TY - JOUR
T1 - Design, development, and multi-characterization of an integrated clinical transrectal ultrasound and photoacoustic device for human prostate imaging
AU - Agrawal, Sumit
AU - Johnstonbaugh, Kerrick
AU - Clark, Joseph Y.
AU - Raman, Jay D.
AU - Wang, Xueding
AU - Kothapalli, Sri Rajasekhar
N1 - Funding Information:
Funding: This project was partially funded by the NIH-NIBIB R00EB017729-05 (SRK) and Penn State Cancer Institute (SRK).
Publisher Copyright:
© 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
PY - 2020/8
Y1 - 2020/8
N2 - The standard diagnostic procedure for prostate cancer (PCa) is transrectal ultrasound (TRUS)-guided needle biopsy. However, due to the low sensitivity of TRUS to cancerous tissue in the prostate, small yet clinically significant tumors can be missed. Magnetic resonance imaging (MRI) with TRUS fusion biopsy has recently been introduced as a way to improve the identification of clinically significant PCa in men. However, the spatial errors in coregistering the preprocedural MRI with the real-time TRUS causes false negatives. A real-time and intraprocedural imaging modality that can sensitively detect PCa tumors and, more importantly, differentiate aggressive from nonaggressive tumors could largely improve the guidance of biopsy sampling to improve diagnostic accuracy and patient risk stratification. In this work, we seek to fill this long-standing gap in clinical diagnosis of PCa via the development of a dual-modality imaging device that integrates the emerging photoacoustic imaging (PAI) technique with the established TRUS for improved guidance of PCa needle biopsy. Unlike previously published studies on the integration of TRUS with PAI capabilities, this work introduces a novel approach for integrating a focused light delivery mechanism with a clinical-grade commercial TRUS probe, while assuring much-needed ease of operation in the transrectal space. We further present the clinical potential of our device by (i) performing rigorous characterization studies, (ii) examining the acoustic and optical safety parameters for human prostate imaging, and (iii) demonstrating the structural and functional imaging capabilities using deep-tissue-mimicking phantoms. Our TRUSPA experimental studies demonstrated a field-of-view in the range of 130 to 150 degrees and spatial resolutions in the range of 300 µm to 400 µm at a soft tissue imaging depth of 5 cm.
AB - The standard diagnostic procedure for prostate cancer (PCa) is transrectal ultrasound (TRUS)-guided needle biopsy. However, due to the low sensitivity of TRUS to cancerous tissue in the prostate, small yet clinically significant tumors can be missed. Magnetic resonance imaging (MRI) with TRUS fusion biopsy has recently been introduced as a way to improve the identification of clinically significant PCa in men. However, the spatial errors in coregistering the preprocedural MRI with the real-time TRUS causes false negatives. A real-time and intraprocedural imaging modality that can sensitively detect PCa tumors and, more importantly, differentiate aggressive from nonaggressive tumors could largely improve the guidance of biopsy sampling to improve diagnostic accuracy and patient risk stratification. In this work, we seek to fill this long-standing gap in clinical diagnosis of PCa via the development of a dual-modality imaging device that integrates the emerging photoacoustic imaging (PAI) technique with the established TRUS for improved guidance of PCa needle biopsy. Unlike previously published studies on the integration of TRUS with PAI capabilities, this work introduces a novel approach for integrating a focused light delivery mechanism with a clinical-grade commercial TRUS probe, while assuring much-needed ease of operation in the transrectal space. We further present the clinical potential of our device by (i) performing rigorous characterization studies, (ii) examining the acoustic and optical safety parameters for human prostate imaging, and (iii) demonstrating the structural and functional imaging capabilities using deep-tissue-mimicking phantoms. Our TRUSPA experimental studies demonstrated a field-of-view in the range of 130 to 150 degrees and spatial resolutions in the range of 300 µm to 400 µm at a soft tissue imaging depth of 5 cm.
UR - http://www.scopus.com/inward/record.url?scp=85090249936&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85090249936&partnerID=8YFLogxK
U2 - 10.3390/diagnostics10080566
DO - 10.3390/diagnostics10080566
M3 - Article
C2 - 32784534
AN - SCOPUS:85090249936
VL - 10
JO - Diagnostics
JF - Diagnostics
SN - 2075-4418
IS - 8
M1 - 566
ER -