Characterization of food colloids by phase analysis light scattering

S. Vanapalli, J. N. Coupland

Research output: Contribution to journalArticle

18 Citations (Scopus)

Abstract

Recently a novel technique, phase analysis light scattering (PALS), has been developed to measure the electrophoretic mobility of charged particles that offers enhanced sensitivity at the low mobilities, typical of many food colloids. The principles of this technique are discussed in comparison to conventional laser Doppler electrophoresis (LDE). A sample of whey protein isolate solution (10 wt%) was titrated with HCl (0.1 M) and the electrophoretic mobility measured by PALS and LDE. Both methods showed an increase in electrophoretic mobility with pH, but PALS yielded better reproducibility. In addition, PALS could be used to measure the isoelectric point of the protein mixture as the pH where the mobility was zero. (C) 2000 Elsevier Science Ltd.

Original languageEnglish (US)
Pages (from-to)315-317
Number of pages3
JournalFood Hydrocolloids
Volume14
Issue number4
DOIs
StatePublished - Jan 1 2000

Fingerprint

colloids
Colloids
light scattering
Light scattering
Electrophoretic mobility
Light
Food
Electrophoresis
electrophoresis
lasers
Lasers
Proteins
whey protein isolate
Isoelectric Point
Charged particles
isoelectric point
reproducibility
methodology
proteins
sampling

All Science Journal Classification (ASJC) codes

  • Food Science
  • Chemistry(all)
  • Chemical Engineering(all)

Cite this

@article{fcee6247a9ff499a8d709fe36909eee8,
title = "Characterization of food colloids by phase analysis light scattering",
abstract = "Recently a novel technique, phase analysis light scattering (PALS), has been developed to measure the electrophoretic mobility of charged particles that offers enhanced sensitivity at the low mobilities, typical of many food colloids. The principles of this technique are discussed in comparison to conventional laser Doppler electrophoresis (LDE). A sample of whey protein isolate solution (10 wt{\%}) was titrated with HCl (0.1 M) and the electrophoretic mobility measured by PALS and LDE. Both methods showed an increase in electrophoretic mobility with pH, but PALS yielded better reproducibility. In addition, PALS could be used to measure the isoelectric point of the protein mixture as the pH where the mobility was zero. (C) 2000 Elsevier Science Ltd.",
author = "S. Vanapalli and Coupland, {J. N.}",
year = "2000",
month = "1",
day = "1",
doi = "10.1016/S0268-005X(00)00006-0",
language = "English (US)",
volume = "14",
pages = "315--317",
journal = "Food Hydrocolloids",
issn = "0268-005X",
publisher = "Elsevier",
number = "4",

}

Characterization of food colloids by phase analysis light scattering. / Vanapalli, S.; Coupland, J. N.

In: Food Hydrocolloids, Vol. 14, No. 4, 01.01.2000, p. 315-317.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Characterization of food colloids by phase analysis light scattering

AU - Vanapalli, S.

AU - Coupland, J. N.

PY - 2000/1/1

Y1 - 2000/1/1

N2 - Recently a novel technique, phase analysis light scattering (PALS), has been developed to measure the electrophoretic mobility of charged particles that offers enhanced sensitivity at the low mobilities, typical of many food colloids. The principles of this technique are discussed in comparison to conventional laser Doppler electrophoresis (LDE). A sample of whey protein isolate solution (10 wt%) was titrated with HCl (0.1 M) and the electrophoretic mobility measured by PALS and LDE. Both methods showed an increase in electrophoretic mobility with pH, but PALS yielded better reproducibility. In addition, PALS could be used to measure the isoelectric point of the protein mixture as the pH where the mobility was zero. (C) 2000 Elsevier Science Ltd.

AB - Recently a novel technique, phase analysis light scattering (PALS), has been developed to measure the electrophoretic mobility of charged particles that offers enhanced sensitivity at the low mobilities, typical of many food colloids. The principles of this technique are discussed in comparison to conventional laser Doppler electrophoresis (LDE). A sample of whey protein isolate solution (10 wt%) was titrated with HCl (0.1 M) and the electrophoretic mobility measured by PALS and LDE. Both methods showed an increase in electrophoretic mobility with pH, but PALS yielded better reproducibility. In addition, PALS could be used to measure the isoelectric point of the protein mixture as the pH where the mobility was zero. (C) 2000 Elsevier Science Ltd.

UR - http://www.scopus.com/inward/record.url?scp=0033832524&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0033832524&partnerID=8YFLogxK

U2 - 10.1016/S0268-005X(00)00006-0

DO - 10.1016/S0268-005X(00)00006-0

M3 - Article

AN - SCOPUS:0033832524

VL - 14

SP - 315

EP - 317

JO - Food Hydrocolloids

JF - Food Hydrocolloids

SN - 0268-005X

IS - 4

ER -