Protein-membrane interactions during hemodialysis: Effects on solute transport

Stavroula M. Morti, Andrew L. Zydney

Research output: Contribution to journalArticle

Abstract

Although several previous studies have shown that plasma protein adsorption can reduce solute clearance during hemodialysis, there is currently no quantitative understanding of the factors that govern the extent of these protein-membrane interactions. In this study, quantitative data were obtained for the clearance of urea, vitamin B12, and polydisperse dextrans using polyacrylonitrile (AN69) and cellulose triacetate dialyzers before and after exposure to human plasma in a simulated dialysis session. Contact with plasma had little effect on clearance of urea and vitamin B12, but caused more than an order of magnitude reduction in clearance for solutes with molecular weights >10,000. These data were analyzed using a two layer model in which contact with plasma was assumed to cause a thin protein layer to form on the surface of the membrane. The protein layer had an effective pore size of ≈12 angstroms, and was ≈1 μm thick, as determined by a hydrodynamic analysis of the clearance data, and from independent estimates based on changes in fiber bundle volume and ultrafiltration coefficient. The thickness of the protein layer increased with increasing dialysis time, ranging from 0.25 μm after 40 min to 0.86 μm after 180 min. These results provide important insights into the effects of contact with plasma on solute clearance during hemodialysis.

Original languageEnglish (US)
Pages (from-to)319-326
Number of pages8
JournalASAIO Journal
Volume44
Issue number4
DOIs
StatePublished - Jan 1 1998

Fingerprint

Solute transport
Renal Dialysis
Membrane Proteins
Dialysis
Vitamin B 12
Proteins
Membranes
Plasmas
Urea
Vitamins
Plasma (human)
Ultrafiltration
Dextrans
Pore size
Blood Proteins
Hydrodynamics
Molecular weight
Dextran
Adsorption
Polyacrylonitriles

All Science Journal Classification (ASJC) codes

  • Biophysics
  • Bioengineering
  • Biomaterials
  • Biomedical Engineering

Cite this

@article{8ec62755b8b645f4bed4c95e470db583,
title = "Protein-membrane interactions during hemodialysis: Effects on solute transport",
abstract = "Although several previous studies have shown that plasma protein adsorption can reduce solute clearance during hemodialysis, there is currently no quantitative understanding of the factors that govern the extent of these protein-membrane interactions. In this study, quantitative data were obtained for the clearance of urea, vitamin B12, and polydisperse dextrans using polyacrylonitrile (AN69) and cellulose triacetate dialyzers before and after exposure to human plasma in a simulated dialysis session. Contact with plasma had little effect on clearance of urea and vitamin B12, but caused more than an order of magnitude reduction in clearance for solutes with molecular weights >10,000. These data were analyzed using a two layer model in which contact with plasma was assumed to cause a thin protein layer to form on the surface of the membrane. The protein layer had an effective pore size of ≈12 angstroms, and was ≈1 μm thick, as determined by a hydrodynamic analysis of the clearance data, and from independent estimates based on changes in fiber bundle volume and ultrafiltration coefficient. The thickness of the protein layer increased with increasing dialysis time, ranging from 0.25 μm after 40 min to 0.86 μm after 180 min. These results provide important insights into the effects of contact with plasma on solute clearance during hemodialysis.",
author = "Morti, {Stavroula M.} and Zydney, {Andrew L.}",
year = "1998",
month = "1",
day = "1",
doi = "10.1097/00002480-199807000-00015",
language = "English (US)",
volume = "44",
pages = "319--326",
journal = "ASAIO Journal",
issn = "1058-2916",
publisher = "Lippincott Williams and Wilkins",
number = "4",

}

Protein-membrane interactions during hemodialysis : Effects on solute transport. / Morti, Stavroula M.; Zydney, Andrew L.

In: ASAIO Journal, Vol. 44, No. 4, 01.01.1998, p. 319-326.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Protein-membrane interactions during hemodialysis

T2 - Effects on solute transport

AU - Morti, Stavroula M.

AU - Zydney, Andrew L.

PY - 1998/1/1

Y1 - 1998/1/1

N2 - Although several previous studies have shown that plasma protein adsorption can reduce solute clearance during hemodialysis, there is currently no quantitative understanding of the factors that govern the extent of these protein-membrane interactions. In this study, quantitative data were obtained for the clearance of urea, vitamin B12, and polydisperse dextrans using polyacrylonitrile (AN69) and cellulose triacetate dialyzers before and after exposure to human plasma in a simulated dialysis session. Contact with plasma had little effect on clearance of urea and vitamin B12, but caused more than an order of magnitude reduction in clearance for solutes with molecular weights >10,000. These data were analyzed using a two layer model in which contact with plasma was assumed to cause a thin protein layer to form on the surface of the membrane. The protein layer had an effective pore size of ≈12 angstroms, and was ≈1 μm thick, as determined by a hydrodynamic analysis of the clearance data, and from independent estimates based on changes in fiber bundle volume and ultrafiltration coefficient. The thickness of the protein layer increased with increasing dialysis time, ranging from 0.25 μm after 40 min to 0.86 μm after 180 min. These results provide important insights into the effects of contact with plasma on solute clearance during hemodialysis.

AB - Although several previous studies have shown that plasma protein adsorption can reduce solute clearance during hemodialysis, there is currently no quantitative understanding of the factors that govern the extent of these protein-membrane interactions. In this study, quantitative data were obtained for the clearance of urea, vitamin B12, and polydisperse dextrans using polyacrylonitrile (AN69) and cellulose triacetate dialyzers before and after exposure to human plasma in a simulated dialysis session. Contact with plasma had little effect on clearance of urea and vitamin B12, but caused more than an order of magnitude reduction in clearance for solutes with molecular weights >10,000. These data were analyzed using a two layer model in which contact with plasma was assumed to cause a thin protein layer to form on the surface of the membrane. The protein layer had an effective pore size of ≈12 angstroms, and was ≈1 μm thick, as determined by a hydrodynamic analysis of the clearance data, and from independent estimates based on changes in fiber bundle volume and ultrafiltration coefficient. The thickness of the protein layer increased with increasing dialysis time, ranging from 0.25 μm after 40 min to 0.86 μm after 180 min. These results provide important insights into the effects of contact with plasma on solute clearance during hemodialysis.

UR - http://www.scopus.com/inward/record.url?scp=0344541871&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0344541871&partnerID=8YFLogxK

U2 - 10.1097/00002480-199807000-00015

DO - 10.1097/00002480-199807000-00015

M3 - Article

C2 - 9682960

VL - 44

SP - 319

EP - 326

JO - ASAIO Journal

JF - ASAIO Journal

SN - 1058-2916

IS - 4

ER -