Electrochemical study of multi-electrode microbial fuel cells under fed-batch and continuous flow conditions

Lijiao Ren, Yongtae Ahn, Huijie Hou, Fang Zhang, Bruce Ernest Logan

Research output: Contribution to journalArticle

24 Citations (Scopus)

Abstract

Power production of four hydraulically connected microbial fuel cells (MFCs) was compared with the reactors operated using individual electrical circuits (individual), and when four anodes were wired together and connected to four cathodes all wired together (combined), in fed-batch or continuous flow conditions. Power production under these different conditions could not be made based on a single resistance, but instead required polarization tests to assess individual performance relative to the combined MFCs. Based on the power curves, power produced by the combined MFCs (2.12 ± 0.03 mW, 200 ω) was the same as the summed power (2.13 mW, 50 ω) produced by the four individual reactors in fed-batch mode. With continuous flow through the four MFCs, the maximum power (0.59 ± 0.01 mW) produced by the combined MFCs was slightly lower than the summed maximum power of the four individual reactors (0.68 ± 0.02 mW). There was a small parasitic current flow from adjacent anodes and cathodes, but overall performance was relatively unaffected. These findings demonstrate that optimal power production by reactors hydraulically and electrically connected can be predicted from performance by individual reactors.

Original languageEnglish (US)
Pages (from-to)454-460
Number of pages7
JournalJournal of Power Sources
Volume257
DOIs
StatePublished - Jul 1 2014

Fingerprint

Microbial fuel cells
fuel cells
reactors
Electrodes
electrodes
Anodes
Cathodes
anodes
cathodes
Polarization
Networks (circuits)
curves
polarization

All Science Journal Classification (ASJC) codes

  • Renewable Energy, Sustainability and the Environment
  • Energy Engineering and Power Technology
  • Physical and Theoretical Chemistry
  • Electrical and Electronic Engineering

Cite this

@article{90ab39a5e99b4140ad69fee8e484b44b,
title = "Electrochemical study of multi-electrode microbial fuel cells under fed-batch and continuous flow conditions",
abstract = "Power production of four hydraulically connected microbial fuel cells (MFCs) was compared with the reactors operated using individual electrical circuits (individual), and when four anodes were wired together and connected to four cathodes all wired together (combined), in fed-batch or continuous flow conditions. Power production under these different conditions could not be made based on a single resistance, but instead required polarization tests to assess individual performance relative to the combined MFCs. Based on the power curves, power produced by the combined MFCs (2.12 ± 0.03 mW, 200 ω) was the same as the summed power (2.13 mW, 50 ω) produced by the four individual reactors in fed-batch mode. With continuous flow through the four MFCs, the maximum power (0.59 ± 0.01 mW) produced by the combined MFCs was slightly lower than the summed maximum power of the four individual reactors (0.68 ± 0.02 mW). There was a small parasitic current flow from adjacent anodes and cathodes, but overall performance was relatively unaffected. These findings demonstrate that optimal power production by reactors hydraulically and electrically connected can be predicted from performance by individual reactors.",
author = "Lijiao Ren and Yongtae Ahn and Huijie Hou and Fang Zhang and Logan, {Bruce Ernest}",
year = "2014",
month = "7",
day = "1",
doi = "10.1016/j.jpowsour.2013.11.085",
language = "English (US)",
volume = "257",
pages = "454--460",
journal = "Journal of Power Sources",
issn = "0378-7753",
publisher = "Elsevier",

}

Electrochemical study of multi-electrode microbial fuel cells under fed-batch and continuous flow conditions. / Ren, Lijiao; Ahn, Yongtae; Hou, Huijie; Zhang, Fang; Logan, Bruce Ernest.

In: Journal of Power Sources, Vol. 257, 01.07.2014, p. 454-460.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Electrochemical study of multi-electrode microbial fuel cells under fed-batch and continuous flow conditions

AU - Ren, Lijiao

AU - Ahn, Yongtae

AU - Hou, Huijie

AU - Zhang, Fang

AU - Logan, Bruce Ernest

PY - 2014/7/1

Y1 - 2014/7/1

N2 - Power production of four hydraulically connected microbial fuel cells (MFCs) was compared with the reactors operated using individual electrical circuits (individual), and when four anodes were wired together and connected to four cathodes all wired together (combined), in fed-batch or continuous flow conditions. Power production under these different conditions could not be made based on a single resistance, but instead required polarization tests to assess individual performance relative to the combined MFCs. Based on the power curves, power produced by the combined MFCs (2.12 ± 0.03 mW, 200 ω) was the same as the summed power (2.13 mW, 50 ω) produced by the four individual reactors in fed-batch mode. With continuous flow through the four MFCs, the maximum power (0.59 ± 0.01 mW) produced by the combined MFCs was slightly lower than the summed maximum power of the four individual reactors (0.68 ± 0.02 mW). There was a small parasitic current flow from adjacent anodes and cathodes, but overall performance was relatively unaffected. These findings demonstrate that optimal power production by reactors hydraulically and electrically connected can be predicted from performance by individual reactors.

AB - Power production of four hydraulically connected microbial fuel cells (MFCs) was compared with the reactors operated using individual electrical circuits (individual), and when four anodes were wired together and connected to four cathodes all wired together (combined), in fed-batch or continuous flow conditions. Power production under these different conditions could not be made based on a single resistance, but instead required polarization tests to assess individual performance relative to the combined MFCs. Based on the power curves, power produced by the combined MFCs (2.12 ± 0.03 mW, 200 ω) was the same as the summed power (2.13 mW, 50 ω) produced by the four individual reactors in fed-batch mode. With continuous flow through the four MFCs, the maximum power (0.59 ± 0.01 mW) produced by the combined MFCs was slightly lower than the summed maximum power of the four individual reactors (0.68 ± 0.02 mW). There was a small parasitic current flow from adjacent anodes and cathodes, but overall performance was relatively unaffected. These findings demonstrate that optimal power production by reactors hydraulically and electrically connected can be predicted from performance by individual reactors.

UR - http://www.scopus.com/inward/record.url?scp=84897974564&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84897974564&partnerID=8YFLogxK

U2 - 10.1016/j.jpowsour.2013.11.085

DO - 10.1016/j.jpowsour.2013.11.085

M3 - Article

AN - SCOPUS:84897974564

VL - 257

SP - 454

EP - 460

JO - Journal of Power Sources

JF - Journal of Power Sources

SN - 0378-7753