Implementation of Fiducial-Based Image Registration in the Cyberknife Robotic System

Cheng B. Saw, Hungcheng Chen, Henry Wagner

Research output: Contribution to journalArticle

6 Citations (Scopus)

Abstract

Fiducial-based image registration methodology as implemented in the Cyberknife system is explored. The Cyberknife is a radiosurgery system that uses image guidance technology and computer-controlled robotics to determine target positions and adjust beam directions accordingly during the dose delivery. The image guidance system consists of 2 x-ray sources mounted on the ceiling and a detection system mounted on both sides of the treatment couch. Two orthogonal live radiographs are taken prior to and during patient treatment. Fiducial markers are identified on these radiographs and compared to a library of digital reconstructed radiographs (DRRs) using the fiducial extraction software. The fiducial extraction software initially sets an intensity threshold on the live radiographs to generate white areas on black images referred to as "blobs." Different threshold values are being used and blobs at the same location are assumed to originate from the same object. The number of blobs is then reduced by examining each blob against a predefined set of properties such as shape and exposure levels. The remaining blobs are further reduced by examining the location of the blobs in the inferior-superior patient axis. Those blobs that have the corresponding positions are assumed to originate from the same object. The remaining blobs are used to create fiducial configurations and are compared to the reference configuration from the computed tomography (CT) image dataset for treatment planning. The best-fit configuration is considered to have the appropriate fiducial markers. The patient position is determined based on these fiducial markers. During the treatment, the radiation beam is turned off when the Cyberknife changes nodes. This allows a time window to acquire live radiographs for the determination of the patient target position and to update the robotic manipulator to change beam orientations accordingly.

Original languageEnglish (US)
Pages (from-to)156-160
Number of pages5
JournalMedical Dosimetry
Volume33
Issue number2
DOIs
StatePublished - Jun 1 2008

Fingerprint

Fiducial Markers
Robotics
robotics
markers
Software
Digital Libraries
Radiosurgery
Therapeutics
configurations
computer programs
couches
ceilings
thresholds
x ray sources
Tomography
X-Rays
Radiation
Technology
planning
manipulators

All Science Journal Classification (ASJC) codes

  • Radiological and Ultrasound Technology
  • Oncology
  • Radiology Nuclear Medicine and imaging

Cite this

Saw, Cheng B. ; Chen, Hungcheng ; Wagner, Henry. / Implementation of Fiducial-Based Image Registration in the Cyberknife Robotic System. In: Medical Dosimetry. 2008 ; Vol. 33, No. 2. pp. 156-160.
@article{b36e1700fb8d40679bc6d4cbb08d9bff,
title = "Implementation of Fiducial-Based Image Registration in the Cyberknife Robotic System",
abstract = "Fiducial-based image registration methodology as implemented in the Cyberknife system is explored. The Cyberknife is a radiosurgery system that uses image guidance technology and computer-controlled robotics to determine target positions and adjust beam directions accordingly during the dose delivery. The image guidance system consists of 2 x-ray sources mounted on the ceiling and a detection system mounted on both sides of the treatment couch. Two orthogonal live radiographs are taken prior to and during patient treatment. Fiducial markers are identified on these radiographs and compared to a library of digital reconstructed radiographs (DRRs) using the fiducial extraction software. The fiducial extraction software initially sets an intensity threshold on the live radiographs to generate white areas on black images referred to as {"}blobs.{"} Different threshold values are being used and blobs at the same location are assumed to originate from the same object. The number of blobs is then reduced by examining each blob against a predefined set of properties such as shape and exposure levels. The remaining blobs are further reduced by examining the location of the blobs in the inferior-superior patient axis. Those blobs that have the corresponding positions are assumed to originate from the same object. The remaining blobs are used to create fiducial configurations and are compared to the reference configuration from the computed tomography (CT) image dataset for treatment planning. The best-fit configuration is considered to have the appropriate fiducial markers. The patient position is determined based on these fiducial markers. During the treatment, the radiation beam is turned off when the Cyberknife changes nodes. This allows a time window to acquire live radiographs for the determination of the patient target position and to update the robotic manipulator to change beam orientations accordingly.",
author = "Saw, {Cheng B.} and Hungcheng Chen and Henry Wagner",
year = "2008",
month = "6",
day = "1",
doi = "10.1016/j.meddos.2008.03.002",
language = "English (US)",
volume = "33",
pages = "156--160",
journal = "Medical Dosimetry",
issn = "0958-3947",
publisher = "Elsevier Inc.",
number = "2",

}

Implementation of Fiducial-Based Image Registration in the Cyberknife Robotic System. / Saw, Cheng B.; Chen, Hungcheng; Wagner, Henry.

