Monitorage de la saturation de pouls: Intérêts et limites

Translated title of the contribution: Pulse oximetry's monitoring: Advantages and limits

J. Pottecher, G. Bouzou, Andry Van De Louw

Research output: Contribution to journalShort survey

4 Citations (Scopus)

Abstract

Pulse oximetry is a standard monitoring device in intensive care and post-anesthesia care units, currently used to guide therapeutic interventions. Nevertheless, the accuracy of pulse oximetry in critical care patients has been poorly studied, and no beneficial effect on morbidity or mortality has been demonstrated. The cost-effectiveness of oximeters has also not been demonstrated. Conversely, several studies showed that the agreement between pulse oximetry and the arterial oxygen saturation, although within the limits ensured by the manufacturers, may not be clinically sufficient, especially in the most unstable patients. Thus, the clinicians should be aware of the advantages and limits of the pulse oximetry, to use it carefully and to avoid unrecognised hypoxemia associated with low SpO 2 targets.

Original languageFrench
Pages (from-to)30-36
Number of pages7
JournalReanimation
Volume12
Issue number1
DOIs
StatePublished - Jan 1 2003

Fingerprint

Oximetry
Critical Care
Cost-Benefit Analysis
Anesthesia
Oxygen
Morbidity
Equipment and Supplies
Mortality
Therapeutics

All Science Journal Classification (ASJC) codes

  • Emergency Medicine
  • Emergency

Cite this

Pottecher, J. ; Bouzou, G. ; Van De Louw, Andry. / Monitorage de la saturation de pouls : Intérêts et limites. In: Reanimation. 2003 ; Vol. 12, No. 1. pp. 30-36.
@article{e40b7f4c8cda44a0b2880c9e42e1bef6,
title = "Monitorage de la saturation de pouls: Int{\'e}r{\^e}ts et limites",
abstract = "Pulse oximetry is a standard monitoring device in intensive care and post-anesthesia care units, currently used to guide therapeutic interventions. Nevertheless, the accuracy of pulse oximetry in critical care patients has been poorly studied, and no beneficial effect on morbidity or mortality has been demonstrated. The cost-effectiveness of oximeters has also not been demonstrated. Conversely, several studies showed that the agreement between pulse oximetry and the arterial oxygen saturation, although within the limits ensured by the manufacturers, may not be clinically sufficient, especially in the most unstable patients. Thus, the clinicians should be aware of the advantages and limits of the pulse oximetry, to use it carefully and to avoid unrecognised hypoxemia associated with low SpO 2 targets.",
author = "J. Pottecher and G. Bouzou and {Van De Louw}, Andry",
year = "2003",
month = "1",
day = "1",
doi = "10.1016/S1624-0693(02)00006-3",
language = "French",
volume = "12",
pages = "30--36",
journal = "Reanimation",
issn = "1624-0693",
publisher = "Elsevier Masson SAS",
number = "1",

}

Monitorage de la saturation de pouls : Intérêts et limites. / Pottecher, J.; Bouzou, G.; Van De Louw, Andry.

In: Reanimation, Vol. 12, No. 1, 01.01.2003, p. 30-36.

Research output: Contribution to journalShort survey

TY - JOUR

T1 - Monitorage de la saturation de pouls

T2 - Intérêts et limites

AU - Pottecher, J.

AU - Bouzou, G.

AU - Van De Louw, Andry

PY - 2003/1/1

Y1 - 2003/1/1

N2 - Pulse oximetry is a standard monitoring device in intensive care and post-anesthesia care units, currently used to guide therapeutic interventions. Nevertheless, the accuracy of pulse oximetry in critical care patients has been poorly studied, and no beneficial effect on morbidity or mortality has been demonstrated. The cost-effectiveness of oximeters has also not been demonstrated. Conversely, several studies showed that the agreement between pulse oximetry and the arterial oxygen saturation, although within the limits ensured by the manufacturers, may not be clinically sufficient, especially in the most unstable patients. Thus, the clinicians should be aware of the advantages and limits of the pulse oximetry, to use it carefully and to avoid unrecognised hypoxemia associated with low SpO 2 targets.

AB - Pulse oximetry is a standard monitoring device in intensive care and post-anesthesia care units, currently used to guide therapeutic interventions. Nevertheless, the accuracy of pulse oximetry in critical care patients has been poorly studied, and no beneficial effect on morbidity or mortality has been demonstrated. The cost-effectiveness of oximeters has also not been demonstrated. Conversely, several studies showed that the agreement between pulse oximetry and the arterial oxygen saturation, although within the limits ensured by the manufacturers, may not be clinically sufficient, especially in the most unstable patients. Thus, the clinicians should be aware of the advantages and limits of the pulse oximetry, to use it carefully and to avoid unrecognised hypoxemia associated with low SpO 2 targets.

UR - http://www.scopus.com/inward/record.url?scp=0037240210&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0037240210&partnerID=8YFLogxK

U2 - 10.1016/S1624-0693(02)00006-3

DO - 10.1016/S1624-0693(02)00006-3

M3 - Short survey

AN - SCOPUS:0037240210

VL - 12

SP - 30

EP - 36

JO - Reanimation

JF - Reanimation

SN - 1624-0693

IS - 1

ER -