Abstract

The substitution of digital representations for analog images provides access to methods for digital storage and transmission and enables the use of a variety of digital image processing techniques, including enhancement and computer assisted screening and diagnosis. Lossy compression can further improve the efficiency of transmission and storage and can facilitate subsequent image processing. Both digitization (or digital acquisition) and lossy compression alter an image from its traditional form, and hence it becomes important that any such alteration be shown to improve or at least not damage the utility of the image in a screening or diagnostic application. One approach to demonstrating in a quantifiable manner that a specific image mode is at least equal to another is by clinical experiment simulating ordinary practice and suitable statistical analysis. In this paper we describe a general protocol for performing such a verification and present preliminary results of a specific experiment designed to show that 12 bpp digital mammograms compressed in a lossy fashion to 0.015 bpp using an embedded wavelet coding scheme result in no significant differences from the analog or digital originals.

Original languageEnglish (US)
Pages (from-to)189-210
Number of pages22
JournalSignal Processing
Volume59
Issue number2
StatePublished - Jun 1 1997

Fingerprint

Image quality
Screening
Image processing
Digital storage
Analog to digital conversion
Statistical methods
Substitution reactions
Experiments
Network protocols

All Science Journal Classification (ASJC) codes

  • Control and Systems Engineering
  • Software
  • Signal Processing
  • Computer Vision and Pattern Recognition
  • Electrical and Electronic Engineering

Cite this

Perlmutter, S. M., Cosman, P. C., Gray, R. M., Olshen, R. A., Ikeda, D., Adams, C. N., ... Daniel, B. L. (1997). Image quality in lossy compressed digital mammograms. Signal Processing, 59(2), 189-210.
Perlmutter, S. M. ; Cosman, P. C. ; Gray, R. M. ; Olshen, R. A. ; Ikeda, D. ; Adams, C. N. ; Betts, B. J. ; Williams, M. B. ; Perlmutter, K. O. ; Li, Jia ; Aiyer, A. ; Fajardo, L. ; Birdwell, R. ; Daniel, B. L. / Image quality in lossy compressed digital mammograms. In: Signal Processing. 1997 ; Vol. 59, No. 2. pp. 189-210.
@article{7cd1927a950c49f488719dff140d40d2,
title = "Image quality in lossy compressed digital mammograms",
abstract = "The substitution of digital representations for analog images provides access to methods for digital storage and transmission and enables the use of a variety of digital image processing techniques, including enhancement and computer assisted screening and diagnosis. Lossy compression can further improve the efficiency of transmission and storage and can facilitate subsequent image processing. Both digitization (or digital acquisition) and lossy compression alter an image from its traditional form, and hence it becomes important that any such alteration be shown to improve or at least not damage the utility of the image in a screening or diagnostic application. One approach to demonstrating in a quantifiable manner that a specific image mode is at least equal to another is by clinical experiment simulating ordinary practice and suitable statistical analysis. In this paper we describe a general protocol for performing such a verification and present preliminary results of a specific experiment designed to show that 12 bpp digital mammograms compressed in a lossy fashion to 0.015 bpp using an embedded wavelet coding scheme result in no significant differences from the analog or digital originals.",
author = "Perlmutter, {S. M.} and Cosman, {P. C.} and Gray, {R. M.} and Olshen, {R. A.} and D. Ikeda and Adams, {C. N.} and Betts, {B. J.} and Williams, {M. B.} and Perlmutter, {K. O.} and Jia Li and A. Aiyer and L. Fajardo and R. Birdwell and Daniel, {B. L.}",
year = "1997",
month = "6",
day = "1",
language = "English (US)",
volume = "59",
pages = "189--210",
journal = "Signal Processing",
issn = "0165-1684",
publisher = "Elsevier",
number = "2",

}

Perlmutter, SM, Cosman, PC, Gray, RM, Olshen, RA, Ikeda, D, Adams, CN, Betts, BJ, Williams, MB, Perlmutter, KO, Li, J, Aiyer, A, Fajardo, L, Birdwell, R & Daniel, BL 1997, 'Image quality in lossy compressed digital mammograms', Signal Processing, vol. 59, no. 2, pp. 189-210.

Image quality in lossy compressed digital mammograms. / Perlmutter, S. M.; Cosman, P. C.; Gray, R. M.; Olshen, R. A.; Ikeda, D.; Adams, C. N.; Betts, B. J.; Williams, M. B.; Perlmutter, K. O.; Li, Jia; Aiyer, A.; Fajardo, L.; Birdwell, R.; Daniel, B. L.

In: Signal Processing, Vol. 59, No. 2, 01.06.1997, p. 189-210.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Image quality in lossy compressed digital mammograms

AU - Perlmutter, S. M.

AU - Cosman, P. C.

AU - Gray, R. M.

AU - Olshen, R. A.

AU - Ikeda, D.

AU - Adams, C. N.

AU - Betts, B. J.

AU - Williams, M. B.

AU - Perlmutter, K. O.

AU - Li, Jia

AU - Aiyer, A.

AU - Fajardo, L.

AU - Birdwell, R.

AU - Daniel, B. L.

PY - 1997/6/1

Y1 - 1997/6/1

N2 - The substitution of digital representations for analog images provides access to methods for digital storage and transmission and enables the use of a variety of digital image processing techniques, including enhancement and computer assisted screening and diagnosis. Lossy compression can further improve the efficiency of transmission and storage and can facilitate subsequent image processing. Both digitization (or digital acquisition) and lossy compression alter an image from its traditional form, and hence it becomes important that any such alteration be shown to improve or at least not damage the utility of the image in a screening or diagnostic application. One approach to demonstrating in a quantifiable manner that a specific image mode is at least equal to another is by clinical experiment simulating ordinary practice and suitable statistical analysis. In this paper we describe a general protocol for performing such a verification and present preliminary results of a specific experiment designed to show that 12 bpp digital mammograms compressed in a lossy fashion to 0.015 bpp using an embedded wavelet coding scheme result in no significant differences from the analog or digital originals.

AB - The substitution of digital representations for analog images provides access to methods for digital storage and transmission and enables the use of a variety of digital image processing techniques, including enhancement and computer assisted screening and diagnosis. Lossy compression can further improve the efficiency of transmission and storage and can facilitate subsequent image processing. Both digitization (or digital acquisition) and lossy compression alter an image from its traditional form, and hence it becomes important that any such alteration be shown to improve or at least not damage the utility of the image in a screening or diagnostic application. One approach to demonstrating in a quantifiable manner that a specific image mode is at least equal to another is by clinical experiment simulating ordinary practice and suitable statistical analysis. In this paper we describe a general protocol for performing such a verification and present preliminary results of a specific experiment designed to show that 12 bpp digital mammograms compressed in a lossy fashion to 0.015 bpp using an embedded wavelet coding scheme result in no significant differences from the analog or digital originals.

UR - http://www.scopus.com/inward/record.url?scp=0031150294&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0031150294&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:0031150294

VL - 59

SP - 189

EP - 210

JO - Signal Processing

JF - Signal Processing

SN - 0165-1684

IS - 2

ER -

Perlmutter SM, Cosman PC, Gray RM, Olshen RA, Ikeda D, Adams CN et al. Image quality in lossy compressed digital mammograms. Signal Processing. 1997 Jun 1;59(2):189-210.