results are compared to those of one-dimensional repeatability and reproducibility using the same measurement data. The results of both the one-dimensional and the two-dimensional repeatability and reproducibility are interpreted in terms of capability or how the measurement variation relates to rotor imbalance specification or tolerance.",
author = "Shannon Sweeney",
year = "2007",
month = "1",
day = "1",
doi = "10.1080/08982110601057641",
language = "English (US)",
volume = "19",
pages = "29--37",
journal = "Quality Engineering",
issn = "0898-2112",
publisher = "Taylor and Francis Ltd.",
number = "1",

}

Analysis of two-dimensional gage repeatability and reproducibility. / Sweeney, Shannon.

In: Quality Engineering, Vol. 19, No. 1, 01.01.2007, p. 29-37.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Analysis of two-dimensional gage repeatability and reproducibility

AU - Sweeney, Shannon

PY - 2007/1/1

Y1 - 2007/1/1

N2 - Recent statistical work is applied to measuring imbalance in a single plane, often referred to as static imbalance, for a rigid rotor. The two-dimensional repeatability and reproducibility of imbalance measurement are estimated by circles constructed from MANOVA-based method-of-moments and the results are compared to those of one-dimensional repeatability and reproducibility using the same measurement data. The results of both the one-dimensional and the two-dimensional repeatability and reproducibility are interpreted in terms of capability or how the measurement variation relates to rotor imbalance specification or tolerance.

AB - Recent statistical work is applied to measuring imbalance in a single plane, often referred to as static imbalance, for a rigid rotor. The two-dimensional repeatability and reproducibility of imbalance measurement are estimated by circles constructed from MANOVA-based method-of-moments and the results are compared to those of one-dimensional repeatability and reproducibility using the same measurement data. The results of both the one-dimensional and the two-dimensional repeatability and reproducibility are interpreted in terms of capability or how the measurement variation relates to rotor imbalance specification or tolerance.

UR - http://www.scopus.com/inward/record.url?scp=33845794841&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33845794841&partnerID=8YFLogxK

U2 - 10.1080/08982110601057641

DO - 10.1080/08982110601057641

M3 - Article

AN - SCOPUS:33845794841

VL - 19

SP - 29

EP - 37

JO - Quality Engineering

JF - Quality Engineering

SN - 0898-2112

IS - 1

ER -