Prediction of pork quality characteristics using visible and near-infrared spectroscopy

Diane E. Chan, Paul N. Walker, Edward William Mills

Research output: Contribution to journalArticle

55 Citations (Scopus)

Abstract

Visible/near-infrared (Vis/NIR) spectroscopy was tested as a non-destructive method to assess the quality of fresh pork loin. Quality characteristics of pork were measured to develop calibration models for a diode-array Vis/NIR reflectance spectrophotometer. Spectral measurements and measurements for pH, water-holding capacity (WHC), XYZ tristimulus values, cook yield, shear force, proximate analysis (moisture, fat, and protein content), and subjective color, marbling, and firmness scores were performed for 411 fresh pork loin samples. Approximately 80% of the Sample set was used for calibration and 20% for validation. Partial least squares (PLS) Calibration models were developed for each characteristic measured. XYZ tristimulus values were predicted well with R2 > 0.91 and SECV < 0.96 for calibration, and R2 > 0.88 and SEP ≤ 1.2 for validation. Moisture, fat, and protein content were predicted less well with R2 > 0.69 and SECV < 0.007 for calibration, and R2 > 0.61 and SEP < 0.007 for validation. The calibrations for the other characteristics (shear force, cook yield, pH, water-holding capacity, and scores for color, marbling, and firmness) varied from marginally good to poor with R2 values ranging from 0.584 to 0.002.

Original languageEnglish (US)
Pages (from-to)1519-1527
Number of pages9
JournalTransactions of the American Society of Agricultural Engineers
Volume45
Issue number5
StatePublished - Sep 2002

Fingerprint

Near infrared spectroscopy
Near-Infrared Spectroscopy
near-infrared spectroscopy
infrared spectroscopy
meat quality
Calibration
near infrared
calibration
pork
prediction
marbling
loins
Oils and fats
water holding capacity
fat
shears
firmness
Moisture
Color
Fats

All Science Journal Classification (ASJC) codes

  • Agricultural and Biological Sciences (miscellaneous)

Cite this

@article{e224905ca99644b6af22fb0384edbd26,
title = "Prediction of pork quality characteristics using visible and near-infrared spectroscopy",
abstract = "Visible/near-infrared (Vis/NIR) spectroscopy was tested as a non-destructive method to assess the quality of fresh pork loin. Quality characteristics of pork were measured to develop calibration models for a diode-array Vis/NIR reflectance spectrophotometer. Spectral measurements and measurements for pH, water-holding capacity (WHC), XYZ tristimulus values, cook yield, shear force, proximate analysis (moisture, fat, and protein content), and subjective color, marbling, and firmness scores were performed for 411 fresh pork loin samples. Approximately 80{\%} of the Sample set was used for calibration and 20{\%} for validation. Partial least squares (PLS) Calibration models were developed for each characteristic measured. XYZ tristimulus values were predicted well with R2 > 0.91 and SECV < 0.96 for calibration, and R2 > 0.88 and SEP ≤ 1.2 for validation. Moisture, fat, and protein content were predicted less well with R2 > 0.69 and SECV < 0.007 for calibration, and R2 > 0.61 and SEP < 0.007 for validation. The calibrations for the other characteristics (shear force, cook yield, pH, water-holding capacity, and scores for color, marbling, and firmness) varied from marginally good to poor with R2 values ranging from 0.584 to 0.002.",
author = "Chan, {Diane E.} and Walker, {Paul N.} and Mills, {Edward William}",
year = "2002",
month = "9",
language = "English (US)",
volume = "45",
pages = "1519--1527",
journal = "Transactions of the ASABE",
issn = "2151-0032",
publisher = "American Society of Agricultural and Biological Engineers",
number = "5",

}

Prediction of pork quality characteristics using visible and near-infrared spectroscopy. / Chan, Diane E.; Walker, Paul N.; Mills, Edward William.

In: Transactions of the American Society of Agricultural Engineers, Vol. 45, No. 5, 09.2002, p. 1519-1527.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Prediction of pork quality characteristics using visible and near-infrared spectroscopy

AU - Chan, Diane E.

AU - Walker, Paul N.

AU - Mills, Edward William

PY - 2002/9

Y1 - 2002/9

N2 - Visible/near-infrared (Vis/NIR) spectroscopy was tested as a non-destructive method to assess the quality of fresh pork loin. Quality characteristics of pork were measured to develop calibration models for a diode-array Vis/NIR reflectance spectrophotometer. Spectral measurements and measurements for pH, water-holding capacity (WHC), XYZ tristimulus values, cook yield, shear force, proximate analysis (moisture, fat, and protein content), and subjective color, marbling, and firmness scores were performed for 411 fresh pork loin samples. Approximately 80% of the Sample set was used for calibration and 20% for validation. Partial least squares (PLS) Calibration models were developed for each characteristic measured. XYZ tristimulus values were predicted well with R2 > 0.91 and SECV < 0.96 for calibration, and R2 > 0.88 and SEP ≤ 1.2 for validation. Moisture, fat, and protein content were predicted less well with R2 > 0.69 and SECV < 0.007 for calibration, and R2 > 0.61 and SEP < 0.007 for validation. The calibrations for the other characteristics (shear force, cook yield, pH, water-holding capacity, and scores for color, marbling, and firmness) varied from marginally good to poor with R2 values ranging from 0.584 to 0.002.

AB - Visible/near-infrared (Vis/NIR) spectroscopy was tested as a non-destructive method to assess the quality of fresh pork loin. Quality characteristics of pork were measured to develop calibration models for a diode-array Vis/NIR reflectance spectrophotometer. Spectral measurements and measurements for pH, water-holding capacity (WHC), XYZ tristimulus values, cook yield, shear force, proximate analysis (moisture, fat, and protein content), and subjective color, marbling, and firmness scores were performed for 411 fresh pork loin samples. Approximately 80% of the Sample set was used for calibration and 20% for validation. Partial least squares (PLS) Calibration models were developed for each characteristic measured. XYZ tristimulus values were predicted well with R2 > 0.91 and SECV < 0.96 for calibration, and R2 > 0.88 and SEP ≤ 1.2 for validation. Moisture, fat, and protein content were predicted less well with R2 > 0.69 and SECV < 0.007 for calibration, and R2 > 0.61 and SEP < 0.007 for validation. The calibrations for the other characteristics (shear force, cook yield, pH, water-holding capacity, and scores for color, marbling, and firmness) varied from marginally good to poor with R2 values ranging from 0.584 to 0.002.

UR - http://www.scopus.com/inward/record.url?scp=0036766842&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0036766842&partnerID=8YFLogxK

M3 - Article

VL - 45

SP - 1519

EP - 1527

JO - Transactions of the ASABE

JF - Transactions of the ASABE

SN - 2151-0032

IS - 5

ER -