Design of a mobile, homogeneous, and efficient electromagnet with a large field of view for neonatal low-field MRI

Steffen Lother, Steven J. Schiff, Thomas Neuberger, Peter M. Jakob, Florian Fidler

Research output: Contribution to journalArticle

5 Citations (Scopus)

Abstract

Objective: In this work, a prototype of an effective electromagnet with a field-of-view (FoV) of 140 mm for neonatal head imaging is presented. The efficient implementation succeeded by exploiting the use of steel plates as a housing system. We achieved a compromise between large sample volumes, high homogeneity, high B0 field, low power consumption, light weight, simple fabrication, and conserved mobility without the necessity of a dedicated water cooling system. Materials and methods: The entire magnetic resonance imaging (MRI) system (electromagnet, gradient system, transmit/receive coil, control system) is introduced and its unique features discussed. Furthermore, simulations using a numerical optimization algorithm for magnet and gradient system are presented. Results: Functionality and quality of this low-field scanner operating at 23 mT (generated with 500 W) is illustrated using spin-echo imaging (in-plane resolution 1.6 mm × 1.6 mm, slice thickness 5 mm, and signal-to-noise ratio (SNR) of 23 with a acquisition time of 29 min). B0 field-mapping measurements are presented to characterize the homogeneity of the magnet, and the B0 field limitations of 80 mT of the system are fully discussed. Conclusion: The cryogen-free system presented here demonstrates that this electromagnet with a ferromagnetic housing can be optimized for MRI with an enhanced and homogeneous magnetic field. It offers an alternative to prepolarized MRI designs in both readout field strength and power use. There are multiple indications for the clinical medical application of such low-field devices.

Original languageEnglish (US)
Pages (from-to)691-698
Number of pages8
JournalMagnetic Resonance Materials in Physics, Biology and Medicine
Volume29
Issue number4
DOIs
StatePublished - Aug 1 2016

Fingerprint

Magnets
Magnetic Resonance Imaging
Steel
Signal-To-Noise Ratio
Magnetic Fields
Head
Weights and Measures
Equipment and Supplies

All Science Journal Classification (ASJC) codes

  • Biophysics
  • Radiological and Ultrasound Technology
  • Radiology Nuclear Medicine and imaging

Cite this

@article{24ccb94621c946059c0ad867a2b662a4,
title = "Design of a mobile, homogeneous, and efficient electromagnet with a large field of view for neonatal low-field MRI",
abstract = "Objective: In this work, a prototype of an effective electromagnet with a field-of-view (FoV) of 140 mm for neonatal head imaging is presented. The efficient implementation succeeded by exploiting the use of steel plates as a housing system. We achieved a compromise between large sample volumes, high homogeneity, high B0 field, low power consumption, light weight, simple fabrication, and conserved mobility without the necessity of a dedicated water cooling system. Materials and methods: The entire magnetic resonance imaging (MRI) system (electromagnet, gradient system, transmit/receive coil, control system) is introduced and its unique features discussed. Furthermore, simulations using a numerical optimization algorithm for magnet and gradient system are presented. Results: Functionality and quality of this low-field scanner operating at 23 mT (generated with 500 W) is illustrated using spin-echo imaging (in-plane resolution 1.6 mm × 1.6 mm, slice thickness 5 mm, and signal-to-noise ratio (SNR) of 23 with a acquisition time of 29 min). B0 field-mapping measurements are presented to characterize the homogeneity of the magnet, and the B0 field limitations of 80 mT of the system are fully discussed. Conclusion: The cryogen-free system presented here demonstrates that this electromagnet with a ferromagnetic housing can be optimized for MRI with an enhanced and homogeneous magnetic field. It offers an alternative to prepolarized MRI designs in both readout field strength and power use. There are multiple indications for the clinical medical application of such low-field devices.",
author = "Steffen Lother and Schiff, {Steven J.} and Thomas Neuberger and Jakob, {Peter M.} and Florian Fidler",
year = "2016",
month = "8",
day = "1",
doi = "10.1007/s10334-016-0525-8",
language = "English (US)",
volume = "29",
pages = "691--698",
journal = "Magnetic Resonance Materials in Physics, Biology, and Medicine",
issn = "0968-5243",
publisher = "Springer Verlag",
number = "4",

}

Design of a mobile, homogeneous, and efficient electromagnet with a large field of view for neonatal low-field MRI. / Lother, Steffen; Schiff, Steven J.; Neuberger, Thomas; Jakob, Peter M.; Fidler, Florian.

