Multiplane particle shadow velocimetry to quantify integral length scales

Christine Truong, Steven S. Hinkle, Jeff R. Harris, Michael H. Krane, Kyle M. Sinding, Rhett William Jefferies, Tiffany A. Camp, Arnold Anthony Fontaine

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

The integral length scale can be calculated from planar particle image velocimetry (PIV) data by integrating a two-point velocity correlation over a range of in-plane spatial separations. However, the field of view restricts the integral scale that can be measured by limiting the integration domain. This limitation can be overcome if multiple planes are imaged, and velocity is correlated along the out-of-plane direction. Multiplane particle shadow velocimetry (PSV) is introduced for this purpose. A backlight is used to illuminate particles in the flow field, rather than a laser sheet as in PIV. These illuminated particles obstruct light from entering the camera, thus appearing dark. The combination of two colors in the backlight and a dichroic mirror makes possible the simultaneous imaging of two planes. Separated along the the out-of-plane direction (the optical axis), the multiple imaged planes allow for an integral length scale to be measured independent of the field of view. Experiments were conducted in the axisymmetric 285 mm diameter glycerin tunnel at Penn State’s Applied Research Laboratory. Turbulence statistics calculated using multiplane PSV are consistent with those obtained using planar PSV and laser Doppler velocimetry (LDV) at the same facility. The temporal autocorrelation and the integral timescale, measured with planar and multiplane PSV, agree within 95% confidence. The two-point velocity correlation separated spatially along the in-plane radial direction is the same, within 95% confidence, as that separated spatially along the out-of-plane radial direction. The former is insufficient for calculating an integral length scale due to its limited domain. Integrating the latter yields an integral length scale equal to 11% of the radius of the tunnel.

Original languageEnglish (US)
Article number73
JournalExperiments in Fluids
Volume59
Issue number4
DOIs
StatePublished - Apr 1 2018

Fingerprint

Velocity measurement
particle image velocimetry
field of view
tunnels
confidence
Lasers
autocorrelation
lasers
Research laboratories
Glycerol
Autocorrelation
flow distribution
Wind tunnels
turbulence
cameras
statistics
Flow fields
Tunnels
Mirrors
mirrors

All Science Journal Classification (ASJC) codes

  • Computational Mechanics
  • Mechanics of Materials
  • Physics and Astronomy(all)
  • Fluid Flow and Transfer Processes

Cite this

@article{f2098c8065a749409c32f58cc4ee9808,
title = "Multiplane particle shadow velocimetry to quantify integral length scales",
abstract = "The integral length scale can be calculated from planar particle image velocimetry (PIV) data by integrating a two-point velocity correlation over a range of in-plane spatial separations. However, the field of view restricts the integral scale that can be measured by limiting the integration domain. This limitation can be overcome if multiple planes are imaged, and velocity is correlated along the out-of-plane direction. Multiplane particle shadow velocimetry (PSV) is introduced for this purpose. A backlight is used to illuminate particles in the flow field, rather than a laser sheet as in PIV. These illuminated particles obstruct light from entering the camera, thus appearing dark. The combination of two colors in the backlight and a dichroic mirror makes possible the simultaneous imaging of two planes. Separated along the the out-of-plane direction (the optical axis), the multiple imaged planes allow for an integral length scale to be measured independent of the field of view. Experiments were conducted in the axisymmetric 285 mm diameter glycerin tunnel at Penn State’s Applied Research Laboratory. Turbulence statistics calculated using multiplane PSV are consistent with those obtained using planar PSV and laser Doppler velocimetry (LDV) at the same facility. The temporal autocorrelation and the integral timescale, measured with planar and multiplane PSV, agree within 95{\%} confidence. The two-point velocity correlation separated spatially along the in-plane radial direction is the same, within 95{\%} confidence, as that separated spatially along the out-of-plane radial direction. The former is insufficient for calculating an integral length scale due to its limited domain. Integrating the latter yields an integral length scale equal to 11{\%} of the radius of the tunnel.",
author = "Christine Truong and Hinkle, {Steven S.} and Harris, {Jeff R.} and Krane, {Michael H.} and Sinding, {Kyle M.} and Jefferies, {Rhett William} and Camp, {Tiffany A.} and Fontaine, {Arnold Anthony}",
year = "2018",
month = "4",
day = "1",
doi = "10.1007/s00348-018-2528-x",
language = "English (US)",
volume = "59",
journal = "Experiments in Fluids",
issn = "0723-4864",
publisher = "Springer Verlag",
number = "4",

}

Multiplane particle shadow velocimetry to quantify integral length scales. / Truong, Christine; Hinkle, Steven S.; Harris, Jeff R.; Krane, Michael H.; Sinding, Kyle M.; Jefferies, Rhett William; Camp, Tiffany A.; Fontaine, Arnold Anthony.

