Reliability and validity of a 2-D video digitizing system during a static and a dynamic task

Phillip Gribble, Jay Hertel, Craig Denegar, William E. Buckley

Research output: Contribution to journalArticle

12 Citations (Scopus)

Abstract

Context: The SMART™ software system offers low-cost kinematic analysis through digitization of video from a single camera. The reliability and validity of this product have not been reported. Objective: To assess the reliability and validity of the SMART software during a simple static task and dynamic task. Design: Test-retest to compare assumed neutral and goniometrically measured joint angles in the sagittal plane of the lower extremity. Setting: Research laboratory. Participants: 7 in a static task, 16 young, physically active in a dynamic task. Results: Measurement error of the SMART system ranged from 0.29° ± 1.98° to 11.07° ± 1.77°. The interrater reliability (ICC2,1) values ranged from .60 to .92 for the static task and from .76 to .89 for the dynamic task. Conclusions: Based on the results of both studies, the SMART system offers a low-cost alternative for reporting single-plane kinematics during an individual frame of video during static stances and slow dynamic tasks with strong reliability and reasonable validity.

Original languageEnglish (US)
Pages (from-to)137-149
Number of pages13
JournalJournal of Sport Rehabilitation
Volume14
Issue number2
DOIs
StatePublished - Jan 1 2005

Fingerprint

Reproducibility of Results
Biomechanical Phenomena
Software
Costs and Cost Analysis
Lower Extremity
Joints
Research

All Science Journal Classification (ASJC) codes

  • Biophysics
  • Orthopedics and Sports Medicine
  • Physical Therapy, Sports Therapy and Rehabilitation
  • Rehabilitation

Cite this

@article{199875b531194124a05a2ae8da762ff5,
title = "Reliability and validity of a 2-D video digitizing system during a static and a dynamic task",
abstract = "Context: The SMART™ software system offers low-cost kinematic analysis through digitization of video from a single camera. The reliability and validity of this product have not been reported. Objective: To assess the reliability and validity of the SMART software during a simple static task and dynamic task. Design: Test-retest to compare assumed neutral and goniometrically measured joint angles in the sagittal plane of the lower extremity. Setting: Research laboratory. Participants: 7 in a static task, 16 young, physically active in a dynamic task. Results: Measurement error of the SMART system ranged from 0.29° ± 1.98° to 11.07° ± 1.77°. The interrater reliability (ICC2,1) values ranged from .60 to .92 for the static task and from .76 to .89 for the dynamic task. Conclusions: Based on the results of both studies, the SMART system offers a low-cost alternative for reporting single-plane kinematics during an individual frame of video during static stances and slow dynamic tasks with strong reliability and reasonable validity.",
author = "Phillip Gribble and Jay Hertel and Craig Denegar and Buckley, {William E.}",
year = "2005",
month = "1",
day = "1",
doi = "10.1123/jsr.14.2.137",
language = "English (US)",
volume = "14",
pages = "137--149",
journal = "Journal of Sport Rehabilitation",
issn = "1056-6716",
publisher = "Human Kinetics Publishers Inc.",
number = "2",

}

Reliability and validity of a 2-D video digitizing system during a static and a dynamic task. / Gribble, Phillip; Hertel, Jay; Denegar, Craig; Buckley, William E.

In: Journal of Sport Rehabilitation, Vol. 14, No. 2, 01.01.2005, p. 137-149.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Reliability and validity of a 2-D video digitizing system during a static and a dynamic task

AU - Gribble, Phillip

AU - Hertel, Jay

AU - Denegar, Craig

AU - Buckley, William E.

PY - 2005/1/1

Y1 - 2005/1/1

N2 - Context: The SMART™ software system offers low-cost kinematic analysis through digitization of video from a single camera. The reliability and validity of this product have not been reported. Objective: To assess the reliability and validity of the SMART software during a simple static task and dynamic task. Design: Test-retest to compare assumed neutral and goniometrically measured joint angles in the sagittal plane of the lower extremity. Setting: Research laboratory. Participants: 7 in a static task, 16 young, physically active in a dynamic task. Results: Measurement error of the SMART system ranged from 0.29° ± 1.98° to 11.07° ± 1.77°. The interrater reliability (ICC2,1) values ranged from .60 to .92 for the static task and from .76 to .89 for the dynamic task. Conclusions: Based on the results of both studies, the SMART system offers a low-cost alternative for reporting single-plane kinematics during an individual frame of video during static stances and slow dynamic tasks with strong reliability and reasonable validity.

AB - Context: The SMART™ software system offers low-cost kinematic analysis through digitization of video from a single camera. The reliability and validity of this product have not been reported. Objective: To assess the reliability and validity of the SMART software during a simple static task and dynamic task. Design: Test-retest to compare assumed neutral and goniometrically measured joint angles in the sagittal plane of the lower extremity. Setting: Research laboratory. Participants: 7 in a static task, 16 young, physically active in a dynamic task. Results: Measurement error of the SMART system ranged from 0.29° ± 1.98° to 11.07° ± 1.77°. The interrater reliability (ICC2,1) values ranged from .60 to .92 for the static task and from .76 to .89 for the dynamic task. Conclusions: Based on the results of both studies, the SMART system offers a low-cost alternative for reporting single-plane kinematics during an individual frame of video during static stances and slow dynamic tasks with strong reliability and reasonable validity.

UR - http://www.scopus.com/inward/record.url?scp=18844382124&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=18844382124&partnerID=8YFLogxK

U2 - 10.1123/jsr.14.2.137

DO - 10.1123/jsr.14.2.137

M3 - Article

AN - SCOPUS:18844382124

VL - 14

SP - 137

EP - 149

JO - Journal of Sport Rehabilitation

JF - Journal of Sport Rehabilitation

SN - 1056-6716

IS - 2