Effect of iris registration on outcomes of LASIK for myopia with the VISX CustomVue platform

Majid Moshirfar, Michael Chen, Ladan Espandar, Jay J. Meyer, Dan Christensen, Steve M. Christiansen, Sonal B. Dave, Brent Bedke, Christopher Kurz

Research output: Contribution to journalArticle

16 Citations (Scopus)

Abstract

PURPOSE: To compare visual outcomes after LASIK using the VISX STAR S4 CustomVue, with and without Iris Registration technology. METHODS: In this retrospective study, LASIK was performed on 239 myopic eyes, with or without astigmatism, of 142 patients. Iris registration LASIK was performed on 121 eyes and non-iris registration LASIK was performed on 118 eyes. Primary outcome measures were uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), and manifest refraction. RESULTS: At 6 months, the mean values for UCVA (logMAR) were 0.00±0.09 in the iris registration group and -0.01±0.11 in the non-iris registration group (P=.587). Seventy-nine percent of eyes in the iris registration group had UCVA of 20/20 or better compared to 78% in the non-iris registration group (P=.518). Ninetytwo percent of eyes in the iris registration group and 90% in the non-iris registration group were within ±0.50 diopters (D) of emmetropia (P=.999). Mean postoperative absolute change in total root-mean-square higher order aberrations in the iris registration group and noniris registration group was 0.22 μm and 0.19 μm, respectively (P=.6). At 3 months, the mean magnitude of error of surgically induced astigmatism was -0.09 in the iris registration group and -0.04 in the non-iris registration group (P=.25). CONCLUSIONS: Wavefront-guided LASIK with the VISX STAR S4 CustomVue laser system, independent of iris registration status, is effective, safe, and predictable. Under well-controlled surgical conditions, this study did not fi nd any statistical signifi cance supporting the better achievement of visual acuity, astigmatism correction, or the lesser induction of higher order aberrations using iris registration in comparison to a non-iris registration system.

Original languageEnglish (US)
Pages (from-to)493-502
Number of pages10
JournalJournal of Refractive Surgery
Volume25
Issue number6
DOIs
StatePublished - Jun 1 2009

Fingerprint

Laser In Situ Keratomileusis
Myopia
Iris
Visual Acuity
Astigmatism
Emmetropia
Lasers
Retrospective Studies
Outcome Assessment (Health Care)
Technology

All Science Journal Classification (ASJC) codes

  • Surgery
  • Ophthalmology

Cite this

Moshirfar, M., Chen, M., Espandar, L., Meyer, J. J., Christensen, D., Christiansen, S. M., ... Kurz, C. (2009). Effect of iris registration on outcomes of LASIK for myopia with the VISX CustomVue platform. Journal of Refractive Surgery, 25(6), 493-502. https://doi.org/10.3928/1081597X-20090512-03
Moshirfar, Majid ; Chen, Michael ; Espandar, Ladan ; Meyer, Jay J. ; Christensen, Dan ; Christiansen, Steve M. ; Dave, Sonal B. ; Bedke, Brent ; Kurz, Christopher. / Effect of iris registration on outcomes of LASIK for myopia with the VISX CustomVue platform. In: Journal of Refractive Surgery. 2009 ; Vol. 25, No. 6. pp. 493-502.
@article{ce517fda4b0a490b92c06ba00575f78c,
title = "Effect of iris registration on outcomes of LASIK for myopia with the VISX CustomVue platform",
abstract = "PURPOSE: To compare visual outcomes after LASIK using the VISX STAR S4 CustomVue, with and without Iris Registration technology. METHODS: In this retrospective study, LASIK was performed on 239 myopic eyes, with or without astigmatism, of 142 patients. Iris registration LASIK was performed on 121 eyes and non-iris registration LASIK was performed on 118 eyes. Primary outcome measures were uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), and manifest refraction. RESULTS: At 6 months, the mean values for UCVA (logMAR) were 0.00±0.09 in the iris registration group and -0.01±0.11 in the non-iris registration group (P=.587). Seventy-nine percent of eyes in the iris registration group had UCVA of 20/20 or better compared to 78{\%} in the non-iris registration group (P=.518). Ninetytwo percent of eyes in the iris registration group and 90{\%} in the non-iris registration group were within ±0.50 diopters (D) of emmetropia (P=.999). Mean postoperative absolute change in total root-mean-square higher order aberrations in the iris registration group and noniris registration group was 0.22 μm and 0.19 μm, respectively (P=.6). At 3 months, the mean magnitude of error of surgically induced astigmatism was -0.09 in the iris registration group and -0.04 in the non-iris registration group (P=.25). CONCLUSIONS: Wavefront-guided LASIK with the VISX STAR S4 CustomVue laser system, independent of iris registration status, is effective, safe, and predictable. Under well-controlled surgical conditions, this study did not fi nd any statistical signifi cance supporting the better achievement of visual acuity, astigmatism correction, or the lesser induction of higher order aberrations using iris registration in comparison to a non-iris registration system.",
author = "Majid Moshirfar and Michael Chen and Ladan Espandar and Meyer, {Jay J.} and Dan Christensen and Christiansen, {Steve M.} and Dave, {Sonal B.} and Brent Bedke and Christopher Kurz",
year = "2009",
month = "6",
day = "1",
doi = "10.3928/1081597X-20090512-03",
language = "English (US)",
volume = "25",
pages = "493--502",
journal = "Journal of Refractive Surgery",
issn = "0883-0444",
publisher = "Slack Incorporated",
number = "6",

