Investigation of the spatial distribution of lipids in cell membranes can lead to an improved understanding of the role of lipids in biological function and disease. Time-of-flight secondary ion mass spectrometry is capable of molecule-specific imaging of biological molecules across single cells and has demonstrated potential for examining the functional segregation of lipids in cell membranes. In this paper, standard SIMS spectra are analyzed for phosphatidylethanolamine, phosphatidylglycerol, phosphatidylserine, phosphatidylinositol, cholesterol, and sulfatide. Importantly, each of the lipids result in signature mass spectral peaks that allow them to be identified. These signature peaks are also useful for imaging experiments and are utilized here to simultaneously image lipids on a micrometer scale in picoliter vials. Because the low secondary ion signal achieved for lipids from an atomic primary ion source makes cell-imaging experiments challenging, improving signal with cluster primary ion sources is of interest. Here, we compare the secondary ion yield for seven lipids using atomic (Ga + or In +) ion sources and a buckminsterfullerene (C 60 +) primary ion source. A 40-1000-fold improvement in signal is found with C 60 + relative to the other two ion sources, indicating great promise for future cellular imaging applications using the C 60 + probe.

Original languageEnglish (US)
Pages (from-to)6190-6196
Number of pages7
JournalAnalytical Chemistry
Volume77
Issue number19
DOIs
StatePublished - Oct 1 2005

Fingerprint

Fullerenes
Ion sources
Ions
Lipids
Imaging techniques
Cell membranes
Secondary ion mass spectrometry
Phosphatidylglycerols
Molecules
Phosphatidylserines
Phosphatidylinositols
Spatial distribution
Experiments

All Science Journal Classification (ASJC) codes

  • Analytical Chemistry

Cite this

Ostrowski, S. G., Szakal, C., Kozole, J., Roddy, T. P., Xu, J., Ewing, A. G., & Winograd, N. (2005). Secondary ion MS imaging of lipids in picoliter vials with a buckminsterfullerene ion source. Analytical Chemistry, 77(19), 6190-6196. https://doi.org/10.1021/ac0508189
Ostrowski, Sara G. ; Szakal, Christopher ; Kozole, Joseph ; Roddy, Thomas P. ; Xu, Jiyun ; Ewing, Andrew G. ; Winograd, Nicholas. / Secondary ion MS imaging of lipids in picoliter vials with a buckminsterfullerene ion source. In: Analytical Chemistry. 2005 ; Vol. 77, No. 19. pp. 6190-6196.
@article{889584e63b7e4d83b8876db8fb308afb,
title = "Secondary ion MS imaging of lipids in picoliter vials with a buckminsterfullerene ion source",
abstract = "Investigation of the spatial distribution of lipids in cell membranes can lead to an improved understanding of the role of lipids in biological function and disease. Time-of-flight secondary ion mass spectrometry is capable of molecule-specific imaging of biological molecules across single cells and has demonstrated potential for examining the functional segregation of lipids in cell membranes. In this paper, standard SIMS spectra are analyzed for phosphatidylethanolamine, phosphatidylglycerol, phosphatidylserine, phosphatidylinositol, cholesterol, and sulfatide. Importantly, each of the lipids result in signature mass spectral peaks that allow them to be identified. These signature peaks are also useful for imaging experiments and are utilized here to simultaneously image lipids on a micrometer scale in picoliter vials. Because the low secondary ion signal achieved for lipids from an atomic primary ion source makes cell-imaging experiments challenging, improving signal with cluster primary ion sources is of interest. Here, we compare the secondary ion yield for seven lipids using atomic (Ga + or In +) ion sources and a buckminsterfullerene (C 60 +) primary ion source. A 40-1000-fold improvement in signal is found with C 60 + relative to the other two ion sources, indicating great promise for future cellular imaging applications using the C 60 + probe.",
author = "Ostrowski, {Sara G.} and Christopher Szakal and Joseph Kozole and Roddy, {Thomas P.} and Jiyun Xu and Ewing, {Andrew G.} and Nicholas Winograd",
year = "2005",
month = "10",
day = "1",
doi = "10.1021/ac0508189",
language = "English (US)",
volume = "77",
pages = "6190--6196",
journal = "Analytical Chemistry",
issn = "0003-2700",
publisher = "American Chemical Society",
number = "19",

