N2 - Metrology applications commonly require non-contact, capacitive sensors for displacement measurements due to their nanometer resolution. In some metrology applications, for example, the measurement of roundness and spindle error motion, the displacements of stationary and rotating cylindrical artifacts are measured. Error from using a conventionally calibrated sensor with a non-flat (e.g., cylindrical) target is typically neglected, but these errors cannot be ignored for nanometer-level accuracy. The capacitance between a sensor and a cylindrical target is less than that of a sensor with a flat target, which causes four effects. As the diameter of the target shrinks, the sensitivity of the sensor increases, the sensing range decreases, the sensing range shifts towards the target, and the nonlinearity increases. These errors can be greatly reduced by either calibrating sensors with the correct target surface or by determining corrections for post-processing data. This paper quantifies and experimentally verifies these errors for a commonly used sensor, and a simulation of a nanometer-level measurement of out-of-roundness and spindle error motion demonstrates that measurement accuracy is improved with corrected sensitivities.
AB - Metrology applications commonly require non-contact, capacitive sensors for displacement measurements due to their nanometer resolution. In some metrology applications, for example, the measurement of roundness and spindle error motion, the displacements of stationary and rotating cylindrical artifacts are measured. Error from using a conventionally calibrated sensor with a non-flat (e.g., cylindrical) target is typically neglected, but these errors cannot be ignored for nanometer-level accuracy. The capacitance between a sensor and a cylindrical target is less than that of a sensor with a flat target, which causes four effects. As the diameter of the target shrinks, the sensitivity of the sensor increases, the sensing range decreases, the sensing range shifts towards the target, and the nonlinearity increases. These errors can be greatly reduced by either calibrating sensors with the correct target surface or by determining corrections for post-processing data. This paper quantifies and experimentally verifies these errors for a commonly used sensor, and a simulation of a nanometer-level measurement of out-of-roundness and spindle error motion demonstrates that measurement accuracy is improved with corrected sensitivities.
UR - http://www.scopus.com/inward/record.url?scp=19944412153&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=19944412153&partnerID=8YFLogxK
U2 - 10.1016/j.precisioneng.2004.11.010
DO - 10.1016/j.precisioneng.2004.11.010
M3 - Article
AN - SCOPUS:19944412153
SN - 0141-6359
VL - 29
SP - 324
EP - 335
JO - Precision Engineering
JF - Precision Engineering
IS - 3
ER -