In: Medical Dosimetry, Vol. 33, No. 2, 01.06.2008, p. 156-160.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Implementation of Fiducial-Based Image Registration in the Cyberknife Robotic System

AU - Saw, Cheng B.

AU - Chen, Hungcheng

AU - Wagner, Henry

PY - 2008/6/1

Y1 - 2008/6/1

N2 - Fiducial-based image registration methodology as implemented in the Cyberknife system is explored. The Cyberknife is a radiosurgery system that uses image guidance technology and computer-controlled robotics to determine target positions and adjust beam directions accordingly during the dose delivery. The image guidance system consists of 2 x-ray sources mounted on the ceiling and a detection system mounted on both sides of the treatment couch. Two orthogonal live radiographs are taken prior to and during patient treatment. Fiducial markers are identified on these radiographs and compared to a library of digital reconstructed radiographs (DRRs) using the fiducial extraction software. The fiducial extraction software initially sets an intensity threshold on the live radiographs to generate white areas on black images referred to as "blobs." Different threshold values are being used and blobs at the same location are assumed to originate from the same object. The number of blobs is then reduced by examining each blob against a predefined set of properties such as shape and exposure levels. The remaining blobs are further reduced by examining the location of the blobs in the inferior-superior patient axis. Those blobs that have the corresponding positions are assumed to originate from the same object. The remaining blobs are used to create fiducial configurations and are compared to the reference configuration from the computed tomography (CT) image dataset for treatment planning. The best-fit configuration is considered to have the appropriate fiducial markers. The patient position is determined based on these fiducial markers. During the treatment, the radiation beam is turned off when the Cyberknife changes nodes. This allows a time window to acquire live radiographs for the determination of the patient target position and to update the robotic manipulator to change beam orientations accordingly.

AB - Fiducial-based image registration methodology as implemented in the Cyberknife system is explored. The Cyberknife is a radiosurgery system that uses image guidance technology and computer-controlled robotics to determine target positions and adjust beam directions accordingly during the dose delivery. The image guidance system consists of 2 x-ray sources mounted on the ceiling and a detection system mounted on both sides of the treatment couch. Two orthogonal live radiographs are taken prior to and during patient treatment. Fiducial markers are identified on these radiographs and compared to a library of digital reconstructed radiographs (DRRs) using the fiducial extraction software. The fiducial extraction software initially sets an intensity threshold on the live radiographs to generate white areas on black images referred to as "blobs." Different threshold values are being used and blobs at the same location are assumed to originate from the same object. The number of blobs is then reduced by examining each blob against a predefined set of properties such as shape and exposure levels. The remaining blobs are further reduced by examining the location of the blobs in the inferior-superior patient axis. Those blobs that have the corresponding positions are assumed to originate from the same object. The remaining blobs are used to create fiducial configurations and are compared to the reference configuration from the computed tomography (CT) image dataset for treatment planning. The best-fit configuration is considered to have the appropriate fiducial markers. The patient position is determined based on these fiducial markers. During the treatment, the radiation beam is turned off when the Cyberknife changes nodes. This allows a time window to acquire live radiographs for the determination of the patient target position and to update the robotic manipulator to change beam orientations accordingly.

UR - http://www.scopus.com/inward/record.url?scp=43049095712&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=43049095712&partnerID=8YFLogxK

U2 - 10.1016/j.meddos.2008.03.002

DO - 10.1016/j.meddos.2008.03.002

M3 - Article

C2 - 18456167

AN - SCOPUS:43049095712

VL - 33

SP - 156

EP - 160

JO - Medical Dosimetry

JF - Medical Dosimetry

SN - 0958-3947

IS - 2

ER -