Musculoskeletal imaging at 3T: Current techniques and future applications

Research output: Contribution to journalReview article

62 Citations (Scopus)

Abstract

MSK MR imaging applications are making the transition rapidly from 1.5T to 3T. Initial experience in the knee suggests that the higher SNR provides technical improvement in routine clinical imaging with the potential for greater accuracy in the diagnosis of articular cartilage injury. Similarly, initial experience with 3T MR imaging in the evaluation of the hip and small joints of the hand and wrist has been positive. In other joints, clinical development has been limited by the lack of availability of dedicated surface coils, and sensitivity of 3T MR imaging to artifact. The clinical impact of this technology remains uncertain because no published controlled clinical trial has evaluated the impact of 3T MR imaging on diagnostic outcomes. In addition to clinical application, 3T MR imaging has an important role for furthering translational research in MSK diseases through the development of new molecular and functional MR imaging techniques.

Original languageEnglish (US)
Pages (from-to)63-76
Number of pages14
JournalMagnetic Resonance Imaging Clinics of North America
Volume14
Issue number1
DOIs
StatePublished - Jan 1 2006

Fingerprint

Translational Medical Research
Hip Joint
Controlled Clinical Trials
Articular Cartilage
Diagnostic Imaging
Wrist
Artifacts
Knee
Hand
Joints
Technology
Wounds and Injuries

All Science Journal Classification (ASJC) codes

  • Radiology Nuclear Medicine and imaging

Cite this

@article{0b596a7eddbe481c88059a8cf56a6c65,
title = "Musculoskeletal imaging at 3T: Current techniques and future applications",
abstract = "MSK MR imaging applications are making the transition rapidly from 1.5T to 3T. Initial experience in the knee suggests that the higher SNR provides technical improvement in routine clinical imaging with the potential for greater accuracy in the diagnosis of articular cartilage injury. Similarly, initial experience with 3T MR imaging in the evaluation of the hip and small joints of the hand and wrist has been positive. In other joints, clinical development has been limited by the lack of availability of dedicated surface coils, and sensitivity of 3T MR imaging to artifact. The clinical impact of this technology remains uncertain because no published controlled clinical trial has evaluated the impact of 3T MR imaging on diagnostic outcomes. In addition to clinical application, 3T MR imaging has an important role for furthering translational research in MSK diseases through the development of new molecular and functional MR imaging techniques.",
author = "Timothy Mosher",
year = "2006",
month = "1",
day = "1",
doi = "10.1016/j.mric.2005.12.002",
language = "English (US)",
volume = "14",
pages = "63--76",
journal = "Magnetic Resonance Imaging Clinics of North America",
issn = "1064-9689",
publisher = "W.B. Saunders Ltd",
number = "1",

}

Musculoskeletal imaging at 3T : Current techniques and future applications. / Mosher, Timothy.

In: Magnetic Resonance Imaging Clinics of North America, Vol. 14, No. 1, 01.01.2006, p. 63-76.

Research output: Contribution to journalReview article

TY - JOUR

T1 - Musculoskeletal imaging at 3T

T2 - Current techniques and future applications

AU - Mosher, Timothy

PY - 2006/1/1

Y1 - 2006/1/1

N2 - MSK MR imaging applications are making the transition rapidly from 1.5T to 3T. Initial experience in the knee suggests that the higher SNR provides technical improvement in routine clinical imaging with the potential for greater accuracy in the diagnosis of articular cartilage injury. Similarly, initial experience with 3T MR imaging in the evaluation of the hip and small joints of the hand and wrist has been positive. In other joints, clinical development has been limited by the lack of availability of dedicated surface coils, and sensitivity of 3T MR imaging to artifact. The clinical impact of this technology remains uncertain because no published controlled clinical trial has evaluated the impact of 3T MR imaging on diagnostic outcomes. In addition to clinical application, 3T MR imaging has an important role for furthering translational research in MSK diseases through the development of new molecular and functional MR imaging techniques.

AB - MSK MR imaging applications are making the transition rapidly from 1.5T to 3T. Initial experience in the knee suggests that the higher SNR provides technical improvement in routine clinical imaging with the potential for greater accuracy in the diagnosis of articular cartilage injury. Similarly, initial experience with 3T MR imaging in the evaluation of the hip and small joints of the hand and wrist has been positive. In other joints, clinical development has been limited by the lack of availability of dedicated surface coils, and sensitivity of 3T MR imaging to artifact. The clinical impact of this technology remains uncertain because no published controlled clinical trial has evaluated the impact of 3T MR imaging on diagnostic outcomes. In addition to clinical application, 3T MR imaging has an important role for furthering translational research in MSK diseases through the development of new molecular and functional MR imaging techniques.

UR - http://www.scopus.com/inward/record.url?scp=33644839187&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33644839187&partnerID=8YFLogxK

U2 - 10.1016/j.mric.2005.12.002

DO - 10.1016/j.mric.2005.12.002

M3 - Review article

C2 - 16530635

AN - SCOPUS:33644839187

VL - 14

SP - 63

EP - 76

JO - Magnetic Resonance Imaging Clinics of North America

JF - Magnetic Resonance Imaging Clinics of North America

SN - 1064-9689

IS - 1

ER -