Middle cerebral artery blood flow velocity and stable xenon-enhanced computed tomographic blood flow during balloon test occlusion of the internal carotid artery

W. Andrew Kofke, Patric Brauer, Raymond Policare, Susan Penthany, David Barker, Joseph Horton

Research output: Contribution to journalArticlepeer-review

43 Scopus citations

Abstract

and PurposeTranscranial Doppler ultrasonography has been reported to reflect changes in cerebral blood flow (CBF) with the use of radioactive tracer techniques, which are weighted to measure primarily cortical structures. We tested the hypothesis that changes in transcranial Doppler ultrasonography would reflect changes in CBF in the middle cerebral artery vascular territory with the use of stable xenonenhanced CT to assess CBF during carotid occlusion. MethodsThirty-one conscious patients underwent balloon test occlusion of the internal carotid artery and transcranial Doppler ultrasonography and xenon-enhanced CT assessment of blood flow velocity and CBF, respectively, of the middle cerebral artery and its distribution during balloon test occlusion. ResultsA significant correlation was seen between the change in CBF and the change in blood flow velocity for both brain levels at which CBF was determined (P less than.0001). The average change in blood flow velocity was minus 13.4%, and the change in CBF was minus 15.1% and minus 17.7% at the two anatomic levels examined. ConclusionsThe data indicate that changes in blood flow velocity generally reflect changes in CBF throughout the middle cerebral artery vascular territory with abrupt occlusion of the internal carotid artery in unanesthetized humans.

Original languageEnglish (US)
Pages (from-to)1603-1606
Number of pages4
JournalStroke
Volume26
Issue number9
DOIs
StatePublished - Sep 1995

All Science Journal Classification (ASJC) codes

  • Clinical Neurology
  • Cardiology and Cardiovascular Medicine
  • Advanced and Specialized Nursing

Cite this