Laboratory evaluation of a physiologic sampling pump (PSP)

Ming I. Lin, William A. Groves, Andris Freivalds, Larry Lee, Eun Gyung Lee, James E. Slaven, Martin Harper

Research output: Contribution to journalArticle

4 Citations (Scopus)

Abstract

Recently, physiologic sampling pumps (PSPs), which can adjust their sampling rates in proportion to wearers' minute ventilation (VE), have been proposed to better estimate exposure to airborne contaminants in the workplace. A laboratory evaluation was conducted to compare the performance of a new PSP with a traditional sampling pump (TSP) in an exposure chamber. Fifteen subjects (aged 19-36 years) performed two replicate sessions of step-tests for correlated and uncorrelated exposure scenarios on four separate days. When exposed to a scenario in which subject VE is highly correlated with m-xylene concentration over the sampling period (r = 0.93), the PSP-measured time-weighted average (TWA) concentrations are higher than TSP-measured concentrations (average ratio of PSP to TSP = 1.18). The ratio of PSP- and TSP-measured TWA concentrations for the uncorrelated scenario (r = 0.02) is closer to one, as expected, with an average value of 0.94. The test results of the linear mixed model further indicate that the performance of the PSP is unaffected by the anthropometric and physiological characteristics of the wearer. Potential differences in exposure estimates resulting from the use of the two instruments were examined in light of various schemes which can potentially occur in the field. With the capability of estimating the total volume of air inhaled over the sampling period with improved accuracy, PSPs show promise in reducing the inherent uncertainty in current risk assessment approaches that entail constant-flow (TSP) sampling approaches.

Original languageEnglish (US)
Pages (from-to)1415-1421
Number of pages7
JournalJournal of Environmental Monitoring
Volume12
Issue number7
DOIs
StatePublished - Jul 2010

Fingerprint

Ventilation
pump
Pumps
Sampling
sampling
Exercise Test
Workplace
Uncertainty
Linear Models
Air
evaluation
laboratory
ventilation
3-xylene
xylene
workplace
Risk assessment
risk assessment

All Science Journal Classification (ASJC) codes

  • Public Health, Environmental and Occupational Health
  • Management, Monitoring, Policy and Law

Cite this

Lin, Ming I. ; Groves, William A. ; Freivalds, Andris ; Lee, Larry ; Lee, Eun Gyung ; Slaven, James E. ; Harper, Martin. / Laboratory evaluation of a physiologic sampling pump (PSP). In: Journal of Environmental Monitoring. 2010 ; Vol. 12, No. 7. pp. 1415-1421.
@article{733b3a717646423e8e618ae86ebcf558,
title = "Laboratory evaluation of a physiologic sampling pump (PSP)",
abstract = "Recently, physiologic sampling pumps (PSPs), which can adjust their sampling rates in proportion to wearers' minute ventilation (VE), have been proposed to better estimate exposure to airborne contaminants in the workplace. A laboratory evaluation was conducted to compare the performance of a new PSP with a traditional sampling pump (TSP) in an exposure chamber. Fifteen subjects (aged 19-36 years) performed two replicate sessions of step-tests for correlated and uncorrelated exposure scenarios on four separate days. When exposed to a scenario in which subject VE is highly correlated with m-xylene concentration over the sampling period (r = 0.93), the PSP-measured time-weighted average (TWA) concentrations are higher than TSP-measured concentrations (average ratio of PSP to TSP = 1.18). The ratio of PSP- and TSP-measured TWA concentrations for the uncorrelated scenario (r = 0.02) is closer to one, as expected, with an average value of 0.94. The test results of the linear mixed model further indicate that the performance of the PSP is unaffected by the anthropometric and physiological characteristics of the wearer. Potential differences in exposure estimates resulting from the use of the two instruments were examined in light of various schemes which can potentially occur in the field. With the capability of estimating the total volume of air inhaled over the sampling period with improved accuracy, PSPs show promise in reducing the inherent uncertainty in current risk assessment approaches that entail constant-flow (TSP) sampling approaches.",
author = "Lin, {Ming I.} and Groves, {William A.} and Andris Freivalds and Larry Lee and Lee, {Eun Gyung} and Slaven, {James E.} and Martin Harper",
year = "2010",
month = "7",
doi = "10.1039/b923986c",
language = "English (US)",
volume = "12",
pages = "1415--1421",
journal = "Environmental Sciences: Processes and Impacts",
issn = "2050-7887",
publisher = "Royal Society of Chemistry",
number = "7",

}

Laboratory evaluation of a physiologic sampling pump (PSP). / Lin, Ming I.; Groves, William A.; Freivalds, Andris; Lee, Larry; Lee, Eun Gyung; Slaven, James E.; Harper, Martin.

