This paper describes the novel design of an ultrasonic normal beam transducer for prolonged use in elevated temperature environments. Through the use of a carbonl carbon composite backing layer, prolonged exposure to elevated temperature had minimal effect on transducer performance. The conductive nature of the carbon/carbon allowed for an innovative electrical coupling technique. A clamping mechanism combined with the use of an annealed gold quarter wave matching layer allowed for joint- free, dry coupling. This simple design allows for easy field assembly and eliminates temperature dependencies in the acoustic coupling. The transducer was tested initially at room temperature for reference data. Further tests after 100+ h of exposure to a 351 K environment showed little overall change in the transducer performance. The transducer showed consistent -6 dB bandwidths on the order of 54 to 67%, along with negligible change in centerline frequency. The insertion loss as a function of temperature showed an increase from approximately 6.8 to 8.5 dB over a temperature range from 298 to 358 K. Regression lines show bandwidth changes of -0.01% per 1 K and insertion loss changes of 0.03 dB per 1 K. These results show potential use for a transducer of this design at even higher temperatures.

Original languageEnglish (US)
Pages149-153
Number of pages5
Volume67
No2
Specialist publicationMaterials Evaluation
StatePublished - Feb 1 2009

Fingerprint

Transducers
Carbon
Temperature
Insertion losses
Bandwidth
Gold
Ultrasonics
Acoustics
Composite materials

All Science Journal Classification (ASJC) codes

  • Materials Science(all)
  • Mechanics of Materials
  • Mechanical Engineering

Cite this

Pedrick, M. ; Tittmann, B. R. ; Seliga, J. / Design and performance of a broadband 10 MHz transducer for elevated temperature, leave-in-place applications. In: Materials Evaluation. 2009 ; Vol. 67, No. 2. pp. 149-153.
@misc{a2b4e96a00664963b4f3df2204e11863,
title = "Design and performance of a broadband 10 MHz transducer for elevated temperature, leave-in-place applications",
abstract = "This paper describes the novel design of an ultrasonic normal beam transducer for prolonged use in elevated temperature environments. Through the use of a carbonl carbon composite backing layer, prolonged exposure to elevated temperature had minimal effect on transducer performance. The conductive nature of the carbon/carbon allowed for an innovative electrical coupling technique. A clamping mechanism combined with the use of an annealed gold quarter wave matching layer allowed for joint- free, dry coupling. This simple design allows for easy field assembly and eliminates temperature dependencies in the acoustic coupling. The transducer was tested initially at room temperature for reference data. Further tests after 100+ h of exposure to a 351 K environment showed little overall change in the transducer performance. The transducer showed consistent -6 dB bandwidths on the order of 54 to 67{\%}, along with negligible change in centerline frequency. The insertion loss as a function of temperature showed an increase from approximately 6.8 to 8.5 dB over a temperature range from 298 to 358 K. Regression lines show bandwidth changes of -0.01{\%} per 1 K and insertion loss changes of 0.03 dB per 1 K. These results show potential use for a transducer of this design at even higher temperatures.",
author = "M. Pedrick and Tittmann, {B. R.} and J. Seliga",
year = "2009",
month = "2",
day = "1",
language = "English (US)",
volume = "67",
pages = "149--153",
journal = "Materials Evaluation",
issn = "0025-5327",
publisher = "American Society for Nondestructive Testing",

}

Design and performance of a broadband 10 MHz transducer for elevated temperature, leave-in-place applications. / Pedrick, M.; Tittmann, B. R.; Seliga, J.

In: Materials Evaluation, Vol. 67, No. 2, 01.02.2009, p. 149-153.

Research output: Contribution to specialist publicationArticle

TY - GEN

T1 - Design and performance of a broadband 10 MHz transducer for elevated temperature, leave-in-place applications

AU - Pedrick, M.

AU - Tittmann, B. R.

AU - Seliga, J.

PY - 2009/2/1

Y1 - 2009/2/1

N2 - This paper describes the novel design of an ultrasonic normal beam transducer for prolonged use in elevated temperature environments. Through the use of a carbonl carbon composite backing layer, prolonged exposure to elevated temperature had minimal effect on transducer performance. The conductive nature of the carbon/carbon allowed for an innovative electrical coupling technique. A clamping mechanism combined with the use of an annealed gold quarter wave matching layer allowed for joint- free, dry coupling. This simple design allows for easy field assembly and eliminates temperature dependencies in the acoustic coupling. The transducer was tested initially at room temperature for reference data. Further tests after 100+ h of exposure to a 351 K environment showed little overall change in the transducer performance. The transducer showed consistent -6 dB bandwidths on the order of 54 to 67%, along with negligible change in centerline frequency. The insertion loss as a function of temperature showed an increase from approximately 6.8 to 8.5 dB over a temperature range from 298 to 358 K. Regression lines show bandwidth changes of -0.01% per 1 K and insertion loss changes of 0.03 dB per 1 K. These results show potential use for a transducer of this design at even higher temperatures.

AB - This paper describes the novel design of an ultrasonic normal beam transducer for prolonged use in elevated temperature environments. Through the use of a carbonl carbon composite backing layer, prolonged exposure to elevated temperature had minimal effect on transducer performance. The conductive nature of the carbon/carbon allowed for an innovative electrical coupling technique. A clamping mechanism combined with the use of an annealed gold quarter wave matching layer allowed for joint- free, dry coupling. This simple design allows for easy field assembly and eliminates temperature dependencies in the acoustic coupling. The transducer was tested initially at room temperature for reference data. Further tests after 100+ h of exposure to a 351 K environment showed little overall change in the transducer performance. The transducer showed consistent -6 dB bandwidths on the order of 54 to 67%, along with negligible change in centerline frequency. The insertion loss as a function of temperature showed an increase from approximately 6.8 to 8.5 dB over a temperature range from 298 to 358 K. Regression lines show bandwidth changes of -0.01% per 1 K and insertion loss changes of 0.03 dB per 1 K. These results show potential use for a transducer of this design at even higher temperatures.

UR - http://www.scopus.com/inward/record.url?scp=68649103981&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=68649103981&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:68649103981

VL - 67

SP - 149

EP - 153

JO - Materials Evaluation

JF - Materials Evaluation

SN - 0025-5327

ER -