Duplex Imaging of the Renal Arteries with Contrast Enhancement

John Blebea, Robert Zickler, Nikolaos Volteas, Marsha Neumyer, Shahin Assadnia, Karla Anderson, Robert Atnip

Research output: Contribution to journalArticle

18 Citations (Scopus)

Abstract

Duplex ultrasound evaluation of the renal arteries is a technically challenging procedure. Its accuracy is significantly influenced by operator expertise and patient factors, such as overlying bowel gas and obesity. Intravenous microbubble contrast agents enhance vascular reflective acoustic signals and may improve ultrasound diagnostic accuracy. The clinical usefulness of such a contrast agent in the renal vasculature was examined prospectively. A total of 22 patients (16 males and 6 females) with mean age of 63 ±3 years with suspected abdominal vascular disease were studied prospectively. A complete color flow duplex imaging study of the renal vasculature was performed. This was then followed by an identical examination during which an ultrasound contrast agent (Definity™, DuPont Pharmaceutical) was infused intravenously at a rate of 2 to 4 mL/min. In addition to imaging of the vessels, the peak systolic velocity and Doppler waveforms of the aorta and renal arteries were examined. These results were independently compared to results with contrast angiography. A mean of 67 mL of contrast was used per patient. Of the total of 43 renal arteries examined, the accuracy for the detection of occlusions was 75% (3 of 4) for both standard and contrast-enhanced duplex ultrasound. The accuracy for the detection of hemodynamically significant stenosis was 50% (6 of 12) for standard and 75% (9 of 12) for contrast-enhanced duplex ultrasound. Visualization of normal or minimally diseased arteries was 94% (30 of 32) for standard and 97% (31 of 32) for contrast-enhanced ultrasound. Although overall accuracy was not enhanced by the infusion of ultrasound contrast, 5 of 7 arteries not visualized by color flow duplex were detected following the infusion of contrast agent, resulting in an additional 10% (5 of 48) of vessels visualized. Peak systolic velocities were increased by an average of 10% in normal or minimally diseased vessels and 12% in stenotic vessels following contrast administration but these differences were not statistically significant. Contrast-enhanced duplex imaging of the renal arteries is safe but not routinely required when performed by an experienced sonographer. However, it may increase visualization and accuracy in patients with stenoses or when the vessels are not initially visualized. Although increased velocities are seen when contrast agent is used, this does not appear to necessitate different Doppler criteria at this time.

Original languageEnglish (US)
Pages (from-to)429-436
Number of pages8
JournalVascular and Endovascular Surgery
Volume37
Issue number6
DOIs
StatePublished - Nov 1 2003

Fingerprint

Renal Artery
Contrast Media
Pathologic Constriction
Arteries
Color
Kidney
Microbubbles
Vascular Diseases
Acoustics
Blood Vessels
Aorta
Ultrasonography
Angiography
Obesity
Gases
Pharmaceutical Preparations