In: Experiments in Fluids, Vol. 59, No. 4, 73, 01.04.2018.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Multiplane particle shadow velocimetry to quantify integral length scales

AU - Truong, Christine

AU - Hinkle, Steven S.

AU - Harris, Jeff R.

AU - Krane, Michael H.

AU - Sinding, Kyle M.

AU - Jefferies, Rhett William

AU - Camp, Tiffany A.

AU - Fontaine, Arnold Anthony

PY - 2018/4/1

Y1 - 2018/4/1

N2 - The integral length scale can be calculated from planar particle image velocimetry (PIV) data by integrating a two-point velocity correlation over a range of in-plane spatial separations. However, the field of view restricts the integral scale that can be measured by limiting the integration domain. This limitation can be overcome if multiple planes are imaged, and velocity is correlated along the out-of-plane direction. Multiplane particle shadow velocimetry (PSV) is introduced for this purpose. A backlight is used to illuminate particles in the flow field, rather than a laser sheet as in PIV. These illuminated particles obstruct light from entering the camera, thus appearing dark. The combination of two colors in the backlight and a dichroic mirror makes possible the simultaneous imaging of two planes. Separated along the the out-of-plane direction (the optical axis), the multiple imaged planes allow for an integral length scale to be measured independent of the field of view. Experiments were conducted in the axisymmetric 285 mm diameter glycerin tunnel at Penn State’s Applied Research Laboratory. Turbulence statistics calculated using multiplane PSV are consistent with those obtained using planar PSV and laser Doppler velocimetry (LDV) at the same facility. The temporal autocorrelation and the integral timescale, measured with planar and multiplane PSV, agree within 95% confidence. The two-point velocity correlation separated spatially along the in-plane radial direction is the same, within 95% confidence, as that separated spatially along the out-of-plane radial direction. The former is insufficient for calculating an integral length scale due to its limited domain. Integrating the latter yields an integral length scale equal to 11% of the radius of the tunnel.

AB - The integral length scale can be calculated from planar particle image velocimetry (PIV) data by integrating a two-point velocity correlation over a range of in-plane spatial separations. However, the field of view restricts the integral scale that can be measured by limiting the integration domain. This limitation can be overcome if multiple planes are imaged, and velocity is correlated along the out-of-plane direction. Multiplane particle shadow velocimetry (PSV) is introduced for this purpose. A backlight is used to illuminate particles in the flow field, rather than a laser sheet as in PIV. These illuminated particles obstruct light from entering the camera, thus appearing dark. The combination of two colors in the backlight and a dichroic mirror makes possible the simultaneous imaging of two planes. Separated along the the out-of-plane direction (the optical axis), the multiple imaged planes allow for an integral length scale to be measured independent of the field of view. Experiments were conducted in the axisymmetric 285 mm diameter glycerin tunnel at Penn State’s Applied Research Laboratory. Turbulence statistics calculated using multiplane PSV are consistent with those obtained using planar PSV and laser Doppler velocimetry (LDV) at the same facility. The temporal autocorrelation and the integral timescale, measured with planar and multiplane PSV, agree within 95% confidence. The two-point velocity correlation separated spatially along the in-plane radial direction is the same, within 95% confidence, as that separated spatially along the out-of-plane radial direction. The former is insufficient for calculating an integral length scale due to its limited domain. Integrating the latter yields an integral length scale equal to 11% of the radius of the tunnel.

UR - http://www.scopus.com/inward/record.url?scp=85044830068&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85044830068&partnerID=8YFLogxK

U2 - 10.1007/s00348-018-2528-x

DO - 10.1007/s00348-018-2528-x

M3 - Article

VL - 59

JO - Experiments in Fluids

JF - Experiments in Fluids

SN - 0723-4864

IS - 4

M1 - 73

ER -