Abstract
The objective of this study was to compare the effects of nonpulsatile and ECG-synchronized pulsatile extracorporeal life support on coronary and carotid blood flow velocities using transthoracic echocardiography and vascular ultrasound, respectively. Nine adult swine were randomly separated into nonpulsatile (NP, n = 5) and pulsatile (P, N = 4) groups and placed on ECLS for 24 h using an i-cor ECLS system. Noninvasive transthoracic images of the left and right coronary artery and the left carotid artery were acquired at the pre-ECLS (baseline), 30 min, 3, 6, 9, 12, and 24 h on-ECLS stages. The mean diastolic velocity of the left and right coronary arteries in the NP group significantly decreased after 24 h on ECLS compared to the baseline and 30 min ECLS stages (P < 0.05). There was no statistical difference in the mean diastolic velocity of the coronary arteries in the P group at 30 min, 3-, 6-, 9-, 12-, and 24-h ECLS compared to baseline. The P group showed a smaller decrease in the mean diastolic velocity of coronary arteries between the 30-min ECLS and 3-, 6-, 9-, 13-, 24-h ECLS stages compared to the NP group. The diastolic velocity of the left carotid artery in the NP group significantly decreased during 24-h ECLS compared to the P group (P < 0.05). An ECG-synchronized pulsatile ECLS system appeared to maintain coronary and carotid artery diastolic velocities better than conventional nonpulsatile ECLS. Further investigation of the perfusion modes during ECLS is warranted.
Original language | English (US) |
---|---|
Pages (from-to) | 918-921 |
Number of pages | 4 |
Journal | Artificial organs |
Volume | 42 |
Issue number | 9 |
DOIs | |
State | Published - Sep 1 2018 |
Fingerprint
All Science Journal Classification (ASJC) codes
- Bioengineering
- Medicine (miscellaneous)
- Biomaterials
- Biomedical Engineering
Cite this
}
Impact of Different Perfusion Modalities on Coronary and Carotid Blood Flow Velocities in an Adult ECLS Swine Model. / Wang, Shigang; Patel, Sunil; Izer, Jenelle; Clark, Joseph; Kunselman, Allen; Wilson, Ronald; Undar, Akif.
In: Artificial organs, Vol. 42, No. 9, 01.09.2018, p. 918-921.Research output: Contribution to journal › Article
TY - JOUR
T1 - Impact of Different Perfusion Modalities on Coronary and Carotid Blood Flow Velocities in an Adult ECLS Swine Model
AU - Wang, Shigang
AU - Patel, Sunil
AU - Izer, Jenelle
AU - Clark, Joseph
AU - Kunselman, Allen
AU - Wilson, Ronald
AU - Undar, Akif
PY - 2018/9/1
Y1 - 2018/9/1
N2 - The objective of this study was to compare the effects of nonpulsatile and ECG-synchronized pulsatile extracorporeal life support on coronary and carotid blood flow velocities using transthoracic echocardiography and vascular ultrasound, respectively. Nine adult swine were randomly separated into nonpulsatile (NP, n = 5) and pulsatile (P, N = 4) groups and placed on ECLS for 24 h using an i-cor ECLS system. Noninvasive transthoracic images of the left and right coronary artery and the left carotid artery were acquired at the pre-ECLS (baseline), 30 min, 3, 6, 9, 12, and 24 h on-ECLS stages. The mean diastolic velocity of the left and right coronary arteries in the NP group significantly decreased after 24 h on ECLS compared to the baseline and 30 min ECLS stages (P < 0.05). There was no statistical difference in the mean diastolic velocity of the coronary arteries in the P group at 30 min, 3-, 6-, 9-, 12-, and 24-h ECLS compared to baseline. The P group showed a smaller decrease in the mean diastolic velocity of coronary arteries between the 30-min ECLS and 3-, 6-, 9-, 13-, 24-h ECLS stages compared to the NP group. The diastolic velocity of the left carotid artery in the NP group significantly decreased during 24-h ECLS compared to the P group (P < 0.05). An ECG-synchronized pulsatile ECLS system appeared to maintain coronary and carotid artery diastolic velocities better than conventional nonpulsatile ECLS. Further investigation of the perfusion modes during ECLS is warranted.
AB - The objective of this study was to compare the effects of nonpulsatile and ECG-synchronized pulsatile extracorporeal life support on coronary and carotid blood flow velocities using transthoracic echocardiography and vascular ultrasound, respectively. Nine adult swine were randomly separated into nonpulsatile (NP, n = 5) and pulsatile (P, N = 4) groups and placed on ECLS for 24 h using an i-cor ECLS system. Noninvasive transthoracic images of the left and right coronary artery and the left carotid artery were acquired at the pre-ECLS (baseline), 30 min, 3, 6, 9, 12, and 24 h on-ECLS stages. The mean diastolic velocity of the left and right coronary arteries in the NP group significantly decreased after 24 h on ECLS compared to the baseline and 30 min ECLS stages (P < 0.05). There was no statistical difference in the mean diastolic velocity of the coronary arteries in the P group at 30 min, 3-, 6-, 9-, 12-, and 24-h ECLS compared to baseline. The P group showed a smaller decrease in the mean diastolic velocity of coronary arteries between the 30-min ECLS and 3-, 6-, 9-, 13-, 24-h ECLS stages compared to the NP group. The diastolic velocity of the left carotid artery in the NP group significantly decreased during 24-h ECLS compared to the P group (P < 0.05). An ECG-synchronized pulsatile ECLS system appeared to maintain coronary and carotid artery diastolic velocities better than conventional nonpulsatile ECLS. Further investigation of the perfusion modes during ECLS is warranted.
UR - http://www.scopus.com/inward/record.url?scp=85045708714&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85045708714&partnerID=8YFLogxK
U2 - 10.1111/aor.13141
DO - 10.1111/aor.13141
M3 - Article
C2 - 29660857
AN - SCOPUS:85045708714
VL - 42
SP - 918
EP - 921
JO - Artificial Organs
JF - Artificial Organs
SN - 0160-564X
IS - 9
ER -