TY - JOUR
T1 - Insights into the carbon balance for CO2 electroreduction on Cu using gas diffusion electrode reactor designs
AU - Ma, Ming
AU - Clark, Ezra L.
AU - Therkildsen, Kasper T.
AU - Dalsgaard, Sebastian
AU - Chorkendorff, Ib
AU - Seger, Brian
N1 - Funding Information:
This work was supported by the Villum Foundation V-SUSTAIN grant 9455 to the Villum Center for the Science of Sustainable Fuels and Chemicals. This work was also supported by ECOEthy-lene project from the Innovation Fund Denmark (Grant# 8057-00018B).
Publisher Copyright:
© 2020 The Royal Society of Chemistry.
PY - 2020/3
Y1 - 2020/3
N2 - In this work, the carbon balance during high-rate CO2 reduction in flow electrolyzers was rigorously analyzed. The CO2 consumption at gas-diffusion electrodes due to electrochemical conversion and reaction with OH- at the electrode/electrolyte interface leads to a substantial reduction in the volumetric flowrate of gas flow out of the electrolyzer, especially when highly concentrated alkaline electrolytes and elevated current densities are utilized, which is primarily due to an elevated pH at cathode/electrolyte interface. Without considering the CO2 consumption, the faradaic efficiencies for major gas products could be significantly overestimated during high current density CO2 reduction conditions, particularly in the case of high pH electrolyte. In addition, a detailed carbon balance path is elucidated via a two-step procedure of CO2 reaction with OH- at the cathode/electrolyte interface and subsequent CO2 generation at the anode/electrolyte interface caused by a relatively low pH in the vicinity of the anode. Based on the proposed two-step carbon balance path, a systematic exploration of gases released in the anolyte reveals the transformation of a HCO3- or OH- catholyte to a CO32- catholyte, which was further confirmed by pH measurements.
AB - In this work, the carbon balance during high-rate CO2 reduction in flow electrolyzers was rigorously analyzed. The CO2 consumption at gas-diffusion electrodes due to electrochemical conversion and reaction with OH- at the electrode/electrolyte interface leads to a substantial reduction in the volumetric flowrate of gas flow out of the electrolyzer, especially when highly concentrated alkaline electrolytes and elevated current densities are utilized, which is primarily due to an elevated pH at cathode/electrolyte interface. Without considering the CO2 consumption, the faradaic efficiencies for major gas products could be significantly overestimated during high current density CO2 reduction conditions, particularly in the case of high pH electrolyte. In addition, a detailed carbon balance path is elucidated via a two-step procedure of CO2 reaction with OH- at the cathode/electrolyte interface and subsequent CO2 generation at the anode/electrolyte interface caused by a relatively low pH in the vicinity of the anode. Based on the proposed two-step carbon balance path, a systematic exploration of gases released in the anolyte reveals the transformation of a HCO3- or OH- catholyte to a CO32- catholyte, which was further confirmed by pH measurements.
UR - http://www.scopus.com/inward/record.url?scp=85083035936&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85083035936&partnerID=8YFLogxK
U2 - 10.1039/d0ee00047g
DO - 10.1039/d0ee00047g
M3 - Article
AN - SCOPUS:85083035936
SN - 1754-5692
VL - 13
SP - 977
EP - 985
JO - Energy and Environmental Science
JF - Energy and Environmental Science
IS - 3
ER -