Correcting porewater concentration measurements from peepers

Application of a reverse tracer

Burt Thomas, Michael Allan Arthur

Research output: Contribution to journalArticle

5 Citations (Scopus)

Abstract

This work describes the routine application of a reverse tracer to passive diffusion sampler deployments. The reverse tracer provides evidence of the extent of equilibrium for any peeper cell and an indication of the diffusivity change with depth associated with physical changes in the sediment. Quantitative measurement of the reverse tracer also allows for the correction of measured data within cells that may not have reached chemical equilibrium, thereby removing the requirement of a priori knowledge of the time to concentration equilibrium. Investigations that use ion chromatographic techniques that incidentally measure Br- or other conservative tracers can apply this method with no additional analytical requirements. Our approach opens up peeper applications to shorter duration deployments as required for marine sediment sampled by submersibles and deployments in environments with uncertain or unknown equilibration times such as highly heterogeneous sediments. We present a novel peeper design as well as the theory and application of this technique along with an example from a field deployment. We conclude that corrections that assume a simple approximation of exponential tracer decay are a considerable improvement over the reliance on observed measured values from porewater dialysis samplers. Moreover, even without using the reverse tracer to correct measured cell concentrations, the reverse tracer can point to significant divergences from concentration equilibrium and is useful to determine which cell measurements should be discarded.

Original languageEnglish (US)
Pages (from-to)403-413
Number of pages11
JournalLimnology and Oceanography: Methods
Volume8
Issue numberAUG
DOIs
StatePublished - Aug 1 2010

Fingerprint

Sediments
Submersibles
Dialysis
Ions

All Science Journal Classification (ASJC) codes

  • Ocean Engineering

Cite this

@article{5f08317b970c472a9e28098fe471d4e5,
title = "Correcting porewater concentration measurements from peepers: Application of a reverse tracer",
abstract = "This work describes the routine application of a reverse tracer to passive diffusion sampler deployments. The reverse tracer provides evidence of the extent of equilibrium for any peeper cell and an indication of the diffusivity change with depth associated with physical changes in the sediment. Quantitative measurement of the reverse tracer also allows for the correction of measured data within cells that may not have reached chemical equilibrium, thereby removing the requirement of a priori knowledge of the time to concentration equilibrium. Investigations that use ion chromatographic techniques that incidentally measure Br- or other conservative tracers can apply this method with no additional analytical requirements. Our approach opens up peeper applications to shorter duration deployments as required for marine sediment sampled by submersibles and deployments in environments with uncertain or unknown equilibration times such as highly heterogeneous sediments. We present a novel peeper design as well as the theory and application of this technique along with an example from a field deployment. We conclude that corrections that assume a simple approximation of exponential tracer decay are a considerable improvement over the reliance on observed measured values from porewater dialysis samplers. Moreover, even without using the reverse tracer to correct measured cell concentrations, the reverse tracer can point to significant divergences from concentration equilibrium and is useful to determine which cell measurements should be discarded.",
author = "Burt Thomas and Arthur, {Michael Allan}",
year = "2010",
month = "8",
day = "1",
doi = "10.4319/lom.2010.8.403",
language = "English (US)",
volume = "8",
pages = "403--413",
journal = "Limnology and Oceanography: Methods",
issn = "1541-5856",
publisher = "American Society of Limnology and Oceanography Inc.",
number = "AUG",

}

Correcting porewater concentration measurements from peepers : Application of a reverse tracer. / Thomas, Burt; Arthur, Michael Allan.

In: Limnology and Oceanography: Methods, Vol. 8, No. AUG, 01.08.2010, p. 403-413.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Correcting porewater concentration measurements from peepers

T2 - Application of a reverse tracer

AU - Thomas, Burt

AU - Arthur, Michael Allan

PY - 2010/8/1

Y1 - 2010/8/1

N2 - This work describes the routine application of a reverse tracer to passive diffusion sampler deployments. The reverse tracer provides evidence of the extent of equilibrium for any peeper cell and an indication of the diffusivity change with depth associated with physical changes in the sediment. Quantitative measurement of the reverse tracer also allows for the correction of measured data within cells that may not have reached chemical equilibrium, thereby removing the requirement of a priori knowledge of the time to concentration equilibrium. Investigations that use ion chromatographic techniques that incidentally measure Br- or other conservative tracers can apply this method with no additional analytical requirements. Our approach opens up peeper applications to shorter duration deployments as required for marine sediment sampled by submersibles and deployments in environments with uncertain or unknown equilibration times such as highly heterogeneous sediments. We present a novel peeper design as well as the theory and application of this technique along with an example from a field deployment. We conclude that corrections that assume a simple approximation of exponential tracer decay are a considerable improvement over the reliance on observed measured values from porewater dialysis samplers. Moreover, even without using the reverse tracer to correct measured cell concentrations, the reverse tracer can point to significant divergences from concentration equilibrium and is useful to determine which cell measurements should be discarded.

AB - This work describes the routine application of a reverse tracer to passive diffusion sampler deployments. The reverse tracer provides evidence of the extent of equilibrium for any peeper cell and an indication of the diffusivity change with depth associated with physical changes in the sediment. Quantitative measurement of the reverse tracer also allows for the correction of measured data within cells that may not have reached chemical equilibrium, thereby removing the requirement of a priori knowledge of the time to concentration equilibrium. Investigations that use ion chromatographic techniques that incidentally measure Br- or other conservative tracers can apply this method with no additional analytical requirements. Our approach opens up peeper applications to shorter duration deployments as required for marine sediment sampled by submersibles and deployments in environments with uncertain or unknown equilibration times such as highly heterogeneous sediments. We present a novel peeper design as well as the theory and application of this technique along with an example from a field deployment. We conclude that corrections that assume a simple approximation of exponential tracer decay are a considerable improvement over the reliance on observed measured values from porewater dialysis samplers. Moreover, even without using the reverse tracer to correct measured cell concentrations, the reverse tracer can point to significant divergences from concentration equilibrium and is useful to determine which cell measurements should be discarded.

UR - http://www.scopus.com/inward/record.url?scp=77956738031&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77956738031&partnerID=8YFLogxK

U2 - 10.4319/lom.2010.8.403

DO - 10.4319/lom.2010.8.403

M3 - Article

VL - 8

SP - 403

EP - 413

JO - Limnology and Oceanography: Methods

JF - Limnology and Oceanography: Methods

SN - 1541-5856

IS - AUG

ER -