Minimizing human tracking error for robotic rehabilitation device

Andrew J. Homich, Megan A. Doerzbacher, Eric L. Tschantz, Stephen Jacob Piazza, Everett Hills, Jason Zachary Moore

Research output: Contribution to journalArticle

5 Citations (Scopus)

Abstract

This paper explores the design of a novel robotic device for gait training and rehabilitation, a method to estimate a human's orientation within the rehabilitation device, as well as an optimal state space controller to actuate the rehabilitation device. The robotic parallel bars (RPBs) were designed to address the shortcomings of currently available assistive devices. The RPB device moves in response to a human occupant to maintain a constant distance and orientation to the human. To minimize the error in tracking the human, a complementary filter was optimized to estimate the human's orientation within the device using a magnetometer and gyroscope. Experimental measurements of complementary filter performance on a test platform show that the filter estimates orientation with an average error of 0.62 deg over a range of angular velocities from 22.5 deg/s to 180 deg/s. The RPB device response was simulated, and an optimal state space controller was implemented using a linear quadratic regulator (LQR). The controller has an average position error of 14.1 cm and an average orientation error of 14.3 deg when tracking a human, while the simulation predicted an average error of 10.5 cm and 5.6 deg. The achieved level of accuracy in following a human user is sufficiently sensitive for the RPB device to conduct more advanced, realistic gait training and rehabilitation techniques for mobility impaired patients able to safely support their body weight with their legs and arms.

Original languageEnglish (US)
Article number041003
JournalJournal of Medical Devices, Transactions of the ASME
Volume9
Issue number4
DOIs
StatePublished - Jan 1 2015

Fingerprint

Robotics
Patient rehabilitation
Rehabilitation
Equipment and Supplies
Controllers
Gait
Gyroscopes
Angular velocity
Magnetometers
Self-Help Devices
Leg
Teaching
Arm
Body Weight

All Science Journal Classification (ASJC) codes

  • Medicine (miscellaneous)
  • Biomedical Engineering

Cite this

@article{5c179b3a4b1642fc8392ba31046bfd50,
title = "Minimizing human tracking error for robotic rehabilitation device",
abstract = "This paper explores the design of a novel robotic device for gait training and rehabilitation, a method to estimate a human's orientation within the rehabilitation device, as well as an optimal state space controller to actuate the rehabilitation device. The robotic parallel bars (RPBs) were designed to address the shortcomings of currently available assistive devices. The RPB device moves in response to a human occupant to maintain a constant distance and orientation to the human. To minimize the error in tracking the human, a complementary filter was optimized to estimate the human's orientation within the device using a magnetometer and gyroscope. Experimental measurements of complementary filter performance on a test platform show that the filter estimates orientation with an average error of 0.62 deg over a range of angular velocities from 22.5 deg/s to 180 deg/s. The RPB device response was simulated, and an optimal state space controller was implemented using a linear quadratic regulator (LQR). The controller has an average position error of 14.1 cm and an average orientation error of 14.3 deg when tracking a human, while the simulation predicted an average error of 10.5 cm and 5.6 deg. The achieved level of accuracy in following a human user is sufficiently sensitive for the RPB device to conduct more advanced, realistic gait training and rehabilitation techniques for mobility impaired patients able to safely support their body weight with their legs and arms.",
author = "Homich, {Andrew J.} and Doerzbacher, {Megan A.} and Tschantz, {Eric L.} and Piazza, {Stephen Jacob} and Everett Hills and Moore, {Jason Zachary}",
year = "2015",
month = "1",
day = "1",
doi = "10.1115/1.4030275",
language = "English (US)",
volume = "9",
journal = "Journal of Medical Devices, Transactions of the ASME",
issn = "1932-6181",
publisher = "American Society of Mechanical Engineers(ASME)",
number = "4",

}

Minimizing human tracking error for robotic rehabilitation device. / Homich, Andrew J.; Doerzbacher, Megan A.; Tschantz, Eric L.; Piazza, Stephen Jacob; Hills, Everett; Moore, Jason Zachary.

In: Journal of Medical Devices, Transactions of the ASME, Vol. 9, No. 4, 041003, 01.01.2015.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Minimizing human tracking error for robotic rehabilitation device

AU - Homich, Andrew J.

AU - Doerzbacher, Megan A.

AU - Tschantz, Eric L.

AU - Piazza, Stephen Jacob

AU - Hills, Everett

AU - Moore, Jason Zachary

PY - 2015/1/1

Y1 - 2015/1/1

N2 - This paper explores the design of a novel robotic device for gait training and rehabilitation, a method to estimate a human's orientation within the rehabilitation device, as well as an optimal state space controller to actuate the rehabilitation device. The robotic parallel bars (RPBs) were designed to address the shortcomings of currently available assistive devices. The RPB device moves in response to a human occupant to maintain a constant distance and orientation to the human. To minimize the error in tracking the human, a complementary filter was optimized to estimate the human's orientation within the device using a magnetometer and gyroscope. Experimental measurements of complementary filter performance on a test platform show that the filter estimates orientation with an average error of 0.62 deg over a range of angular velocities from 22.5 deg/s to 180 deg/s. The RPB device response was simulated, and an optimal state space controller was implemented using a linear quadratic regulator (LQR). The controller has an average position error of 14.1 cm and an average orientation error of 14.3 deg when tracking a human, while the simulation predicted an average error of 10.5 cm and 5.6 deg. The achieved level of accuracy in following a human user is sufficiently sensitive for the RPB device to conduct more advanced, realistic gait training and rehabilitation techniques for mobility impaired patients able to safely support their body weight with their legs and arms.

AB - This paper explores the design of a novel robotic device for gait training and rehabilitation, a method to estimate a human's orientation within the rehabilitation device, as well as an optimal state space controller to actuate the rehabilitation device. The robotic parallel bars (RPBs) were designed to address the shortcomings of currently available assistive devices. The RPB device moves in response to a human occupant to maintain a constant distance and orientation to the human. To minimize the error in tracking the human, a complementary filter was optimized to estimate the human's orientation within the device using a magnetometer and gyroscope. Experimental measurements of complementary filter performance on a test platform show that the filter estimates orientation with an average error of 0.62 deg over a range of angular velocities from 22.5 deg/s to 180 deg/s. The RPB device response was simulated, and an optimal state space controller was implemented using a linear quadratic regulator (LQR). The controller has an average position error of 14.1 cm and an average orientation error of 14.3 deg when tracking a human, while the simulation predicted an average error of 10.5 cm and 5.6 deg. The achieved level of accuracy in following a human user is sufficiently sensitive for the RPB device to conduct more advanced, realistic gait training and rehabilitation techniques for mobility impaired patients able to safely support their body weight with their legs and arms.

UR - http://www.scopus.com/inward/record.url?scp=84939523053&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84939523053&partnerID=8YFLogxK

U2 - 10.1115/1.4030275

DO - 10.1115/1.4030275

M3 - Article

AN - SCOPUS:84939523053

VL - 9

JO - Journal of Medical Devices, Transactions of the ASME

JF - Journal of Medical Devices, Transactions of the ASME

SN - 1932-6181

IS - 4

M1 - 041003

ER -