}

Moshirfar, M, Chen, M, Espandar, L, Meyer, JJ, Christensen, D, Christiansen, SM, Dave, SB, Bedke, B & Kurz, C 2009, 'Effect of iris registration on outcomes of LASIK for myopia with the VISX CustomVue platform', Journal of Refractive Surgery, vol. 25, no. 6, pp. 493-502. https://doi.org/10.3928/1081597X-20090512-03

Effect of iris registration on outcomes of LASIK for myopia with the VISX CustomVue platform. / Moshirfar, Majid; Chen, Michael; Espandar, Ladan; Meyer, Jay J.; Christensen, Dan; Christiansen, Steve M.; Dave, Sonal B.; Bedke, Brent; Kurz, Christopher.

In: Journal of Refractive Surgery, Vol. 25, No. 6, 01.06.2009, p. 493-502.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Effect of iris registration on outcomes of LASIK for myopia with the VISX CustomVue platform

AU - Moshirfar, Majid

AU - Chen, Michael

AU - Espandar, Ladan

AU - Meyer, Jay J.

AU - Christensen, Dan

AU - Christiansen, Steve M.

AU - Dave, Sonal B.

AU - Bedke, Brent

AU - Kurz, Christopher

PY - 2009/6/1

Y1 - 2009/6/1

N2 - PURPOSE: To compare visual outcomes after LASIK using the VISX STAR S4 CustomVue, with and without Iris Registration technology. METHODS: In this retrospective study, LASIK was performed on 239 myopic eyes, with or without astigmatism, of 142 patients. Iris registration LASIK was performed on 121 eyes and non-iris registration LASIK was performed on 118 eyes. Primary outcome measures were uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), and manifest refraction. RESULTS: At 6 months, the mean values for UCVA (logMAR) were 0.00±0.09 in the iris registration group and -0.01±0.11 in the non-iris registration group (P=.587). Seventy-nine percent of eyes in the iris registration group had UCVA of 20/20 or better compared to 78% in the non-iris registration group (P=.518). Ninetytwo percent of eyes in the iris registration group and 90% in the non-iris registration group were within ±0.50 diopters (D) of emmetropia (P=.999). Mean postoperative absolute change in total root-mean-square higher order aberrations in the iris registration group and noniris registration group was 0.22 μm and 0.19 μm, respectively (P=.6). At 3 months, the mean magnitude of error of surgically induced astigmatism was -0.09 in the iris registration group and -0.04 in the non-iris registration group (P=.25). CONCLUSIONS: Wavefront-guided LASIK with the VISX STAR S4 CustomVue laser system, independent of iris registration status, is effective, safe, and predictable. Under well-controlled surgical conditions, this study did not fi nd any statistical signifi cance supporting the better achievement of visual acuity, astigmatism correction, or the lesser induction of higher order aberrations using iris registration in comparison to a non-iris registration system.

AB - PURPOSE: To compare visual outcomes after LASIK using the VISX STAR S4 CustomVue, with and without Iris Registration technology. METHODS: In this retrospective study, LASIK was performed on 239 myopic eyes, with or without astigmatism, of 142 patients. Iris registration LASIK was performed on 121 eyes and non-iris registration LASIK was performed on 118 eyes. Primary outcome measures were uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), and manifest refraction. RESULTS: At 6 months, the mean values for UCVA (logMAR) were 0.00±0.09 in the iris registration group and -0.01±0.11 in the non-iris registration group (P=.587). Seventy-nine percent of eyes in the iris registration group had UCVA of 20/20 or better compared to 78% in the non-iris registration group (P=.518). Ninetytwo percent of eyes in the iris registration group and 90% in the non-iris registration group were within ±0.50 diopters (D) of emmetropia (P=.999). Mean postoperative absolute change in total root-mean-square higher order aberrations in the iris registration group and noniris registration group was 0.22 μm and 0.19 μm, respectively (P=.6). At 3 months, the mean magnitude of error of surgically induced astigmatism was -0.09 in the iris registration group and -0.04 in the non-iris registration group (P=.25). CONCLUSIONS: Wavefront-guided LASIK with the VISX STAR S4 CustomVue laser system, independent of iris registration status, is effective, safe, and predictable. Under well-controlled surgical conditions, this study did not fi nd any statistical signifi cance supporting the better achievement of visual acuity, astigmatism correction, or the lesser induction of higher order aberrations using iris registration in comparison to a non-iris registration system.

UR - http://www.scopus.com/inward/record.url?scp=67649371709&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=67649371709&partnerID=8YFLogxK

U2 - 10.3928/1081597X-20090512-03

DO - 10.3928/1081597X-20090512-03

M3 - Article

VL - 25

SP - 493

EP - 502

JO - Journal of Refractive Surgery

JF - Journal of Refractive Surgery

SN - 0883-0444

IS - 6

ER -