In: Magnetic Resonance Materials in Physics, Biology and Medicine, Vol. 29, No. 4, 01.08.2016, p. 691-698.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Design of a mobile, homogeneous, and efficient electromagnet with a large field of view for neonatal low-field MRI

AU - Lother, Steffen

AU - Schiff, Steven J.

AU - Neuberger, Thomas

AU - Jakob, Peter M.

AU - Fidler, Florian

PY - 2016/8/1

Y1 - 2016/8/1

N2 - Objective: In this work, a prototype of an effective electromagnet with a field-of-view (FoV) of 140 mm for neonatal head imaging is presented. The efficient implementation succeeded by exploiting the use of steel plates as a housing system. We achieved a compromise between large sample volumes, high homogeneity, high B0 field, low power consumption, light weight, simple fabrication, and conserved mobility without the necessity of a dedicated water cooling system. Materials and methods: The entire magnetic resonance imaging (MRI) system (electromagnet, gradient system, transmit/receive coil, control system) is introduced and its unique features discussed. Furthermore, simulations using a numerical optimization algorithm for magnet and gradient system are presented. Results: Functionality and quality of this low-field scanner operating at 23 mT (generated with 500 W) is illustrated using spin-echo imaging (in-plane resolution 1.6 mm × 1.6 mm, slice thickness 5 mm, and signal-to-noise ratio (SNR) of 23 with a acquisition time of 29 min). B0 field-mapping measurements are presented to characterize the homogeneity of the magnet, and the B0 field limitations of 80 mT of the system are fully discussed. Conclusion: The cryogen-free system presented here demonstrates that this electromagnet with a ferromagnetic housing can be optimized for MRI with an enhanced and homogeneous magnetic field. It offers an alternative to prepolarized MRI designs in both readout field strength and power use. There are multiple indications for the clinical medical application of such low-field devices.

AB - Objective: In this work, a prototype of an effective electromagnet with a field-of-view (FoV) of 140 mm for neonatal head imaging is presented. The efficient implementation succeeded by exploiting the use of steel plates as a housing system. We achieved a compromise between large sample volumes, high homogeneity, high B0 field, low power consumption, light weight, simple fabrication, and conserved mobility without the necessity of a dedicated water cooling system. Materials and methods: The entire magnetic resonance imaging (MRI) system (electromagnet, gradient system, transmit/receive coil, control system) is introduced and its unique features discussed. Furthermore, simulations using a numerical optimization algorithm for magnet and gradient system are presented. Results: Functionality and quality of this low-field scanner operating at 23 mT (generated with 500 W) is illustrated using spin-echo imaging (in-plane resolution 1.6 mm × 1.6 mm, slice thickness 5 mm, and signal-to-noise ratio (SNR) of 23 with a acquisition time of 29 min). B0 field-mapping measurements are presented to characterize the homogeneity of the magnet, and the B0 field limitations of 80 mT of the system are fully discussed. Conclusion: The cryogen-free system presented here demonstrates that this electromagnet with a ferromagnetic housing can be optimized for MRI with an enhanced and homogeneous magnetic field. It offers an alternative to prepolarized MRI designs in both readout field strength and power use. There are multiple indications for the clinical medical application of such low-field devices.

UR - http://www.scopus.com/inward/record.url?scp=84957700468&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84957700468&partnerID=8YFLogxK

U2 - 10.1007/s10334-016-0525-8

DO - 10.1007/s10334-016-0525-8

M3 - Article

C2 - 26861046

AN - SCOPUS:84957700468

VL - 29

SP - 691

EP - 698

JO - Magnetic Resonance Materials in Physics, Biology, and Medicine

JF - Magnetic Resonance Materials in Physics, Biology, and Medicine

SN - 0968-5243

IS - 4

ER -