Engineering tubulin: Microtubule functionalization approaches for nanoscale device applications

Jennelle L. Malcos, William O. Hancock

Research output: Contribution to journalReview article

20 Citations (Scopus)

Abstract

With the emergences of engineered devices at microscale and nanoscale dimensions, there is a growing need for controlled actuation and transport at these length scales. The kinesin-microtubule system provides a highly evolved biological transport system well suited for these tasks. Accordingly, there is an ongoing effort to create hybrid nanodevices that integrate biological components with engineered materials for applications such as biological separations, nanoscale assembly, and sensing. Adopting microtubules for these applications generally requires covalent attachment of biotin, fluorophores, or other biomolecules to tubulin enable surface or cargo attachment, or visualization. This review summarizes different strategies for functionalizing microtubules for application-focused as well as basic biological research. These functionalization strategies must maintain the integrity of microtubule proteins so that they do not depolymerize and can be transported by kinesin motors, while adding utility such as the ability to reversibly bind cargo. The relevant biochemical and electrical properties of microtubules are discussed, as well as strategies for microtubule stabilization and long-term storage. Next, attachment strategies, such as antibodies and DNA hybridization that have proven useful to date, are discussed in the context of ongoing hybrid nanodevice research. The review concludes with a discussion of less explored opportunities, such as harnessing the utility of tubulin posttranslational modifications and the use of recombinant tubulin that may enable future progress in nanodevice development.

Original languageEnglish (US)
Pages (from-to)1-10
Number of pages10
JournalApplied Microbiology and Biotechnology
Volume90
Issue number1
DOIs
StatePublished - Apr 1 2011

Fingerprint

Tubulin
Microtubules
Equipment and Supplies
Kinesin
Biological Transport
Microtubule Proteins
Post Translational Protein Processing
Biotin
Research
Antibodies
DNA

All Science Journal Classification (ASJC) codes

  • Biotechnology
  • Applied Microbiology and Biotechnology

Cite this

@article{36e218ba460543cdaf209657de0f6506,
title = "Engineering tubulin: Microtubule functionalization approaches for nanoscale device applications",
abstract = "With the emergences of engineered devices at microscale and nanoscale dimensions, there is a growing need for controlled actuation and transport at these length scales. The kinesin-microtubule system provides a highly evolved biological transport system well suited for these tasks. Accordingly, there is an ongoing effort to create hybrid nanodevices that integrate biological components with engineered materials for applications such as biological separations, nanoscale assembly, and sensing. Adopting microtubules for these applications generally requires covalent attachment of biotin, fluorophores, or other biomolecules to tubulin enable surface or cargo attachment, or visualization. This review summarizes different strategies for functionalizing microtubules for application-focused as well as basic biological research. These functionalization strategies must maintain the integrity of microtubule proteins so that they do not depolymerize and can be transported by kinesin motors, while adding utility such as the ability to reversibly bind cargo. The relevant biochemical and electrical properties of microtubules are discussed, as well as strategies for microtubule stabilization and long-term storage. Next, attachment strategies, such as antibodies and DNA hybridization that have proven useful to date, are discussed in the context of ongoing hybrid nanodevice research. The review concludes with a discussion of less explored opportunities, such as harnessing the utility of tubulin posttranslational modifications and the use of recombinant tubulin that may enable future progress in nanodevice development.",
author = "Malcos, {Jennelle L.} and Hancock, {William O.}",
year = "2011",
month = "4",
day = "1",
doi = "10.1007/s00253-011-3140-7",
language = "English (US)",
volume = "90",
pages = "1--10",
journal = "Applied Microbiology and Biotechnology",
issn = "0175-7598",
publisher = "Springer Verlag",
number = "1",

}

Engineering tubulin : Microtubule functionalization approaches for nanoscale device applications. / Malcos, Jennelle L.; Hancock, William O.

In: Applied Microbiology and Biotechnology, Vol. 90, No. 1, 01.04.2011, p. 1-10.

Research output: Contribution to journalReview article

TY - JOUR

T1 - Engineering tubulin

T2 - Microtubule functionalization approaches for nanoscale device applications

AU - Malcos, Jennelle L.

AU - Hancock, William O.

PY - 2011/4/1

Y1 - 2011/4/1

N2 - With the emergences of engineered devices at microscale and nanoscale dimensions, there is a growing need for controlled actuation and transport at these length scales. The kinesin-microtubule system provides a highly evolved biological transport system well suited for these tasks. Accordingly, there is an ongoing effort to create hybrid nanodevices that integrate biological components with engineered materials for applications such as biological separations, nanoscale assembly, and sensing. Adopting microtubules for these applications generally requires covalent attachment of biotin, fluorophores, or other biomolecules to tubulin enable surface or cargo attachment, or visualization. This review summarizes different strategies for functionalizing microtubules for application-focused as well as basic biological research. These functionalization strategies must maintain the integrity of microtubule proteins so that they do not depolymerize and can be transported by kinesin motors, while adding utility such as the ability to reversibly bind cargo. The relevant biochemical and electrical properties of microtubules are discussed, as well as strategies for microtubule stabilization and long-term storage. Next, attachment strategies, such as antibodies and DNA hybridization that have proven useful to date, are discussed in the context of ongoing hybrid nanodevice research. The review concludes with a discussion of less explored opportunities, such as harnessing the utility of tubulin posttranslational modifications and the use of recombinant tubulin that may enable future progress in nanodevice development.

AB - With the emergences of engineered devices at microscale and nanoscale dimensions, there is a growing need for controlled actuation and transport at these length scales. The kinesin-microtubule system provides a highly evolved biological transport system well suited for these tasks. Accordingly, there is an ongoing effort to create hybrid nanodevices that integrate biological components with engineered materials for applications such as biological separations, nanoscale assembly, and sensing. Adopting microtubules for these applications generally requires covalent attachment of biotin, fluorophores, or other biomolecules to tubulin enable surface or cargo attachment, or visualization. This review summarizes different strategies for functionalizing microtubules for application-focused as well as basic biological research. These functionalization strategies must maintain the integrity of microtubule proteins so that they do not depolymerize and can be transported by kinesin motors, while adding utility such as the ability to reversibly bind cargo. The relevant biochemical and electrical properties of microtubules are discussed, as well as strategies for microtubule stabilization and long-term storage. Next, attachment strategies, such as antibodies and DNA hybridization that have proven useful to date, are discussed in the context of ongoing hybrid nanodevice research. The review concludes with a discussion of less explored opportunities, such as harnessing the utility of tubulin posttranslational modifications and the use of recombinant tubulin that may enable future progress in nanodevice development.

UR - http://www.scopus.com/inward/record.url?scp=79851508601&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79851508601&partnerID=8YFLogxK

U2 - 10.1007/s00253-011-3140-7

DO - 10.1007/s00253-011-3140-7

M3 - Review article

C2 - 21327409

AN - SCOPUS:79851508601

VL - 90

SP - 1

EP - 10

JO - Applied Microbiology and Biotechnology

JF - Applied Microbiology and Biotechnology

SN - 0175-7598

IS - 1

ER -