T1 - Effect of direct-current countershocks on regional myocardial contractility and perfusion. Experimental studies
AU - Kerber, R. E.
AU - Martins, J. B.
AU - Gascho, J. A.
AU - Marcus, M. L.
AU - Grayzel, J.
N1 - Copyright:
Copyright 2017 Elsevier B.V., All rights reserved.
PY - 1981
Y1 - 1981
N2 - Very high energy electrical countershocks can cause morphologic damage to the myocardium. In this study we searched for functional correlates of these shock-induced morphologic changes. We used ultrasonic sonomicrometers to measure myocardial contractility and radiolabeled microspheres to assess perfusion. Acute and chronic experiments were conducted in 45 dogs, assessing the effect of both direct (epicardial) and transthoracic shocks on beating and fibrillating hearts. High-energy or rapidly repeated epicardial shocks caused subepicardial contraction abnormalities. This indicates that electrical current delivered to the myocardium in sufficiently high amounts and concentration can cause functional damage. Thus, in open-chest defibrillation during cardiac surgery, low energies (10-20 J) should be used initially and higher energies resorted to only if lower-energy shocks fail. However, single and multiple transthoracic shocks up to 460 J delivered energy caused no detectable contraction abnormalities. Myocardial perfusion did not fall after shocks. Thus, high-energy transthoracic shocks may have no deleterious effects on the contraction and perfusion of normal myocardium.
AB - Very high energy electrical countershocks can cause morphologic damage to the myocardium. In this study we searched for functional correlates of these shock-induced morphologic changes. We used ultrasonic sonomicrometers to measure myocardial contractility and radiolabeled microspheres to assess perfusion. Acute and chronic experiments were conducted in 45 dogs, assessing the effect of both direct (epicardial) and transthoracic shocks on beating and fibrillating hearts. High-energy or rapidly repeated epicardial shocks caused subepicardial contraction abnormalities. This indicates that electrical current delivered to the myocardium in sufficiently high amounts and concentration can cause functional damage. Thus, in open-chest defibrillation during cardiac surgery, low energies (10-20 J) should be used initially and higher energies resorted to only if lower-energy shocks fail. However, single and multiple transthoracic shocks up to 460 J delivered energy caused no detectable contraction abnormalities. Myocardial perfusion did not fall after shocks. Thus, high-energy transthoracic shocks may have no deleterious effects on the contraction and perfusion of normal myocardium.
UR - http://www.scopus.com/inward/record.url?scp=0019349711&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0019349711&partnerID=8YFLogxK
U2 - 10.1161/01.CIR.63.2.323
DO - 10.1161/01.CIR.63.2.323
M3 - Article
C2 - 7449055
AN - SCOPUS:0019349711
SN - 0042-1215
VL - 63
SP - 323
EP - 332
JO - [No source information available]
JF - [No source information available]
IS - 2
ER -