Pipe testing with ultrasonic guided wave synthetic focusing techniques

Jing Mu, Li Zhang, Jia Hua, Joseph Lawrence Rose

Research output: Contribution to specialist publicationArticle

3 Citations (Scopus)

Abstract

Ultrasonic guided waves are routinely incorporated by industries for pipeline testing. Both guided wave energy tuning upon excitation and signal interpretation upon reception are important for discontinuity detection in pipes. Active phased array systems for long-range pipe inspection are available. Choosing active phased array or synthetic focusing is often necessary for improved testing speed, as well as overall penetration power. In this paper, two synthetic focusing techniques were utilized for discontinuity detection in a pipe. One synthetic focusing technique used time delays, while the other technique utilized a mode extraction and backpropagation scheme. Synthetic focusing techniques use either axisymmetric loading or partial loadings to generate guided waves and receive the waves by individual segments. Synthetic focusing is achieved by data analysis of the received signals, so it is faster to carry out a total focal scan for a pipeline by employing a synthetic focusing technique than by using the active focusing technique. This study shows that the time delay synthetic focusing technique yielded more accurate results for discontinuity detection and localization in a 101.6 mm steel pipe with four channels, while the back-propagation technique gave better discontinuity imaging results of a 203.2 mm steel pipe with eight channels. Both methods are useful.

Original languageEnglish (US)
Pages1171-1176
Number of pages6
Volume68
No10
Specialist publicationMaterials Evaluation
StatePublished - Oct 1 2010

Fingerprint

Guided electromagnetic wave propagation
Ultrasonic waves
Pipe
Testing
Steel pipe
Backpropagation
Time delay
Pipelines
Tuning
Inspection
Imaging techniques

All Science Journal Classification (ASJC) codes

  • Materials Science(all)
  • Mechanics of Materials
  • Mechanical Engineering

Cite this

Mu, J., Zhang, L., Hua, J., & Rose, J. L. (2010). Pipe testing with ultrasonic guided wave synthetic focusing techniques. Materials Evaluation, 68(10), 1171-1176.
Mu, Jing ; Zhang, Li ; Hua, Jia ; Rose, Joseph Lawrence. / Pipe testing with ultrasonic guided wave synthetic focusing techniques. In: Materials Evaluation. 2010 ; Vol. 68, No. 10. pp. 1171-1176.
@misc{59d884b0b4744b36b25fe9c0964c900e,
title = "Pipe testing with ultrasonic guided wave synthetic focusing techniques",
abstract = "Ultrasonic guided waves are routinely incorporated by industries for pipeline testing. Both guided wave energy tuning upon excitation and signal interpretation upon reception are important for discontinuity detection in pipes. Active phased array systems for long-range pipe inspection are available. Choosing active phased array or synthetic focusing is often necessary for improved testing speed, as well as overall penetration power. In this paper, two synthetic focusing techniques were utilized for discontinuity detection in a pipe. One synthetic focusing technique used time delays, while the other technique utilized a mode extraction and backpropagation scheme. Synthetic focusing techniques use either axisymmetric loading or partial loadings to generate guided waves and receive the waves by individual segments. Synthetic focusing is achieved by data analysis of the received signals, so it is faster to carry out a total focal scan for a pipeline by employing a synthetic focusing technique than by using the active focusing technique. This study shows that the time delay synthetic focusing technique yielded more accurate results for discontinuity detection and localization in a 101.6 mm steel pipe with four channels, while the back-propagation technique gave better discontinuity imaging results of a 203.2 mm steel pipe with eight channels. Both methods are useful.",
author = "Jing Mu and Li Zhang and Jia Hua and Rose, {Joseph Lawrence}",
year = "2010",
month = "10",
day = "1",
language = "English (US)",
volume = "68",
pages = "1171--1176",
journal = "Materials Evaluation",
issn = "0025-5327",
publisher = "American Society for Nondestructive Testing",

}

Mu, J, Zhang, L, Hua, J & Rose, JL 2010, 'Pipe testing with ultrasonic guided wave synthetic focusing techniques' Materials Evaluation, vol. 68, no. 10, pp. 1171-1176.

Pipe testing with ultrasonic guided wave synthetic focusing techniques. / Mu, Jing; Zhang, Li; Hua, Jia; Rose, Joseph Lawrence.

In: Materials Evaluation, Vol. 68, No. 10, 01.10.2010, p. 1171-1176.

Research output: Contribution to specialist publicationArticle

TY - GEN

T1 - Pipe testing with ultrasonic guided wave synthetic focusing techniques

AU - Mu, Jing

AU - Zhang, Li

AU - Hua, Jia

AU - Rose, Joseph Lawrence

PY - 2010/10/1

Y1 - 2010/10/1

N2 - Ultrasonic guided waves are routinely incorporated by industries for pipeline testing. Both guided wave energy tuning upon excitation and signal interpretation upon reception are important for discontinuity detection in pipes. Active phased array systems for long-range pipe inspection are available. Choosing active phased array or synthetic focusing is often necessary for improved testing speed, as well as overall penetration power. In this paper, two synthetic focusing techniques were utilized for discontinuity detection in a pipe. One synthetic focusing technique used time delays, while the other technique utilized a mode extraction and backpropagation scheme. Synthetic focusing techniques use either axisymmetric loading or partial loadings to generate guided waves and receive the waves by individual segments. Synthetic focusing is achieved by data analysis of the received signals, so it is faster to carry out a total focal scan for a pipeline by employing a synthetic focusing technique than by using the active focusing technique. This study shows that the time delay synthetic focusing technique yielded more accurate results for discontinuity detection and localization in a 101.6 mm steel pipe with four channels, while the back-propagation technique gave better discontinuity imaging results of a 203.2 mm steel pipe with eight channels. Both methods are useful.

AB - Ultrasonic guided waves are routinely incorporated by industries for pipeline testing. Both guided wave energy tuning upon excitation and signal interpretation upon reception are important for discontinuity detection in pipes. Active phased array systems for long-range pipe inspection are available. Choosing active phased array or synthetic focusing is often necessary for improved testing speed, as well as overall penetration power. In this paper, two synthetic focusing techniques were utilized for discontinuity detection in a pipe. One synthetic focusing technique used time delays, while the other technique utilized a mode extraction and backpropagation scheme. Synthetic focusing techniques use either axisymmetric loading or partial loadings to generate guided waves and receive the waves by individual segments. Synthetic focusing is achieved by data analysis of the received signals, so it is faster to carry out a total focal scan for a pipeline by employing a synthetic focusing technique than by using the active focusing technique. This study shows that the time delay synthetic focusing technique yielded more accurate results for discontinuity detection and localization in a 101.6 mm steel pipe with four channels, while the back-propagation technique gave better discontinuity imaging results of a 203.2 mm steel pipe with eight channels. Both methods are useful.

UR - http://www.scopus.com/inward/record.url?scp=78649936789&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=78649936789&partnerID=8YFLogxK

M3 - Article

VL - 68

SP - 1171

EP - 1176

JO - Materials Evaluation

JF - Materials Evaluation

SN - 0025-5327

ER -

Mu J, Zhang L, Hua J, Rose JL. Pipe testing with ultrasonic guided wave synthetic focusing techniques. Materials Evaluation. 2010 Oct 1;68(10):1171-1176.