Evaluation of a hindered-settling column for size/density separations

M. L. Young, M. S. Klima

Research output: Contribution to journalArticle

6 Citations (Scopus)

Abstract

Hindered-settling columns are used throughout the minerals industry for both size and density separations. In this study, the performance of a continuous laboratory-scale hindered-settling column was evaluated for various particle systems. The test variables included solids composition, water rate and column height. Column performance was evaluated using partition curves and corresponding performance parameters.

Original languageEnglish (US)
Pages (from-to)194-197
Number of pages4
JournalMinerals and Metallurgical Processing
Volume17
Issue number3
StatePublished - Dec 1 2000

Fingerprint

Mineral industry
Water
Chemical analysis
minerals industry
evaluation
water

All Science Journal Classification (ASJC) codes

  • Control and Systems Engineering
  • Chemistry(all)
  • Geotechnical Engineering and Engineering Geology
  • Mechanical Engineering
  • Metals and Alloys
  • Materials Chemistry

Cite this

@article{97b17476fa8649d18cc350102c9295f0,
title = "Evaluation of a hindered-settling column for size/density separations",
abstract = "Hindered-settling columns are used throughout the minerals industry for both size and density separations. In this study, the performance of a continuous laboratory-scale hindered-settling column was evaluated for various particle systems. The test variables included solids composition, water rate and column height. Column performance was evaluated using partition curves and corresponding performance parameters.",
author = "Young, {M. L.} and Klima, {M. S.}",
year = "2000",
month = "12",
day = "1",
language = "English (US)",
volume = "17",
pages = "194--197",
journal = "Mining, Metallurgy and Exploration",
issn = "2524-3462",
publisher = "Society for Mining, Metallurgy and Exploration",
number = "3",

}

Evaluation of a hindered-settling column for size/density separations. / Young, M. L.; Klima, M. S.

In: Minerals and Metallurgical Processing, Vol. 17, No. 3, 01.12.2000, p. 194-197.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Evaluation of a hindered-settling column for size/density separations

AU - Young, M. L.

AU - Klima, M. S.

PY - 2000/12/1

Y1 - 2000/12/1

N2 - Hindered-settling columns are used throughout the minerals industry for both size and density separations. In this study, the performance of a continuous laboratory-scale hindered-settling column was evaluated for various particle systems. The test variables included solids composition, water rate and column height. Column performance was evaluated using partition curves and corresponding performance parameters.

AB - Hindered-settling columns are used throughout the minerals industry for both size and density separations. In this study, the performance of a continuous laboratory-scale hindered-settling column was evaluated for various particle systems. The test variables included solids composition, water rate and column height. Column performance was evaluated using partition curves and corresponding performance parameters.

UR - http://www.scopus.com/inward/record.url?scp=1342312119&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=1342312119&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:1342312119

VL - 17

SP - 194

EP - 197

JO - Mining, Metallurgy and Exploration

JF - Mining, Metallurgy and Exploration

SN - 2524-3462

IS - 3

ER -