Anesthesia for robotic repair of the mitral valve: A report of two cases

Nutan Mehta, Sumeet Goswami, Michael Argenziano, Craig R. Smith, Berend Mets

Research output: Contribution to journalArticle

5 Citations (Scopus)

Abstract

We describe the anesthetic management of two patients who underwent successful mitral valve repair with use of a robot-assisted cardiac surgical technique. We describe the robot used, as well as the surgical procedure, and highlight aspects of the anesthetic management, in particular the need for one-lung ventilation and the utility of transesophageal echocardiography.

Original languageEnglish (US)
Pages (from-to)7-10
Number of pages4
JournalAnesthesia and analgesia
Volume96
Issue number1
DOIs
StatePublished - Jan 1 2003

Fingerprint

Robotics
Mitral Valve
Anesthetics
Anesthesia
One-Lung Ventilation
Transesophageal Echocardiography

All Science Journal Classification (ASJC) codes

  • Anesthesiology and Pain Medicine

Cite this

Mehta, Nutan ; Goswami, Sumeet ; Argenziano, Michael ; Smith, Craig R. ; Mets, Berend. / Anesthesia for robotic repair of the mitral valve : A report of two cases. In: Anesthesia and analgesia. 2003 ; Vol. 96, No. 1. pp. 7-10.
@article{68db3de9195f42578bd4842b4ec0ec7b,
title = "Anesthesia for robotic repair of the mitral valve: A report of two cases",
abstract = "We describe the anesthetic management of two patients who underwent successful mitral valve repair with use of a robot-assisted cardiac surgical technique. We describe the robot used, as well as the surgical procedure, and highlight aspects of the anesthetic management, in particular the need for one-lung ventilation and the utility of transesophageal echocardiography.",
author = "Nutan Mehta and Sumeet Goswami and Michael Argenziano and Smith, {Craig R.} and Berend Mets",
year = "2003",
month = "1",
day = "1",
doi = "10.1097/00000539-200301000-00003",
language = "English (US)",
volume = "96",
pages = "7--10",
journal = "Anesthesia and Analgesia",
issn = "0003-2999",
publisher = "Lippincott Williams and Wilkins",
number = "1",

}

Anesthesia for robotic repair of the mitral valve : A report of two cases. / Mehta, Nutan; Goswami, Sumeet; Argenziano, Michael; Smith, Craig R.; Mets, Berend.

In: Anesthesia and analgesia, Vol. 96, No. 1, 01.01.2003, p. 7-10.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Anesthesia for robotic repair of the mitral valve

T2 - A report of two cases

AU - Mehta, Nutan

AU - Goswami, Sumeet

AU - Argenziano, Michael

AU - Smith, Craig R.

AU - Mets, Berend

PY - 2003/1/1

Y1 - 2003/1/1

N2 - We describe the anesthetic management of two patients who underwent successful mitral valve repair with use of a robot-assisted cardiac surgical technique. We describe the robot used, as well as the surgical procedure, and highlight aspects of the anesthetic management, in particular the need for one-lung ventilation and the utility of transesophageal echocardiography.

AB - We describe the anesthetic management of two patients who underwent successful mitral valve repair with use of a robot-assisted cardiac surgical technique. We describe the robot used, as well as the surgical procedure, and highlight aspects of the anesthetic management, in particular the need for one-lung ventilation and the utility of transesophageal echocardiography.

UR - http://www.scopus.com/inward/record.url?scp=0037223638&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0037223638&partnerID=8YFLogxK

U2 - 10.1097/00000539-200301000-00003

DO - 10.1097/00000539-200301000-00003

M3 - Article

C2 - 12505914

AN - SCOPUS:0037223638

VL - 96

SP - 7

EP - 10

JO - Anesthesia and Analgesia

JF - Anesthesia and Analgesia

SN - 0003-2999

IS - 1

ER -