All Science Journal Classification (ASJC) codes

  • Surgery
  • Cardiology and Cardiovascular Medicine

Cite this

Blebea, J., Zickler, R., Volteas, N., Neumyer, M., Assadnia, S., Anderson, K., & Atnip, R. (2003). Duplex Imaging of the Renal Arteries with Contrast Enhancement. Vascular and Endovascular Surgery, 37(6), 429-436. https://doi.org/10.1177/153857440303700607
Blebea, John ; Zickler, Robert ; Volteas, Nikolaos ; Neumyer, Marsha ; Assadnia, Shahin ; Anderson, Karla ; Atnip, Robert. / Duplex Imaging of the Renal Arteries with Contrast Enhancement. In: Vascular and Endovascular Surgery. 2003 ; Vol. 37, No. 6. pp. 429-436.
@article{bd9b6d02e1a24af9ab0adc272a68b384,
title = "Duplex Imaging of the Renal Arteries with Contrast Enhancement",
abstract = "Duplex ultrasound evaluation of the renal arteries is a technically challenging procedure. Its accuracy is significantly influenced by operator expertise and patient factors, such as overlying bowel gas and obesity. Intravenous microbubble contrast agents enhance vascular reflective acoustic signals and may improve ultrasound diagnostic accuracy. The clinical usefulness of such a contrast agent in the renal vasculature was examined prospectively. A total of 22 patients (16 males and 6 females) with mean age of 63 ±3 years with suspected abdominal vascular disease were studied prospectively. A complete color flow duplex imaging study of the renal vasculature was performed. This was then followed by an identical examination during which an ultrasound contrast agent (Definity™, DuPont Pharmaceutical) was infused intravenously at a rate of 2 to 4 mL/min. In addition to imaging of the vessels, the peak systolic velocity and Doppler waveforms of the aorta and renal arteries were examined. These results were independently compared to results with contrast angiography. A mean of 67 mL of contrast was used per patient. Of the total of 43 renal arteries examined, the accuracy for the detection of occlusions was 75{\%} (3 of 4) for both standard and contrast-enhanced duplex ultrasound. The accuracy for the detection of hemodynamically significant stenosis was 50{\%} (6 of 12) for standard and 75{\%} (9 of 12) for contrast-enhanced duplex ultrasound. Visualization of normal or minimally diseased arteries was 94{\%} (30 of 32) for standard and 97{\%} (31 of 32) for contrast-enhanced ultrasound. Although overall accuracy was not enhanced by the infusion of ultrasound contrast, 5 of 7 arteries not visualized by color flow duplex were detected following the infusion of contrast agent, resulting in an additional 10{\%} (5 of 48) of vessels visualized. Peak systolic velocities were increased by an average of 10{\%} in normal or minimally diseased vessels and 12{\%} in stenotic vessels following contrast administration but these differences were not statistically significant. Contrast-enhanced duplex imaging of the renal arteries is safe but not routinely required when performed by an experienced sonographer. However, it may increase visualization and accuracy in patients with stenoses or when the vessels are not initially visualized. Although increased velocities are seen when contrast agent is used, this does not appear to necessitate different Doppler criteria at this time.",
author = "John Blebea and Robert Zickler and Nikolaos Volteas and Marsha Neumyer and Shahin Assadnia and Karla Anderson and Robert Atnip",
year = "2003",
month = "11",
day = "1",
doi = "10.1177/153857440303700607",
language = "English (US)",
volume = "37",
pages = "429--436",
journal = "Vascular and Endovascular Surgery",
issn = "1538-5744",
publisher = "SAGE Publications Inc.",
number = "6",

}

Blebea, J, Zickler, R, Volteas, N, Neumyer, M, Assadnia, S, Anderson, K & Atnip, R 2003, 'Duplex Imaging of the Renal Arteries with Contrast Enhancement', Vascular and Endovascular Surgery, vol. 37, no. 6, pp. 429-436. https://doi.org/10.1177/153857440303700607

Duplex Imaging of the Renal Arteries with Contrast Enhancement. / Blebea, John; Zickler, Robert; Volteas, Nikolaos; Neumyer, Marsha; Assadnia, Shahin; Anderson, Karla; Atnip, Robert.

In: Vascular and Endovascular Surgery, Vol. 37, No. 6, 01.11.2003, p. 429-436.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Duplex Imaging of the Renal Arteries with Contrast Enhancement

