Migrated Replacement Percutaneous Endoscopic Gastrostomy Tube Leading To Jejunoduodenal Intussusception

Brian P. McAllister, Jayakrishna Chintanaboina, John M. Levenick

Research output: Contribution to journalArticle

Original languageEnglish (US)
Pages (from-to)A29-A30
JournalClinical Gastroenterology and Hepatology
Volume16
Issue number4
DOIs
StatePublished - Apr 2018

Fingerprint

Gastrostomy
Intussusception

All Science Journal Classification (ASJC) codes

  • Hepatology
  • Gastroenterology

Cite this

@article{1b57ba4b39664195add45fcb0b1bc05e,
title = "Migrated Replacement Percutaneous Endoscopic Gastrostomy Tube Leading To Jejunoduodenal Intussusception",
author = "McAllister, {Brian P.} and Jayakrishna Chintanaboina and Levenick, {John M.}",
year = "2018",
month = "4",
doi = "10.1016/j.cgh.2017.07.028",
language = "English (US)",
volume = "16",
pages = "A29--A30",
journal = "Clinical Gastroenterology and Hepatology",
issn = "1542-3565",
publisher = "W.B. Saunders Ltd",
number = "4",

}

Migrated Replacement Percutaneous Endoscopic Gastrostomy Tube Leading To Jejunoduodenal Intussusception. / McAllister, Brian P.; Chintanaboina, Jayakrishna; Levenick, John M.

In: Clinical Gastroenterology and Hepatology, Vol. 16, No. 4, 04.2018, p. A29-A30.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Migrated Replacement Percutaneous Endoscopic Gastrostomy Tube Leading To Jejunoduodenal Intussusception

AU - McAllister, Brian P.

AU - Chintanaboina, Jayakrishna

AU - Levenick, John M.

PY - 2018/4

Y1 - 2018/4

UR - http://www.scopus.com/inward/record.url?scp=85044157436&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85044157436&partnerID=8YFLogxK

U2 - 10.1016/j.cgh.2017.07.028

DO - 10.1016/j.cgh.2017.07.028

M3 - Article

C2 - 28780206

AN - SCOPUS:85044157436

VL - 16

SP - A29-A30

JO - Clinical Gastroenterology and Hepatology

JF - Clinical Gastroenterology and Hepatology

SN - 1542-3565

IS - 4

ER -