}

Ostrowski, SG, Szakal, C, Kozole, J, Roddy, TP, Xu, J, Ewing, AG & Winograd, N 2005, 'Secondary ion MS imaging of lipids in picoliter vials with a buckminsterfullerene ion source', Analytical Chemistry, vol. 77, no. 19, pp. 6190-6196. https://doi.org/10.1021/ac0508189

Secondary ion MS imaging of lipids in picoliter vials with a buckminsterfullerene ion source. / Ostrowski, Sara G.; Szakal, Christopher; Kozole, Joseph; Roddy, Thomas P.; Xu, Jiyun; Ewing, Andrew G.; Winograd, Nicholas.

In: Analytical Chemistry, Vol. 77, No. 19, 01.10.2005, p. 6190-6196.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Secondary ion MS imaging of lipids in picoliter vials with a buckminsterfullerene ion source

AU - Ostrowski, Sara G.

AU - Szakal, Christopher

AU - Kozole, Joseph

AU - Roddy, Thomas P.

AU - Xu, Jiyun

AU - Ewing, Andrew G.

AU - Winograd, Nicholas

PY - 2005/10/1

Y1 - 2005/10/1

N2 - Investigation of the spatial distribution of lipids in cell membranes can lead to an improved understanding of the role of lipids in biological function and disease. Time-of-flight secondary ion mass spectrometry is capable of molecule-specific imaging of biological molecules across single cells and has demonstrated potential for examining the functional segregation of lipids in cell membranes. In this paper, standard SIMS spectra are analyzed for phosphatidylethanolamine, phosphatidylglycerol, phosphatidylserine, phosphatidylinositol, cholesterol, and sulfatide. Importantly, each of the lipids result in signature mass spectral peaks that allow them to be identified. These signature peaks are also useful for imaging experiments and are utilized here to simultaneously image lipids on a micrometer scale in picoliter vials. Because the low secondary ion signal achieved for lipids from an atomic primary ion source makes cell-imaging experiments challenging, improving signal with cluster primary ion sources is of interest. Here, we compare the secondary ion yield for seven lipids using atomic (Ga + or In +) ion sources and a buckminsterfullerene (C 60 +) primary ion source. A 40-1000-fold improvement in signal is found with C 60 + relative to the other two ion sources, indicating great promise for future cellular imaging applications using the C 60 + probe.

AB - Investigation of the spatial distribution of lipids in cell membranes can lead to an improved understanding of the role of lipids in biological function and disease. Time-of-flight secondary ion mass spectrometry is capable of molecule-specific imaging of biological molecules across single cells and has demonstrated potential for examining the functional segregation of lipids in cell membranes. In this paper, standard SIMS spectra are analyzed for phosphatidylethanolamine, phosphatidylglycerol, phosphatidylserine, phosphatidylinositol, cholesterol, and sulfatide. Importantly, each of the lipids result in signature mass spectral peaks that allow them to be identified. These signature peaks are also useful for imaging experiments and are utilized here to simultaneously image lipids on a micrometer scale in picoliter vials. Because the low secondary ion signal achieved for lipids from an atomic primary ion source makes cell-imaging experiments challenging, improving signal with cluster primary ion sources is of interest. Here, we compare the secondary ion yield for seven lipids using atomic (Ga + or In +) ion sources and a buckminsterfullerene (C 60 +) primary ion source. A 40-1000-fold improvement in signal is found with C 60 + relative to the other two ion sources, indicating great promise for future cellular imaging applications using the C 60 + probe.

UR - http://www.scopus.com/inward/record.url?scp=26444447581&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=26444447581&partnerID=8YFLogxK

U2 - 10.1021/ac0508189

DO - 10.1021/ac0508189

M3 - Article

C2 - 16194078

AN - SCOPUS:26444447581

VL - 77

SP - 6190

EP - 6196

JO - Analytical Chemistry

JF - Analytical Chemistry

SN - 0003-2700

IS - 19

ER -

Ostrowski SG, Szakal C, Kozole J, Roddy TP, Xu J, Ewing AG et al. Secondary ion MS imaging of lipids in picoliter vials with a buckminsterfullerene ion source. Analytical Chemistry. 2005 Oct 1;77(19):6190-6196. https://doi.org/10.1021/ac0508189