Influence of surgeon's tying technique on knot security.

Erich Batra, D. A. Franz, M. A. Towler, G. T. Rodeheaver, J. G. Thacker, C. A. Zimmer, R. F. Edlich

Research output: Contribution to journalArticle

16 Citations (Scopus)

Abstract

The purpose of this study was to determine the influence of the surgeon's tying technique on knot security using 0 and 2-0 monofilament and multifilament nylon sutures. Using an Instron Tensile Tester and a portable tensiometer, knot security was achieved with these sutures using four-throw square knots (1 = 1 = 1 = 1). After didactic and psychomotor skill training, medical students were taught to construct the four-throw square knot using either a two-hand tie or an instrument tie. Using the portable tensiometer, their knot tying techniques were judged to be superior to those used by surgeons. The surgeon's faulty technique can easily be corrected by didactic information and psychomotor skill training.

Original languageEnglish (US)
Pages (from-to)241-247
Number of pages7
JournalJournal of applied biomaterials : an official journal of the Society for Biomaterials
Volume4
Issue number3
DOIs
StatePublished - Jan 1 1993

Fingerprint

Students

All Science Journal Classification (ASJC) codes

  • Engineering(all)

Cite this

Batra, Erich ; Franz, D. A. ; Towler, M. A. ; Rodeheaver, G. T. ; Thacker, J. G. ; Zimmer, C. A. ; Edlich, R. F. / Influence of surgeon's tying technique on knot security. In: Journal of applied biomaterials : an official journal of the Society for Biomaterials. 1993 ; Vol. 4, No. 3. pp. 241-247.
@article{05245cfa25e045cfbb1dd795913b1dc3,
title = "Influence of surgeon's tying technique on knot security.",
abstract = "The purpose of this study was to determine the influence of the surgeon's tying technique on knot security using 0 and 2-0 monofilament and multifilament nylon sutures. Using an Instron Tensile Tester and a portable tensiometer, knot security was achieved with these sutures using four-throw square knots (1 = 1 = 1 = 1). After didactic and psychomotor skill training, medical students were taught to construct the four-throw square knot using either a two-hand tie or an instrument tie. Using the portable tensiometer, their knot tying techniques were judged to be superior to those used by surgeons. The surgeon's faulty technique can easily be corrected by didactic information and psychomotor skill training.",
author = "Erich Batra and Franz, {D. A.} and Towler, {M. A.} and Rodeheaver, {G. T.} and Thacker, {J. G.} and Zimmer, {C. A.} and Edlich, {R. F.}",
year = "1993",
month = "1",
day = "1",
doi = "10.1002/jab.770040305",
language = "English (US)",
volume = "4",
pages = "241--247",
journal = "Journal of applied biomaterials",
issn = "1045-4861",
publisher = "John Wiley and Sons Inc.",
number = "3",

}

Influence of surgeon's tying technique on knot security. / Batra, Erich; Franz, D. A.; Towler, M. A.; Rodeheaver, G. T.; Thacker, J. G.; Zimmer, C. A.; Edlich, R. F.

In: Journal of applied biomaterials : an official journal of the Society for Biomaterials, Vol. 4, No. 3, 01.01.1993, p. 241-247.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Influence of surgeon's tying technique on knot security.

AU - Batra, Erich

AU - Franz, D. A.

AU - Towler, M. A.

AU - Rodeheaver, G. T.

AU - Thacker, J. G.

AU - Zimmer, C. A.

AU - Edlich, R. F.

PY - 1993/1/1

Y1 - 1993/1/1

N2 - The purpose of this study was to determine the influence of the surgeon's tying technique on knot security using 0 and 2-0 monofilament and multifilament nylon sutures. Using an Instron Tensile Tester and a portable tensiometer, knot security was achieved with these sutures using four-throw square knots (1 = 1 = 1 = 1). After didactic and psychomotor skill training, medical students were taught to construct the four-throw square knot using either a two-hand tie or an instrument tie. Using the portable tensiometer, their knot tying techniques were judged to be superior to those used by surgeons. The surgeon's faulty technique can easily be corrected by didactic information and psychomotor skill training.

AB - The purpose of this study was to determine the influence of the surgeon's tying technique on knot security using 0 and 2-0 monofilament and multifilament nylon sutures. Using an Instron Tensile Tester and a portable tensiometer, knot security was achieved with these sutures using four-throw square knots (1 = 1 = 1 = 1). After didactic and psychomotor skill training, medical students were taught to construct the four-throw square knot using either a two-hand tie or an instrument tie. Using the portable tensiometer, their knot tying techniques were judged to be superior to those used by surgeons. The surgeon's faulty technique can easily be corrected by didactic information and psychomotor skill training.

UR - http://www.scopus.com/inward/record.url?scp=0027670527&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0027670527&partnerID=8YFLogxK

U2 - 10.1002/jab.770040305

DO - 10.1002/jab.770040305

M3 - Article

C2 - 10146307

AN - SCOPUS:0027670527

VL - 4

SP - 241

EP - 247

JO - Journal of applied biomaterials

JF - Journal of applied biomaterials

SN - 1045-4861

IS - 3