Changes in the flexor digitorum profundus tendon geometry in the carpal tunnel due to force production and posture of metacarpophalangeal joint of the index finger: An MRI study

Joel R. Martin, Florent Paclet, Mark L. Latash, Vladimir M. Zatsiorsky

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

Background: Carpal tunnel syndrome is a disorder caused by increased pressure in the carpal tunnel associated with repetitive, stereotypical finger actions. Little is known about in vivo geometrical changes in the carpal tunnel caused by motion at the finger joints and exerting a fingertip force. Methods: The hands and forearms of five subjects were scanned using a 3.0 T magnetic resonance imaging scanner. The metacarpophalangeal joint of the index finger was placed in: flexion, neutral and extension. For each joint posture subjects either produced no active force (passive condition) or exerted a flexion force to resist a load (~ 4.0 N) at the fingertip (active condition). Changes in the radii of curvature, position and transverse plane area of the flexor digitorum profundus tendons at the carpal tunnel level were measured. Results: The radius of curvature of the flexor digitorum profundus tendons, at the carpal tunnel level, was significantly affected by posture of the index finger metacarpophalangeal joint (P < 0.05) and the radii was significantly different between fingers (P < 0.05). Actively producing force caused a significant shift (P < 0.05) in the flexor digitorum profundus tendons in the ventral (palmar) direction. No significant change in the area of an ellipse containing the flexor digitorum profundus tendons was observed between conditions. Interpretation: The results show that relatively small changes in the posture and force production of a single finger can lead to significant changes in the geometry of all the flexor digitorum profundus tendons in the carpal tunnel. Additionally, voluntary force production at the fingertip increases the moment arm of the FDP tendons about the wrist joint.

Original languageEnglish (US)
Pages (from-to)157-163
Number of pages7
JournalClinical Biomechanics
Volume28
Issue number2
DOIs
StatePublished - Feb 1 2013

Fingerprint

Metacarpophalangeal Joint
Wrist
Posture
Tendons
Fingers
Finger Joint
Wrist Joint
Carpal Tunnel Syndrome
Forearm
Hand
Joints
Magnetic Resonance Imaging
Pressure

All Science Journal Classification (ASJC) codes

  • Biophysics
  • Orthopedics and Sports Medicine

Cite this

@article{31c0948ff28c4b979e10d848af62f5a7,
title = "Changes in the flexor digitorum profundus tendon geometry in the carpal tunnel due to force production and posture of metacarpophalangeal joint of the index finger: An MRI study",
abstract = "Background: Carpal tunnel syndrome is a disorder caused by increased pressure in the carpal tunnel associated with repetitive, stereotypical finger actions. Little is known about in vivo geometrical changes in the carpal tunnel caused by motion at the finger joints and exerting a fingertip force. Methods: The hands and forearms of five subjects were scanned using a 3.0 T magnetic resonance imaging scanner. The metacarpophalangeal joint of the index finger was placed in: flexion, neutral and extension. For each joint posture subjects either produced no active force (passive condition) or exerted a flexion force to resist a load (~ 4.0 N) at the fingertip (active condition). Changes in the radii of curvature, position and transverse plane area of the flexor digitorum profundus tendons at the carpal tunnel level were measured. Results: The radius of curvature of the flexor digitorum profundus tendons, at the carpal tunnel level, was significantly affected by posture of the index finger metacarpophalangeal joint (P < 0.05) and the radii was significantly different between fingers (P < 0.05). Actively producing force caused a significant shift (P < 0.05) in the flexor digitorum profundus tendons in the ventral (palmar) direction. No significant change in the area of an ellipse containing the flexor digitorum profundus tendons was observed between conditions. Interpretation: The results show that relatively small changes in the posture and force production of a single finger can lead to significant changes in the geometry of all the flexor digitorum profundus tendons in the carpal tunnel. Additionally, voluntary force production at the fingertip increases the moment arm of the FDP tendons about the wrist joint.",
author = "Martin, {Joel R.} and Florent Paclet and Latash, {Mark L.} and Zatsiorsky, {Vladimir M.}",
year = "2013",
month = "2",
day = "1",
doi = "10.1016/j.clinbiomech.2012.11.004",
language = "English (US)",
volume = "28",
pages = "157--163",
journal = "Clinical Biomechanics",
issn = "0268-0033",
publisher = "Elsevier Limited",
number = "2",

}

Changes in the flexor digitorum profundus tendon geometry in the carpal tunnel due to force production and posture of metacarpophalangeal joint of the index finger : An MRI study. / Martin, Joel R.; Paclet, Florent; Latash, Mark L.; Zatsiorsky, Vladimir M.

