Effective ventricular unloading by left ventricular assist device varies with stage of heart failure

Cardiac simulator study

Choon-Sik Jhun, John David Reibson, Joshua Cysyk

Research output: Contribution to journalArticle

11 Citations (Scopus)

Abstract

Although the use of left ventricular assist devices (LVADs) as a bridge-to-recovery (BTR) has shown promise, clinical success has been limited due to the lack of understanding the timing of implantation, acute/chronic device setting, and explantation. This study investigated the effective ventricular unloading at different heart conditions by using a mock circulatory system (MCS) to provide a tool for pump parameter adjustments. We tested the hypothesis that effective unloading by LVAD at a given speed varies with the stage of heart failure. By using a MCS, systematic depression of cardiac performance was obtained. Five different stages of heart failure from control were achieved by adjusting the pneumatic systolic/diastolic pressure, filling pressure, and systemic resistance. The Heart Mate II® (Thoratec Corp., Pleasanton, CA) was used for volumetric and pressure unloading at different heart conditions over a given LVAD speed. The effective unloading at a given LVAD speed was greater in more depressed heart condition. The rate of unloading over LVAD speed was also greater in more depressed heart condition. In conclusion, to get continuous and optimal cardiac recovery, timely increase in LVAD speed over a period of support is needed while avoiding the akinesis of aortic valve.

Original languageEnglish (US)
Pages (from-to)407-413
Number of pages7
JournalASAIO Journal
Volume57
Issue number5
DOIs
StatePublished - Sep 1 2011

Fingerprint

Left ventricular assist devices
Heart-Assist Devices
Unloading
Heart Failure
Simulators
Cardiovascular System
Blood Pressure
Pressure
Recovery
Aortic Valve
Pneumatics
Equipment and Supplies
Pumps

All Science Journal Classification (ASJC) codes

  • Biophysics
  • Biomaterials
  • Bioengineering
  • Biomedical Engineering
  • Medicine(all)

Cite this

@article{3eca09fd9414448baedcdfc1eb2dea1d,
title = "Effective ventricular unloading by left ventricular assist device varies with stage of heart failure: Cardiac simulator study",
abstract = "Although the use of left ventricular assist devices (LVADs) as a bridge-to-recovery (BTR) has shown promise, clinical success has been limited due to the lack of understanding the timing of implantation, acute/chronic device setting, and explantation. This study investigated the effective ventricular unloading at different heart conditions by using a mock circulatory system (MCS) to provide a tool for pump parameter adjustments. We tested the hypothesis that effective unloading by LVAD at a given speed varies with the stage of heart failure. By using a MCS, systematic depression of cardiac performance was obtained. Five different stages of heart failure from control were achieved by adjusting the pneumatic systolic/diastolic pressure, filling pressure, and systemic resistance. The Heart Mate II{\circledR} (Thoratec Corp., Pleasanton, CA) was used for volumetric and pressure unloading at different heart conditions over a given LVAD speed. The effective unloading at a given LVAD speed was greater in more depressed heart condition. The rate of unloading over LVAD speed was also greater in more depressed heart condition. In conclusion, to get continuous and optimal cardiac recovery, timely increase in LVAD speed over a period of support is needed while avoiding the akinesis of aortic valve.",
author = "Choon-Sik Jhun and Reibson, {John David} and Joshua Cysyk",
year = "2011",
month = "9",
day = "1",
doi = "10.1097/MAT.0b013e318229ca8d",
language = "English (US)",
volume = "57",
pages = "407--413",
journal = "ASAIO Journal",
issn = "1058-2916",
publisher = "Lippincott Williams and Wilkins",
number = "5",

}

Effective ventricular unloading by left ventricular assist device varies with stage of heart failure : Cardiac simulator study. / Jhun, Choon-Sik; Reibson, John David; Cysyk, Joshua.

In: ASAIO Journal, Vol. 57, No. 5, 01.09.2011, p. 407-413.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Effective ventricular unloading by left ventricular assist device varies with stage of heart failure

T2 - Cardiac simulator study

AU - Jhun, Choon-Sik

AU - Reibson, John David

AU - Cysyk, Joshua

PY - 2011/9/1

Y1 - 2011/9/1

N2 - Although the use of left ventricular assist devices (LVADs) as a bridge-to-recovery (BTR) has shown promise, clinical success has been limited due to the lack of understanding the timing of implantation, acute/chronic device setting, and explantation. This study investigated the effective ventricular unloading at different heart conditions by using a mock circulatory system (MCS) to provide a tool for pump parameter adjustments. We tested the hypothesis that effective unloading by LVAD at a given speed varies with the stage of heart failure. By using a MCS, systematic depression of cardiac performance was obtained. Five different stages of heart failure from control were achieved by adjusting the pneumatic systolic/diastolic pressure, filling pressure, and systemic resistance. The Heart Mate II® (Thoratec Corp., Pleasanton, CA) was used for volumetric and pressure unloading at different heart conditions over a given LVAD speed. The effective unloading at a given LVAD speed was greater in more depressed heart condition. The rate of unloading over LVAD speed was also greater in more depressed heart condition. In conclusion, to get continuous and optimal cardiac recovery, timely increase in LVAD speed over a period of support is needed while avoiding the akinesis of aortic valve.

AB - Although the use of left ventricular assist devices (LVADs) as a bridge-to-recovery (BTR) has shown promise, clinical success has been limited due to the lack of understanding the timing of implantation, acute/chronic device setting, and explantation. This study investigated the effective ventricular unloading at different heart conditions by using a mock circulatory system (MCS) to provide a tool for pump parameter adjustments. We tested the hypothesis that effective unloading by LVAD at a given speed varies with the stage of heart failure. By using a MCS, systematic depression of cardiac performance was obtained. Five different stages of heart failure from control were achieved by adjusting the pneumatic systolic/diastolic pressure, filling pressure, and systemic resistance. The Heart Mate II® (Thoratec Corp., Pleasanton, CA) was used for volumetric and pressure unloading at different heart conditions over a given LVAD speed. The effective unloading at a given LVAD speed was greater in more depressed heart condition. The rate of unloading over LVAD speed was also greater in more depressed heart condition. In conclusion, to get continuous and optimal cardiac recovery, timely increase in LVAD speed over a period of support is needed while avoiding the akinesis of aortic valve.

UR - http://www.scopus.com/inward/record.url?scp=80052452335&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=80052452335&partnerID=8YFLogxK

U2 - 10.1097/MAT.0b013e318229ca8d

DO - 10.1097/MAT.0b013e318229ca8d

M3 - Article

VL - 57

SP - 407

EP - 413

JO - ASAIO Journal

JF - ASAIO Journal

SN - 1058-2916

IS - 5

ER -