Initial clinical experience with the symphony heart assist system

Renzo Cecere, Robert Dowling, Nadia Giannetti

Research output: Contribution to journalArticle

5 Citations (Scopus)

Abstract

Purpose Current cardiac assist devices provide full support, require a major operation, and function asynchronously to the native heart. In contrast, we developed a novel circulatory support device that provides synchronous partial support and can be placed with a minor operation. We report the first clinical implantation with the Symphony device (Abiomed, Danvers, MA). Description Patients with advanced heart failure despite optimal therapy who had exhausted all options were evaluated. A 64-year-old man with ischemic cardiomyopathy underwent implantation of the Symphony device in the right infraclavicular fossa. Evaluation After initiating device support, the cardiac index increased from 1.7 to 2.5 L/min/m2, pulmonary capillary wedge pressure decreased from 26 to 13 mm Hg, right atrial pressure decreased from 12 to 7 mm Hg, creatinine level decreased from 2.3 to 1.5 mg/dL, and New York Heart Association (NYHA) class improved from IIIB to II. Conclusions Placement of the Symphony device resulted in improvements in hemodynamics and functional status. Further clinical data will help define the role for this approach of partial synchronous support through a less invasive operation in patients with advanced heart failure.

Original languageEnglish (US)
Pages (from-to)298-301
Number of pages4
JournalAnnals of Thoracic Surgery
Volume99
Issue number1
DOIs
StatePublished - Jan 1 2015

Fingerprint

Equipment and Supplies
Heart Failure
Pulmonary Wedge Pressure
Atrial Pressure
Cardiomyopathies
Creatinine
Hemodynamics
Therapeutics

All Science Journal Classification (ASJC) codes

  • Surgery
  • Pulmonary and Respiratory Medicine
  • Cardiology and Cardiovascular Medicine

Cite this

Cecere, Renzo ; Dowling, Robert ; Giannetti, Nadia. / Initial clinical experience with the symphony heart assist system. In: Annals of Thoracic Surgery. 2015 ; Vol. 99, No. 1. pp. 298-301.
@article{e73f3f19a1dc4c4faea260be9a4f8a7c,
title = "Initial clinical experience with the symphony heart assist system",
abstract = "Purpose Current cardiac assist devices provide full support, require a major operation, and function asynchronously to the native heart. In contrast, we developed a novel circulatory support device that provides synchronous partial support and can be placed with a minor operation. We report the first clinical implantation with the Symphony device (Abiomed, Danvers, MA). Description Patients with advanced heart failure despite optimal therapy who had exhausted all options were evaluated. A 64-year-old man with ischemic cardiomyopathy underwent implantation of the Symphony device in the right infraclavicular fossa. Evaluation After initiating device support, the cardiac index increased from 1.7 to 2.5 L/min/m2, pulmonary capillary wedge pressure decreased from 26 to 13 mm Hg, right atrial pressure decreased from 12 to 7 mm Hg, creatinine level decreased from 2.3 to 1.5 mg/dL, and New York Heart Association (NYHA) class improved from IIIB to II. Conclusions Placement of the Symphony device resulted in improvements in hemodynamics and functional status. Further clinical data will help define the role for this approach of partial synchronous support through a less invasive operation in patients with advanced heart failure.",
author = "Renzo Cecere and Robert Dowling and Nadia Giannetti",
year = "2015",
month = "1",
day = "1",
doi = "10.1016/j.athoracsur.2014.07.094",
language = "English (US)",
volume = "99",
pages = "298--301",
journal = "Annals of Thoracic Surgery",
issn = "0003-4975",
publisher = "Elsevier USA",
number = "1",

}

Initial clinical experience with the symphony heart assist system. / Cecere, Renzo; Dowling, Robert; Giannetti, Nadia.

In: Annals of Thoracic Surgery, Vol. 99, No. 1, 01.01.2015, p. 298-301.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Initial clinical experience with the symphony heart assist system

AU - Cecere, Renzo

AU - Dowling, Robert

AU - Giannetti, Nadia

PY - 2015/1/1

Y1 - 2015/1/1

N2 - Purpose Current cardiac assist devices provide full support, require a major operation, and function asynchronously to the native heart. In contrast, we developed a novel circulatory support device that provides synchronous partial support and can be placed with a minor operation. We report the first clinical implantation with the Symphony device (Abiomed, Danvers, MA). Description Patients with advanced heart failure despite optimal therapy who had exhausted all options were evaluated. A 64-year-old man with ischemic cardiomyopathy underwent implantation of the Symphony device in the right infraclavicular fossa. Evaluation After initiating device support, the cardiac index increased from 1.7 to 2.5 L/min/m2, pulmonary capillary wedge pressure decreased from 26 to 13 mm Hg, right atrial pressure decreased from 12 to 7 mm Hg, creatinine level decreased from 2.3 to 1.5 mg/dL, and New York Heart Association (NYHA) class improved from IIIB to II. Conclusions Placement of the Symphony device resulted in improvements in hemodynamics and functional status. Further clinical data will help define the role for this approach of partial synchronous support through a less invasive operation in patients with advanced heart failure.

AB - Purpose Current cardiac assist devices provide full support, require a major operation, and function asynchronously to the native heart. In contrast, we developed a novel circulatory support device that provides synchronous partial support and can be placed with a minor operation. We report the first clinical implantation with the Symphony device (Abiomed, Danvers, MA). Description Patients with advanced heart failure despite optimal therapy who had exhausted all options were evaluated. A 64-year-old man with ischemic cardiomyopathy underwent implantation of the Symphony device in the right infraclavicular fossa. Evaluation After initiating device support, the cardiac index increased from 1.7 to 2.5 L/min/m2, pulmonary capillary wedge pressure decreased from 26 to 13 mm Hg, right atrial pressure decreased from 12 to 7 mm Hg, creatinine level decreased from 2.3 to 1.5 mg/dL, and New York Heart Association (NYHA) class improved from IIIB to II. Conclusions Placement of the Symphony device resulted in improvements in hemodynamics and functional status. Further clinical data will help define the role for this approach of partial synchronous support through a less invasive operation in patients with advanced heart failure.

UR - http://www.scopus.com/inward/record.url?scp=84920583528&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84920583528&partnerID=8YFLogxK

U2 - 10.1016/j.athoracsur.2014.07.094

DO - 10.1016/j.athoracsur.2014.07.094

M3 - Article

C2 - 25555946

AN - SCOPUS:84920583528

VL - 99

SP - 298

EP - 301

JO - Annals of Thoracic Surgery

JF - Annals of Thoracic Surgery

SN - 0003-4975

IS - 1

ER -