Does volume catheter parallel conductance vary during a cardiac cycle?

Edward Lankford, D. A. Kass, W. L. Maughan, A. A. Shoukas

Research output: Contribution to journalArticle

70 Citations (Scopus)

Abstract

Absolute left ventricular volume measurement by the conductance (volume) catheter requires subtraction of the conductance contribution from structures extrinsic to the cavity blood pool. Previously, this parallel conductance volume (V(p)) has been assumed constant throughout the cardiac cycle, and the technique described for its estimation in situ yields a single value. We present a new method for parallel conductance determination that yields multiple estimates during systole, enabling an assessment of V(p) variability [V(p)(t)]. For isolated blood-perfused ejecting canine left ventricles with empty (vented) right ventricles, V(p)(t) displayed virtually no variation throughout systole. For in situ hearts, despite the presence of other cardiac chambers, V(p)(t) also displayed little variation, with no statistically significant deviation from its mean value throughout systole. Volume signal simulations found the new technique to be less sensitive to signal noise and thus more robust than the one previously published. The isolated and in situ heart data indicate that for the left ventricle, the parallel conductance is relatively constant throughout normal ejection.

Original languageEnglish (US)
JournalAmerican Journal of Physiology - Heart and Circulatory Physiology
Volume258
Issue number6 27-6
StatePublished - Jan 1 1990

Fingerprint

Systole
Heart Ventricles
Catheters
Canidae

All Science Journal Classification (ASJC) codes

  • Physiology
  • Cardiology and Cardiovascular Medicine
  • Physiology (medical)

Cite this

@article{93067c7840fd4372923bfea3be80ac0d,
title = "Does volume catheter parallel conductance vary during a cardiac cycle?",
abstract = "Absolute left ventricular volume measurement by the conductance (volume) catheter requires subtraction of the conductance contribution from structures extrinsic to the cavity blood pool. Previously, this parallel conductance volume (V(p)) has been assumed constant throughout the cardiac cycle, and the technique described for its estimation in situ yields a single value. We present a new method for parallel conductance determination that yields multiple estimates during systole, enabling an assessment of V(p) variability [V(p)(t)]. For isolated blood-perfused ejecting canine left ventricles with empty (vented) right ventricles, V(p)(t) displayed virtually no variation throughout systole. For in situ hearts, despite the presence of other cardiac chambers, V(p)(t) also displayed little variation, with no statistically significant deviation from its mean value throughout systole. Volume signal simulations found the new technique to be less sensitive to signal noise and thus more robust than the one previously published. The isolated and in situ heart data indicate that for the left ventricle, the parallel conductance is relatively constant throughout normal ejection.",
author = "Edward Lankford and Kass, {D. A.} and Maughan, {W. L.} and Shoukas, {A. A.}",
year = "1990",
month = "1",
day = "1",
language = "English (US)",
volume = "258",
journal = "American Journal of Physiology",
issn = "0363-6135",
publisher = "American Physiological Society",
number = "6 27-6",

}

Does volume catheter parallel conductance vary during a cardiac cycle? / Lankford, Edward; Kass, D. A.; Maughan, W. L.; Shoukas, A. A.

In: American Journal of Physiology - Heart and Circulatory Physiology, Vol. 258, No. 6 27-6, 01.01.1990.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Does volume catheter parallel conductance vary during a cardiac cycle?

AU - Lankford, Edward

AU - Kass, D. A.

AU - Maughan, W. L.

AU - Shoukas, A. A.

PY - 1990/1/1

Y1 - 1990/1/1

N2 - Absolute left ventricular volume measurement by the conductance (volume) catheter requires subtraction of the conductance contribution from structures extrinsic to the cavity blood pool. Previously, this parallel conductance volume (V(p)) has been assumed constant throughout the cardiac cycle, and the technique described for its estimation in situ yields a single value. We present a new method for parallel conductance determination that yields multiple estimates during systole, enabling an assessment of V(p) variability [V(p)(t)]. For isolated blood-perfused ejecting canine left ventricles with empty (vented) right ventricles, V(p)(t) displayed virtually no variation throughout systole. For in situ hearts, despite the presence of other cardiac chambers, V(p)(t) also displayed little variation, with no statistically significant deviation from its mean value throughout systole. Volume signal simulations found the new technique to be less sensitive to signal noise and thus more robust than the one previously published. The isolated and in situ heart data indicate that for the left ventricle, the parallel conductance is relatively constant throughout normal ejection.

AB - Absolute left ventricular volume measurement by the conductance (volume) catheter requires subtraction of the conductance contribution from structures extrinsic to the cavity blood pool. Previously, this parallel conductance volume (V(p)) has been assumed constant throughout the cardiac cycle, and the technique described for its estimation in situ yields a single value. We present a new method for parallel conductance determination that yields multiple estimates during systole, enabling an assessment of V(p) variability [V(p)(t)]. For isolated blood-perfused ejecting canine left ventricles with empty (vented) right ventricles, V(p)(t) displayed virtually no variation throughout systole. For in situ hearts, despite the presence of other cardiac chambers, V(p)(t) also displayed little variation, with no statistically significant deviation from its mean value throughout systole. Volume signal simulations found the new technique to be less sensitive to signal noise and thus more robust than the one previously published. The isolated and in situ heart data indicate that for the left ventricle, the parallel conductance is relatively constant throughout normal ejection.

UR - http://www.scopus.com/inward/record.url?scp=0025277221&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0025277221&partnerID=8YFLogxK

M3 - Article

C2 - 2360681

AN - SCOPUS:0025277221

VL - 258

JO - American Journal of Physiology

JF - American Journal of Physiology

SN - 0363-6135

IS - 6 27-6

ER -