CT angiographic measurement of the carotid artery: Optimizing visualization by manipulating window and level settings and contrast material attenuation

Y. Liu, K. D. Hopper, D. T. Mauger, K. A. Addis

Research output: Contribution to journalArticle

44 Citations (Scopus)

Abstract

PURPOSE: To evaluate a broad range of window and level settings for various contrast material attenuation coefficients and degrees of vascular stenosis to obtain the most accurate computed tomographic (CT) angiographic measurements. MATERIALS AND METHODS: A total of 25,480 measurements were made transversely (perpendicular to the lumen) and by means of maximum intensity projection (MIP) in a phantom with stenoses of 0%-100%, contrast material with attenuation coefficients of 150-350 HU, and 14 window and 13 level settings. Edge definition was also evaluated. RESULTS: There was an inherent relationship between the contrast material attenuation coefficient and the optimal window and level settings in the measurement of stenoses at both transverse and MIP CT angiography. This relationship between the contrast material attenuation coefficient D and the optimal settings for window W and level L was represented by the following simple equations: W/D = [-2 x (L/D)] + 1.3, where -0.2 < L/D < 0.5, and W/D = [3.3 x (L/D)] - 1.3, where 0.5 < L/D < 1.0. With a vascular contrast material attenuation coefficient of 250-350 HU, the best transverse and MIP display settings for the window and level were 96 and 150 HU, respectively. CONCLUSION: The use of optimized window and level settings at CT angiography reduces measurement variability.

Original languageEnglish (US)
Pages (from-to)494-500
Number of pages7
JournalRadiology
Volume217
Issue number2
DOIs
StatePublished - Jan 1 2000

Fingerprint

Carotid Arteries
Contrast Media
Pathologic Constriction
Blood Vessels
Angiography

All Science Journal Classification (ASJC) codes

  • Radiology Nuclear Medicine and imaging

Cite this

@article{f31c7ad7eb5a4729a41cab85d2f5d6ad,
title = "CT angiographic measurement of the carotid artery: Optimizing visualization by manipulating window and level settings and contrast material attenuation",
abstract = "PURPOSE: To evaluate a broad range of window and level settings for various contrast material attenuation coefficients and degrees of vascular stenosis to obtain the most accurate computed tomographic (CT) angiographic measurements. MATERIALS AND METHODS: A total of 25,480 measurements were made transversely (perpendicular to the lumen) and by means of maximum intensity projection (MIP) in a phantom with stenoses of 0{\%}-100{\%}, contrast material with attenuation coefficients of 150-350 HU, and 14 window and 13 level settings. Edge definition was also evaluated. RESULTS: There was an inherent relationship between the contrast material attenuation coefficient and the optimal window and level settings in the measurement of stenoses at both transverse and MIP CT angiography. This relationship between the contrast material attenuation coefficient D and the optimal settings for window W and level L was represented by the following simple equations: W/D = [-2 x (L/D)] + 1.3, where -0.2 < L/D < 0.5, and W/D = [3.3 x (L/D)] - 1.3, where 0.5 < L/D < 1.0. With a vascular contrast material attenuation coefficient of 250-350 HU, the best transverse and MIP display settings for the window and level were 96 and 150 HU, respectively. CONCLUSION: The use of optimized window and level settings at CT angiography reduces measurement variability.",
author = "Y. Liu and Hopper, {K. D.} and Mauger, {D. T.} and Addis, {K. A.}",
year = "2000",
month = "1",
day = "1",
doi = "10.1148/radiology.217.2.r00oc32494",
language = "English (US)",
volume = "217",
pages = "494--500",
journal = "Radiology",
issn = "0033-8419",
publisher = "Radiological Society of North America Inc.",
number = "2",

}

CT angiographic measurement of the carotid artery : Optimizing visualization by manipulating window and level settings and contrast material attenuation. / Liu, Y.; Hopper, K. D.; Mauger, D. T.; Addis, K. A.

In: Radiology, Vol. 217, No. 2, 01.01.2000, p. 494-500.

Research output: Contribution to journalArticle

TY - JOUR

T1 - CT angiographic measurement of the carotid artery

T2 - Optimizing visualization by manipulating window and level settings and contrast material attenuation

AU - Liu, Y.

AU - Hopper, K. D.

AU - Mauger, D. T.

AU - Addis, K. A.

PY - 2000/1/1

Y1 - 2000/1/1

N2 - PURPOSE: To evaluate a broad range of window and level settings for various contrast material attenuation coefficients and degrees of vascular stenosis to obtain the most accurate computed tomographic (CT) angiographic measurements. MATERIALS AND METHODS: A total of 25,480 measurements were made transversely (perpendicular to the lumen) and by means of maximum intensity projection (MIP) in a phantom with stenoses of 0%-100%, contrast material with attenuation coefficients of 150-350 HU, and 14 window and 13 level settings. Edge definition was also evaluated. RESULTS: There was an inherent relationship between the contrast material attenuation coefficient and the optimal window and level settings in the measurement of stenoses at both transverse and MIP CT angiography. This relationship between the contrast material attenuation coefficient D and the optimal settings for window W and level L was represented by the following simple equations: W/D = [-2 x (L/D)] + 1.3, where -0.2 < L/D < 0.5, and W/D = [3.3 x (L/D)] - 1.3, where 0.5 < L/D < 1.0. With a vascular contrast material attenuation coefficient of 250-350 HU, the best transverse and MIP display settings for the window and level were 96 and 150 HU, respectively. CONCLUSION: The use of optimized window and level settings at CT angiography reduces measurement variability.

AB - PURPOSE: To evaluate a broad range of window and level settings for various contrast material attenuation coefficients and degrees of vascular stenosis to obtain the most accurate computed tomographic (CT) angiographic measurements. MATERIALS AND METHODS: A total of 25,480 measurements were made transversely (perpendicular to the lumen) and by means of maximum intensity projection (MIP) in a phantom with stenoses of 0%-100%, contrast material with attenuation coefficients of 150-350 HU, and 14 window and 13 level settings. Edge definition was also evaluated. RESULTS: There was an inherent relationship between the contrast material attenuation coefficient and the optimal window and level settings in the measurement of stenoses at both transverse and MIP CT angiography. This relationship between the contrast material attenuation coefficient D and the optimal settings for window W and level L was represented by the following simple equations: W/D = [-2 x (L/D)] + 1.3, where -0.2 < L/D < 0.5, and W/D = [3.3 x (L/D)] - 1.3, where 0.5 < L/D < 1.0. With a vascular contrast material attenuation coefficient of 250-350 HU, the best transverse and MIP display settings for the window and level were 96 and 150 HU, respectively. CONCLUSION: The use of optimized window and level settings at CT angiography reduces measurement variability.

UR - http://www.scopus.com/inward/record.url?scp=0033752855&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0033752855&partnerID=8YFLogxK

U2 - 10.1148/radiology.217.2.r00oc32494

DO - 10.1148/radiology.217.2.r00oc32494

M3 - Article

C2 - 11058651

AN - SCOPUS:0033752855

VL - 217

SP - 494

EP - 500

JO - Radiology

JF - Radiology

SN - 0033-8419

IS - 2

ER -