In: Clinical Biomechanics, Vol. 28, No. 2, 01.02.2013, p. 157-163.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Changes in the flexor digitorum profundus tendon geometry in the carpal tunnel due to force production and posture of metacarpophalangeal joint of the index finger

T2 - An MRI study

AU - Martin, Joel R.

AU - Paclet, Florent

AU - Latash, Mark L.

AU - Zatsiorsky, Vladimir M.

PY - 2013/2/1

Y1 - 2013/2/1

N2 - Background: Carpal tunnel syndrome is a disorder caused by increased pressure in the carpal tunnel associated with repetitive, stereotypical finger actions. Little is known about in vivo geometrical changes in the carpal tunnel caused by motion at the finger joints and exerting a fingertip force. Methods: The hands and forearms of five subjects were scanned using a 3.0 T magnetic resonance imaging scanner. The metacarpophalangeal joint of the index finger was placed in: flexion, neutral and extension. For each joint posture subjects either produced no active force (passive condition) or exerted a flexion force to resist a load (~ 4.0 N) at the fingertip (active condition). Changes in the radii of curvature, position and transverse plane area of the flexor digitorum profundus tendons at the carpal tunnel level were measured. Results: The radius of curvature of the flexor digitorum profundus tendons, at the carpal tunnel level, was significantly affected by posture of the index finger metacarpophalangeal joint (P < 0.05) and the radii was significantly different between fingers (P < 0.05). Actively producing force caused a significant shift (P < 0.05) in the flexor digitorum profundus tendons in the ventral (palmar) direction. No significant change in the area of an ellipse containing the flexor digitorum profundus tendons was observed between conditions. Interpretation: The results show that relatively small changes in the posture and force production of a single finger can lead to significant changes in the geometry of all the flexor digitorum profundus tendons in the carpal tunnel. Additionally, voluntary force production at the fingertip increases the moment arm of the FDP tendons about the wrist joint.

AB - Background: Carpal tunnel syndrome is a disorder caused by increased pressure in the carpal tunnel associated with repetitive, stereotypical finger actions. Little is known about in vivo geometrical changes in the carpal tunnel caused by motion at the finger joints and exerting a fingertip force. Methods: The hands and forearms of five subjects were scanned using a 3.0 T magnetic resonance imaging scanner. The metacarpophalangeal joint of the index finger was placed in: flexion, neutral and extension. For each joint posture subjects either produced no active force (passive condition) or exerted a flexion force to resist a load (~ 4.0 N) at the fingertip (active condition). Changes in the radii of curvature, position and transverse plane area of the flexor digitorum profundus tendons at the carpal tunnel level were measured. Results: The radius of curvature of the flexor digitorum profundus tendons, at the carpal tunnel level, was significantly affected by posture of the index finger metacarpophalangeal joint (P < 0.05) and the radii was significantly different between fingers (P < 0.05). Actively producing force caused a significant shift (P < 0.05) in the flexor digitorum profundus tendons in the ventral (palmar) direction. No significant change in the area of an ellipse containing the flexor digitorum profundus tendons was observed between conditions. Interpretation: The results show that relatively small changes in the posture and force production of a single finger can lead to significant changes in the geometry of all the flexor digitorum profundus tendons in the carpal tunnel. Additionally, voluntary force production at the fingertip increases the moment arm of the FDP tendons about the wrist joint.

UR - http://www.scopus.com/inward/record.url?scp=84875756576&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84875756576&partnerID=8YFLogxK

U2 - 10.1016/j.clinbiomech.2012.11.004

DO - 10.1016/j.clinbiomech.2012.11.004

M3 - Article

C2 - 23219762

AN - SCOPUS:84875756576

VL - 28

SP - 157

EP - 163

JO - Clinical Biomechanics

JF - Clinical Biomechanics

SN - 0268-0033

IS - 2

ER -