Comparison of two radioimmunoassay kits for aldosterone determination

Eric J. Sampson, Dennis D. Derck, Laurence Demers

Research output: Contribution to journalArticle

10 Citations (Scopus)

Abstract

Two commercially available radioimmunoassay kits for aldosterone determination not requiring preliminary chromatographic purification were examined. Aldosterone standard curve solutions prepared from the CIS kit, Nuclear International Corp., (x-axis) and Diagnostic Products kit (y-axis) were assayed with both kits and the results yielded a regression equation of y = 0.834x + 0.08 nmol/ liter. Analytical recovery experiments with aldosterone added to urine and serum showed 120% and 101% recovery with the CIS kit, respectively, and 92% and 92% recovery with the Diagnostic Products kit, respectively. Both kits demonstrated good parallelism with urine and serum. Antibody specificity was tested with six structurally related steroids and each kit showed virtually no crossreactivity at clinically normal serum concentrations. Serum aldosterone values were compared before (y-axis) and after (x-axis) column chromatography on Sephadex LH-20, with the following regression equations: y = 1.070x + 0.092 nmol/liter for the CIS kit and y = 1.023x + 0.093 nmol/liter for the Diagnostic Products kit. Regression equations comparing patient samples between kits, CIS (x-axis) and Diagnostic Products (y-axis), were: y = 0.832x + 0.007 μmol/24 h with urine and y = 0.850x + 0.097 nmol/liter with serum.

Original languageEnglish (US)
Pages (from-to)216-221
Number of pages6
JournalClinical Biochemistry
Volume9
Issue numberC
DOIs
StatePublished - Jan 1 1976

Fingerprint

Diagnostic products
Aldosterone
Radioimmunoassay
Serum
Recovery
Urine
Column chromatography
Antibody Specificity
Purification
Steroids
Chromatography
Antibodies
Experiments

All Science Journal Classification (ASJC) codes

  • Clinical Biochemistry

Cite this

Sampson, Eric J. ; Derck, Dennis D. ; Demers, Laurence. / Comparison of two radioimmunoassay kits for aldosterone determination. In: Clinical Biochemistry. 1976 ; Vol. 9, No. C. pp. 216-221.
@article{562df45c5c2a48c89452b5a3c620ffbb,
title = "Comparison of two radioimmunoassay kits for aldosterone determination",
abstract = "Two commercially available radioimmunoassay kits for aldosterone determination not requiring preliminary chromatographic purification were examined. Aldosterone standard curve solutions prepared from the CIS kit, Nuclear International Corp., (x-axis) and Diagnostic Products kit (y-axis) were assayed with both kits and the results yielded a regression equation of y = 0.834x + 0.08 nmol/ liter. Analytical recovery experiments with aldosterone added to urine and serum showed 120{\%} and 101{\%} recovery with the CIS kit, respectively, and 92{\%} and 92{\%} recovery with the Diagnostic Products kit, respectively. Both kits demonstrated good parallelism with urine and serum. Antibody specificity was tested with six structurally related steroids and each kit showed virtually no crossreactivity at clinically normal serum concentrations. Serum aldosterone values were compared before (y-axis) and after (x-axis) column chromatography on Sephadex LH-20, with the following regression equations: y = 1.070x + 0.092 nmol/liter for the CIS kit and y = 1.023x + 0.093 nmol/liter for the Diagnostic Products kit. Regression equations comparing patient samples between kits, CIS (x-axis) and Diagnostic Products (y-axis), were: y = 0.832x + 0.007 μmol/24 h with urine and y = 0.850x + 0.097 nmol/liter with serum.",
author = "Sampson, {Eric J.} and Derck, {Dennis D.} and Laurence Demers",
year = "1976",
month = "1",
day = "1",
doi = "10.1016/S0009-9120(76)80061-6",
language = "English (US)",
volume = "9",
pages = "216--221",
journal = "Clinical Biochemistry",
issn = "0009-9120",
publisher = "Elsevier Inc.",
number = "C",

}

Comparison of two radioimmunoassay kits for aldosterone determination. / Sampson, Eric J.; Derck, Dennis D.; Demers, Laurence.

In: Clinical Biochemistry, Vol. 9, No. C, 01.01.1976, p. 216-221.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Comparison of two radioimmunoassay kits for aldosterone determination

AU - Sampson, Eric J.

AU - Derck, Dennis D.

AU - Demers, Laurence

PY - 1976/1/1

Y1 - 1976/1/1

N2 - Two commercially available radioimmunoassay kits for aldosterone determination not requiring preliminary chromatographic purification were examined. Aldosterone standard curve solutions prepared from the CIS kit, Nuclear International Corp., (x-axis) and Diagnostic Products kit (y-axis) were assayed with both kits and the results yielded a regression equation of y = 0.834x + 0.08 nmol/ liter. Analytical recovery experiments with aldosterone added to urine and serum showed 120% and 101% recovery with the CIS kit, respectively, and 92% and 92% recovery with the Diagnostic Products kit, respectively. Both kits demonstrated good parallelism with urine and serum. Antibody specificity was tested with six structurally related steroids and each kit showed virtually no crossreactivity at clinically normal serum concentrations. Serum aldosterone values were compared before (y-axis) and after (x-axis) column chromatography on Sephadex LH-20, with the following regression equations: y = 1.070x + 0.092 nmol/liter for the CIS kit and y = 1.023x + 0.093 nmol/liter for the Diagnostic Products kit. Regression equations comparing patient samples between kits, CIS (x-axis) and Diagnostic Products (y-axis), were: y = 0.832x + 0.007 μmol/24 h with urine and y = 0.850x + 0.097 nmol/liter with serum.

AB - Two commercially available radioimmunoassay kits for aldosterone determination not requiring preliminary chromatographic purification were examined. Aldosterone standard curve solutions prepared from the CIS kit, Nuclear International Corp., (x-axis) and Diagnostic Products kit (y-axis) were assayed with both kits and the results yielded a regression equation of y = 0.834x + 0.08 nmol/ liter. Analytical recovery experiments with aldosterone added to urine and serum showed 120% and 101% recovery with the CIS kit, respectively, and 92% and 92% recovery with the Diagnostic Products kit, respectively. Both kits demonstrated good parallelism with urine and serum. Antibody specificity was tested with six structurally related steroids and each kit showed virtually no crossreactivity at clinically normal serum concentrations. Serum aldosterone values were compared before (y-axis) and after (x-axis) column chromatography on Sephadex LH-20, with the following regression equations: y = 1.070x + 0.092 nmol/liter for the CIS kit and y = 1.023x + 0.093 nmol/liter for the Diagnostic Products kit. Regression equations comparing patient samples between kits, CIS (x-axis) and Diagnostic Products (y-axis), were: y = 0.832x + 0.007 μmol/24 h with urine and y = 0.850x + 0.097 nmol/liter with serum.

UR - http://www.scopus.com/inward/record.url?scp=0017101214&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0017101214&partnerID=8YFLogxK

U2 - 10.1016/S0009-9120(76)80061-6

DO - 10.1016/S0009-9120(76)80061-6

M3 - Article

C2 - 954186

AN - SCOPUS:0017101214

VL - 9

SP - 216

EP - 221

JO - Clinical Biochemistry

JF - Clinical Biochemistry

SN - 0009-9120

IS - C