AU - Blebea, John

AU - Zickler, Robert

AU - Volteas, Nikolaos

AU - Neumyer, Marsha

AU - Assadnia, Shahin

AU - Anderson, Karla

AU - Atnip, Robert

PY - 2003/11/1

Y1 - 2003/11/1

N2 - Duplex ultrasound evaluation of the renal arteries is a technically challenging procedure. Its accuracy is significantly influenced by operator expertise and patient factors, such as overlying bowel gas and obesity. Intravenous microbubble contrast agents enhance vascular reflective acoustic signals and may improve ultrasound diagnostic accuracy. The clinical usefulness of such a contrast agent in the renal vasculature was examined prospectively. A total of 22 patients (16 males and 6 females) with mean age of 63 ±3 years with suspected abdominal vascular disease were studied prospectively. A complete color flow duplex imaging study of the renal vasculature was performed. This was then followed by an identical examination during which an ultrasound contrast agent (Definity™, DuPont Pharmaceutical) was infused intravenously at a rate of 2 to 4 mL/min. In addition to imaging of the vessels, the peak systolic velocity and Doppler waveforms of the aorta and renal arteries were examined. These results were independently compared to results with contrast angiography. A mean of 67 mL of contrast was used per patient. Of the total of 43 renal arteries examined, the accuracy for the detection of occlusions was 75% (3 of 4) for both standard and contrast-enhanced duplex ultrasound. The accuracy for the detection of hemodynamically significant stenosis was 50% (6 of 12) for standard and 75% (9 of 12) for contrast-enhanced duplex ultrasound. Visualization of normal or minimally diseased arteries was 94% (30 of 32) for standard and 97% (31 of 32) for contrast-enhanced ultrasound. Although overall accuracy was not enhanced by the infusion of ultrasound contrast, 5 of 7 arteries not visualized by color flow duplex were detected following the infusion of contrast agent, resulting in an additional 10% (5 of 48) of vessels visualized. Peak systolic velocities were increased by an average of 10% in normal or minimally diseased vessels and 12% in stenotic vessels following contrast administration but these differences were not statistically significant. Contrast-enhanced duplex imaging of the renal arteries is safe but not routinely required when performed by an experienced sonographer. However, it may increase visualization and accuracy in patients with stenoses or when the vessels are not initially visualized. Although increased velocities are seen when contrast agent is used, this does not appear to necessitate different Doppler criteria at this time.

AB - Duplex ultrasound evaluation of the renal arteries is a technically challenging procedure. Its accuracy is significantly influenced by operator expertise and patient factors, such as overlying bowel gas and obesity. Intravenous microbubble contrast agents enhance vascular reflective acoustic signals and may improve ultrasound diagnostic accuracy. The clinical usefulness of such a contrast agent in the renal vasculature was examined prospectively. A total of 22 patients (16 males and 6 females) with mean age of 63 ±3 years with suspected abdominal vascular disease were studied prospectively. A complete color flow duplex imaging study of the renal vasculature was performed. This was then followed by an identical examination during which an ultrasound contrast agent (Definity™, DuPont Pharmaceutical) was infused intravenously at a rate of 2 to 4 mL/min. In addition to imaging of the vessels, the peak systolic velocity and Doppler waveforms of the aorta and renal arteries were examined. These results were independently compared to results with contrast angiography. A mean of 67 mL of contrast was used per patient. Of the total of 43 renal arteries examined, the accuracy for the detection of occlusions was 75% (3 of 4) for both standard and contrast-enhanced duplex ultrasound. The accuracy for the detection of hemodynamically significant stenosis was 50% (6 of 12) for standard and 75% (9 of 12) for contrast-enhanced duplex ultrasound. Visualization of normal or minimally diseased arteries was 94% (30 of 32) for standard and 97% (31 of 32) for contrast-enhanced ultrasound. Although overall accuracy was not enhanced by the infusion of ultrasound contrast, 5 of 7 arteries not visualized by color flow duplex were detected following the infusion of contrast agent, resulting in an additional 10% (5 of 48) of vessels visualized. Peak systolic velocities were increased by an average of 10% in normal or minimally diseased vessels and 12% in stenotic vessels following contrast administration but these differences were not statistically significant. Contrast-enhanced duplex imaging of the renal arteries is safe but not routinely required when performed by an experienced sonographer. However, it may increase visualization and accuracy in patients with stenoses or when the vessels are not initially visualized. Although increased velocities are seen when contrast agent is used, this does not appear to necessitate different Doppler criteria at this time.

UR - http://www.scopus.com/inward/record.url?scp=0344442734&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0344442734&partnerID=8YFLogxK

U2 - 10.1177/153857440303700607

DO - 10.1177/153857440303700607

M3 - Article

VL - 37

SP - 429

EP - 436

JO - Vascular and Endovascular Surgery

JF - Vascular and Endovascular Surgery

SN - 1538-5744

IS - 6

ER -

Blebea J, Zickler R, Volteas N, Neumyer M, Assadnia S, Anderson K et al. Duplex Imaging of the Renal Arteries with Contrast Enhancement. Vascular and Endovascular Surgery. 2003 Nov 1;37(6):429-436. https://doi.org/10.1177/153857440303700607