TY - JOUR
T1 - Identification and remediation of sulfation in lead-acid batteries using cell voltage and pressure sensing
AU - Shi, Ying
AU - Ferone, Christopher A.
AU - Rahn, Christopher D.
N1 - Funding Information:
The authors would like thank the Norfolk Southern Corporation and the Department of Energy for financial support for this work. The authors would also like to thank Lei Cao, Jun Gou, Drs. Chinmay Rao, Yancheng Zhang, and Chao-Yang Wang at The Pennsylvania State University for valuable discussions.
PY - 2013/1/1
Y1 - 2013/1/1
N2 - The operating environment, manufacturing variability, and use can cause different degradation mechanisms to dominate capacity loss inside valve regulated lead-acid (VRLA) batteries. If an aging mechanism for each cell can be identified in real-time, cell usage can be adjusted by the battery management system to optimize the performance and service life of the energy storage system. In this paper, the cell voltage and pressure of new and dead VRLA batteries are monitored during testing to determine the cause of death of the cells. The new cells have fairly uniform performance with limited signs of degradation while the cells in the dead battery have widely ranging performance, especially at the end of discharge and charge. Based on the measurement data, it appears that one cell died from sulfation and another three died of dehydration. The battery capacity is mainly dictated by the sulfated cell. A desulfation charging control scheme with pressure feedback is designed to break up hard sulfate and recover capacity while minimizing water loss by using low current charging. The capacity of the cell is recovered by 41% with minimal water loss, demonstrating the effectiveness of the desulfation charge controller.
AB - The operating environment, manufacturing variability, and use can cause different degradation mechanisms to dominate capacity loss inside valve regulated lead-acid (VRLA) batteries. If an aging mechanism for each cell can be identified in real-time, cell usage can be adjusted by the battery management system to optimize the performance and service life of the energy storage system. In this paper, the cell voltage and pressure of new and dead VRLA batteries are monitored during testing to determine the cause of death of the cells. The new cells have fairly uniform performance with limited signs of degradation while the cells in the dead battery have widely ranging performance, especially at the end of discharge and charge. Based on the measurement data, it appears that one cell died from sulfation and another three died of dehydration. The battery capacity is mainly dictated by the sulfated cell. A desulfation charging control scheme with pressure feedback is designed to break up hard sulfate and recover capacity while minimizing water loss by using low current charging. The capacity of the cell is recovered by 41% with minimal water loss, demonstrating the effectiveness of the desulfation charge controller.
UR - http://www.scopus.com/inward/record.url?scp=84865546606&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84865546606&partnerID=8YFLogxK
U2 - 10.1016/j.jpowsour.2012.08.013
DO - 10.1016/j.jpowsour.2012.08.013
M3 - Article
AN - SCOPUS:84865546606
SN - 0378-7753
VL - 221
SP - 177
EP - 185
JO - Journal of Power Sources
JF - Journal of Power Sources
ER -