This work was supported primarily by the Commercial Building Integration program of the Building Technologies Office, within the U.S. Department of Energy's Office of Energy Efficiency and Renewable Energy, via contract DE‐AC02‐05CH11231. Additional support was provided by the Indoor Environments Division of the U.S. Environmental Protection Agency via Interagency Agreement DW‐89‐9232201‐7. The aerosol modeling work was supported by the U.S. Department of Energy Office of Science, through the National Virtual Biotechnology Laboratory, a consortium of DOE national laboratories focused on response to COVID‐19, with funding provided by the Coronavirus CARES Act.
Publisher Copyright:
© 2021 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd
PY - 2022/1
Y1 - 2022/1
N2 - The evolution of SARS-CoV-2 virus has resulted in variants likely to be more readily transmitted through respiratory aerosols, underscoring the increased potential for indoor environmental controls to mitigate risk. Use of tight-fitting face masks to trap infectious aerosol in exhaled breath and reduce inhalation exposure to contaminated air is of critical importance for disease control. Administrative controls including the regulation of occupancy and interpersonal spacing are also important, while presenting social and economic challenges. Indoor engineering controls including ventilation, exhaust, air flow control, filtration, and disinfection by germicidal ultraviolet irradiation can reduce reliance on stringent occupancy restrictions. However, the effects of controls—individually and in combination—on reducing infectious aerosol transfer indoors remain to be clearly characterized to the extent needed to support widespread implementation by building operators. We review aerobiologic and epidemiologic evidence of indoor environmental controls against transmission and present a quantitative aerosol transfer scenario illustrating relative differences in exposure at close-interactive, room, and building scales. We identify an overarching need for investment to implement building controls and evaluate their effectiveness on infection in well-characterized and real-world settings, supported by specific, methodological advances. Improved understanding of engineering control effectiveness guides implementation at scale while considering occupant comfort, operational challenges, and energy costs.
AB - The evolution of SARS-CoV-2 virus has resulted in variants likely to be more readily transmitted through respiratory aerosols, underscoring the increased potential for indoor environmental controls to mitigate risk. Use of tight-fitting face masks to trap infectious aerosol in exhaled breath and reduce inhalation exposure to contaminated air is of critical importance for disease control. Administrative controls including the regulation of occupancy and interpersonal spacing are also important, while presenting social and economic challenges. Indoor engineering controls including ventilation, exhaust, air flow control, filtration, and disinfection by germicidal ultraviolet irradiation can reduce reliance on stringent occupancy restrictions. However, the effects of controls—individually and in combination—on reducing infectious aerosol transfer indoors remain to be clearly characterized to the extent needed to support widespread implementation by building operators. We review aerobiologic and epidemiologic evidence of indoor environmental controls against transmission and present a quantitative aerosol transfer scenario illustrating relative differences in exposure at close-interactive, room, and building scales. We identify an overarching need for investment to implement building controls and evaluate their effectiveness on infection in well-characterized and real-world settings, supported by specific, methodological advances. Improved understanding of engineering control effectiveness guides implementation at scale while considering occupant comfort, operational challenges, and energy costs.
UR - http://www.scopus.com/inward/record.url?scp=85119653772&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85119653772&partnerID=8YFLogxK
U2 - 10.1111/ina.12965
DO - 10.1111/ina.12965
M3 - Review article
C2 - 34816493
AN - SCOPUS:85119653772
VL - 32
JO - Indoor Air
JF - Indoor Air
SN - 0905-6947
IS - 1
M1 - e12965
ER -