Effect of direct-current countershocks on regional myocardial contractility and perfusion. Experimental studies

R. E. Kerber, J. B. Martins, J. A. Gascho, M. L. Marcus, J. Grayzel

Research output: Contribution to journalArticle

76 Citations (Scopus)

Abstract

Very high energy electrical countershocks can cause morphologic damage to the myocardium. In this study we searched for functional correlates of these shock-induced morphologic changes. We used ultrasonic sonomicrometers to measure myocardial contractility and radiolabeled microspheres to assess perfusion. Acute and chronic experiments were conducted in 45 dogs, assessing the effect of both direct (epicardial) and transthoracic shocks on beating and fibrillating hearts. High-energy or rapidly repeated epicardial shocks caused subepicardial contraction abnormalities. This indicates that electrical current delivered to the myocardium in sufficiently high amounts and concentration can cause functional damage. Thus, in open-chest defibrillation during cardiac surgery, low energies (10-20 J) should be used initially and higher energies resorted to only if lower-energy shocks fail. However, single and multiple transthoracic shocks up to 460 J delivered energy caused no detectable contraction abnormalities. Myocardial perfusion did not fall after shocks. Thus, high-energy transthoracic shocks may have no deleterious effects on the contraction and perfusion of normal myocardium.

Original languageEnglish (US)
Pages (from-to)323-332
Number of pages10
JournalUnknown Journal
Volume63
Issue number2
DOIs
StatePublished - Jan 1 1981

Fingerprint

Shock
Perfusion
Myocardium
Microspheres
Ultrasonics
Thoracic Surgery
Thorax
Dogs

All Science Journal Classification (ASJC) codes

  • Cardiology and Cardiovascular Medicine
  • Physiology (medical)

Cite this

Kerber, R. E. ; Martins, J. B. ; Gascho, J. A. ; Marcus, M. L. ; Grayzel, J. / Effect of direct-current countershocks on regional myocardial contractility and perfusion. Experimental studies. In: Unknown Journal. 1981 ; Vol. 63, No. 2. pp. 323-332.
@article{b2b97e4e953145b5a81b015cdbe65534,
title = "Effect of direct-current countershocks on regional myocardial contractility and perfusion. Experimental studies",
abstract = "Very high energy electrical countershocks can cause morphologic damage to the myocardium. In this study we searched for functional correlates of these shock-induced morphologic changes. We used ultrasonic sonomicrometers to measure myocardial contractility and radiolabeled microspheres to assess perfusion. Acute and chronic experiments were conducted in 45 dogs, assessing the effect of both direct (epicardial) and transthoracic shocks on beating and fibrillating hearts. High-energy or rapidly repeated epicardial shocks caused subepicardial contraction abnormalities. This indicates that electrical current delivered to the myocardium in sufficiently high amounts and concentration can cause functional damage. Thus, in open-chest defibrillation during cardiac surgery, low energies (10-20 J) should be used initially and higher energies resorted to only if lower-energy shocks fail. However, single and multiple transthoracic shocks up to 460 J delivered energy caused no detectable contraction abnormalities. Myocardial perfusion did not fall after shocks. Thus, high-energy transthoracic shocks may have no deleterious effects on the contraction and perfusion of normal myocardium.",
author = "Kerber, {R. E.} and Martins, {J. B.} and Gascho, {J. A.} and Marcus, {M. L.} and J. Grayzel",
year = "1981",
month = "1",
day = "1",
doi = "10.1161/01.CIR.63.2.323",
language = "English (US)",
volume = "63",
pages = "323--332",
journal = "[No source information available]",
issn = "0042-1215",
number = "2",

}

Effect of direct-current countershocks on regional myocardial contractility and perfusion. Experimental studies. / Kerber, R. E.; Martins, J. B.; Gascho, J. A.; Marcus, M. L.; Grayzel, J.

In: Unknown Journal, Vol. 63, No. 2, 01.01.1981, p. 323-332.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Effect of direct-current countershocks on regional myocardial contractility and perfusion. Experimental studies

AU - Kerber, R. E.

AU - Martins, J. B.

AU - Gascho, J. A.

AU - Marcus, M. L.

AU - Grayzel, J.

PY - 1981/1/1

Y1 - 1981/1/1

N2 - Very high energy electrical countershocks can cause morphologic damage to the myocardium. In this study we searched for functional correlates of these shock-induced morphologic changes. We used ultrasonic sonomicrometers to measure myocardial contractility and radiolabeled microspheres to assess perfusion. Acute and chronic experiments were conducted in 45 dogs, assessing the effect of both direct (epicardial) and transthoracic shocks on beating and fibrillating hearts. High-energy or rapidly repeated epicardial shocks caused subepicardial contraction abnormalities. This indicates that electrical current delivered to the myocardium in sufficiently high amounts and concentration can cause functional damage. Thus, in open-chest defibrillation during cardiac surgery, low energies (10-20 J) should be used initially and higher energies resorted to only if lower-energy shocks fail. However, single and multiple transthoracic shocks up to 460 J delivered energy caused no detectable contraction abnormalities. Myocardial perfusion did not fall after shocks. Thus, high-energy transthoracic shocks may have no deleterious effects on the contraction and perfusion of normal myocardium.

AB - Very high energy electrical countershocks can cause morphologic damage to the myocardium. In this study we searched for functional correlates of these shock-induced morphologic changes. We used ultrasonic sonomicrometers to measure myocardial contractility and radiolabeled microspheres to assess perfusion. Acute and chronic experiments were conducted in 45 dogs, assessing the effect of both direct (epicardial) and transthoracic shocks on beating and fibrillating hearts. High-energy or rapidly repeated epicardial shocks caused subepicardial contraction abnormalities. This indicates that electrical current delivered to the myocardium in sufficiently high amounts and concentration can cause functional damage. Thus, in open-chest defibrillation during cardiac surgery, low energies (10-20 J) should be used initially and higher energies resorted to only if lower-energy shocks fail. However, single and multiple transthoracic shocks up to 460 J delivered energy caused no detectable contraction abnormalities. Myocardial perfusion did not fall after shocks. Thus, high-energy transthoracic shocks may have no deleterious effects on the contraction and perfusion of normal myocardium.

UR - http://www.scopus.com/inward/record.url?scp=0019349711&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0019349711&partnerID=8YFLogxK

U2 - 10.1161/01.CIR.63.2.323

DO - 10.1161/01.CIR.63.2.323

M3 - Article

C2 - 7449055

AN - SCOPUS:0019349711

VL - 63

SP - 323

EP - 332

JO - [No source information available]

JF - [No source information available]

SN - 0042-1215

IS - 2

ER -