In: Journal of Environmental Monitoring, Vol. 12, No. 7, 07.2010, p. 1415-1421.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Laboratory evaluation of a physiologic sampling pump (PSP)

AU - Lin, Ming I.

AU - Groves, William A.

AU - Freivalds, Andris

AU - Lee, Larry

AU - Lee, Eun Gyung

AU - Slaven, James E.

AU - Harper, Martin

PY - 2010/7

Y1 - 2010/7

N2 - Recently, physiologic sampling pumps (PSPs), which can adjust their sampling rates in proportion to wearers' minute ventilation (VE), have been proposed to better estimate exposure to airborne contaminants in the workplace. A laboratory evaluation was conducted to compare the performance of a new PSP with a traditional sampling pump (TSP) in an exposure chamber. Fifteen subjects (aged 19-36 years) performed two replicate sessions of step-tests for correlated and uncorrelated exposure scenarios on four separate days. When exposed to a scenario in which subject VE is highly correlated with m-xylene concentration over the sampling period (r = 0.93), the PSP-measured time-weighted average (TWA) concentrations are higher than TSP-measured concentrations (average ratio of PSP to TSP = 1.18). The ratio of PSP- and TSP-measured TWA concentrations for the uncorrelated scenario (r = 0.02) is closer to one, as expected, with an average value of 0.94. The test results of the linear mixed model further indicate that the performance of the PSP is unaffected by the anthropometric and physiological characteristics of the wearer. Potential differences in exposure estimates resulting from the use of the two instruments were examined in light of various schemes which can potentially occur in the field. With the capability of estimating the total volume of air inhaled over the sampling period with improved accuracy, PSPs show promise in reducing the inherent uncertainty in current risk assessment approaches that entail constant-flow (TSP) sampling approaches.

AB - Recently, physiologic sampling pumps (PSPs), which can adjust their sampling rates in proportion to wearers' minute ventilation (VE), have been proposed to better estimate exposure to airborne contaminants in the workplace. A laboratory evaluation was conducted to compare the performance of a new PSP with a traditional sampling pump (TSP) in an exposure chamber. Fifteen subjects (aged 19-36 years) performed two replicate sessions of step-tests for correlated and uncorrelated exposure scenarios on four separate days. When exposed to a scenario in which subject VE is highly correlated with m-xylene concentration over the sampling period (r = 0.93), the PSP-measured time-weighted average (TWA) concentrations are higher than TSP-measured concentrations (average ratio of PSP to TSP = 1.18). The ratio of PSP- and TSP-measured TWA concentrations for the uncorrelated scenario (r = 0.02) is closer to one, as expected, with an average value of 0.94. The test results of the linear mixed model further indicate that the performance of the PSP is unaffected by the anthropometric and physiological characteristics of the wearer. Potential differences in exposure estimates resulting from the use of the two instruments were examined in light of various schemes which can potentially occur in the field. With the capability of estimating the total volume of air inhaled over the sampling period with improved accuracy, PSPs show promise in reducing the inherent uncertainty in current risk assessment approaches that entail constant-flow (TSP) sampling approaches.

UR - http://www.scopus.com/inward/record.url?scp=77954644045&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77954644045&partnerID=8YFLogxK

U2 - 10.1039/b923986c

DO - 10.1039/b923986c

M3 - Article

C2 - 20614096

AN - SCOPUS:77954644045

VL - 12

SP - 1415

EP - 1421

JO - Environmental Sciences: Processes and Impacts

JF - Environmental Sciences: Processes and Impacts

SN - 2050-7887

IS - 7

ER -